文献速递外周血管胸部腹部CT

双能CT后处理鉴别静脉血栓与碘流伪影的影响

Impact of dual-energy CT post-processing to differentiate venous thrombosis from iodine flux artefacts.
PubMed 文献 · Eur Radiol · 2018-06-04

本研究纳入99例在增强CT上怀疑静脉血栓或碘流伪影的患者,以随访CT或彩色编码超声确认,比较门静脉期常规CT、碘图及40 keV噪声优化单能外推对静脉血栓与碘流伪影的检出和鉴别效能;碘图和40 keV单能外推的诊断置信度和准确度均显著高于常规门静脉期CT。

要点

  • 碘图和40 keV单能外推的诊断置信度均高于常规门静脉期CT。
  • 碘图和40 keV单能外推的AUC和敏感度均高于常规门静脉期CT。
  • 静脉血栓的碘定量显著低于碘流伪影。

核心结论

  • 与常规门静脉期CT相比,碘图和40 keV噪声优化单能外推对静脉血栓与碘流伪影的检出和鉴别具有显著更高的诊断置信度和准确度。

研究设计与样本

  • 研究纳入99例在增强CT上怀疑静脉血栓或碘流伪影的患者,所有检查均使用第三代双源CT系统于门静脉期以双能模式采集,由两名放射科医师独立评估常规门静脉期CT、碘图和40 keV噪声优化单能外推,以随访CT或彩色编码超声确认作为参考标准。

诊断标准与关键数值

  • 碘图AUC=88%、敏感度=79.1%,40 keV单能外推AUC=86%、敏感度=73.1%,常规门静脉期CT AUC=75%、敏感度=61.2%,碘图和40 keV单能外推较常规门静脉期CT的AUC和敏感度均显著更高(p≤0.01)。

临床应用与阅片要点

  • 碘图和40 keV单能外推的诊断置信度均为3(2-3),高于常规门静脉期CT的2(1-3)(p≤0.03)。
  • 静脉血栓的碘定量为0.55 mg/ml(0.23-0.90),显著低于碘流伪影的1.81 mg/ml(1.60-2.12)(p<0.001)。
  • 静脉血栓的CNR在碘图为11.5(8.5-14.5)、40 keV单能外推为10.9(8.8-15.5),均显著高于常规门静脉期CT的8.2(5.8-11.4)(p<0.001)。
  • 40 keV单能外推测得的血栓体积显著高于碘图和常规门静脉期CT(p<0.001)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To investigate the accuracy of dual-energy (DE) CT-based iodine maps (IM) and noise-optimised monoenergetic extrapolations (MEI+) at 40 keV for the detection and differentiation of venous thrombosis (VT) from iodine flux artefacts (IFA) in comparison to portal-venous phase CT (CTPV).

METHODS: Ninety-nine patients were enrolled in this study. In all patients, VT or IFA was suspected on contrast-enhanced CT and confirmed by follow-up CT or colour-coded ultrasound. All examinations were performed on a third-generation dual-source CT system in DE mode during portal-venous phase. CTPV, IM and 40-keV MEI+ were reconstructed and independently evaluated by two radiologists for the presence/absence of VT and/or IFA. Diagnostic confidence was rated on a three-point scale (3 = high confidence). Quantitative parameters were obtained by calculating contrast-to-noise ratios (CNRs), iodine content and thrombus volume. Diagnostic accuracy was assessed by calculating receiver operating characteristics (ROC) of CNR.

RESULTS: Diagnostic confidence was significantly higher for IM and MEI+ [both 3 (2-3)] compared to CTPV [2 (1-3); p ≤ 0.03]. ROC analysis revealed significantly higher AUC values and increased sensitivity for IM and MEI+ (AUC = 88%/sensitivity = 79.1% and 86%/73.1%) than for CTPV (75%/61.2%; p ≤ 0.01). Thrombus volume was significantly higher in MEI+ than in IM and CTPV (p < 0.001). CNR of thrombosis was significantly higher in IM [11.5 (8.5-14.5), p < 0.001) and MEI+ [10.9 (8.8-15.5), p < 0.001] than in CTPV [8.2 (5.8-11.4)]. Iodine quantification revealed significantly lower results in VT than in IFA [0.55 mg/ml (0.23-0.90) and 1.81 (1.60-2.12) mg/ml; p < 0.001].

CONCLUSIONS: IM and MEI+ 40 keV showed significantly higher diagnostic confidence and accuracy for the detection and differentiation of VT from IFA in comparison to CTPV.

KEY POINTS: • Iodine maps and noise-optimised monoenergetic extrapolations at 40 keV increase diagnostic confidence and accuracy for the detection and differentiation of venous thrombosis from iodine flux artefacts. • Dual-energy post-processing can significantly increase contrast-to-noise ratio and the sensitivity for the diagnosis of venous thrombosis • Iodine load in venous thrombosis is significantly lower than in iodine flux artefacts.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Weiss J, Schabel C, Othman AE, et al. Impact of dual-energy CT post-processing to differentiate venous thrombosis from iodine flux artefacts. Eur Radiol. 2018. PMID: 29869173. doi:10.1007/s00330-018-5534-8

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。