颈动脉支架置入术后新生内膜形成:体模与临床评估基于模型的迭代重建(MBIR)
研究在颈动脉支架体模和43例支架患者中评估基于模型迭代重建(FIRST)对新生内膜形成的检测价值,体模中FIRST测量误差小于FBP和AIDR 3D;临床以颈动脉超声为参考标准,AIDR 3D联合FIRST的敏感度84%、特异度78%、AUC 0.82,均优于单用AIDR 3D(敏感度58%、特异度88%、AUC 0.72),平均AUC差异有统计学意义(p < 0.01)。
要点
- 基于模型迭代重建(FIRST)可提高颈动脉支架术后新生内膜形成的检出敏感度(84% vs 58%)。
- FIRST联合AIDR 3D的平均AUC为0.82,高于单用AIDR 3D的0.72(p < 0.01)。
- 体模中FIRST对0.40–1.00 mm新生内膜的测量误差小于FBP和AIDR 3D。
核心结论
- 基于模型的迭代重建算法有助于提高颈动脉支架置入术后新生内膜形成的诊断性能。
研究设计与样本
- 体模研究在含颈动脉支架的颈部体模中放置0.40、0.60、0.80和1.00 mm模拟新生内膜,比较FBP、混合迭代重建(AIDR 3D)和基于模型迭代重建(FIRST)的测量误差;临床研究纳入43例颈动脉支架患者,320排CT颈部图像以AIDR 3D和FIRST重建,5名盲法观察者视觉分级,以颈动脉超声为参考标准,采用Jack-knife型受试者操作特征分析软件分析。
关键影像表现/征象
- 体模中FIRST图像上新生内膜测量值与真实直径的差异小于FBP或AIDR 3D图像。
- 临床研究以颈动脉超声为参考标准,比较AIDR 3D与AIDR 3D联合FIRST图像对新生内膜形成的视觉分级诊断性能。
诊断标准与关键数值
- AIDR 3D检测新生内膜形成的敏感度58%、特异度88%、阳性预测值83%、阴性预测值67%、准确率73%。
- AIDR 3D联合FIRST图像的敏感度84%、特异度78%、阳性预测值80%、阴性预测值82%、准确率81%。
- AIDR 3D联合FIRST的平均AUC为0.82,高于AIDR 3D的0.72(p < 0.01)。
临床应用与阅片要点
- 作者结论认为基于模型迭代重建算法有助于提高颈动脉支架术后新生内膜形成的诊断性能。
- 要点指出基于模型迭代重建可更准确地显示新生内膜形成。
- 要点指出基于模型迭代重建适合颈动脉支架置入术后的随访。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: The objective of this study was to investigate the usefulness of model-based iterative reconstruction (IR) for detecting neointimal formations after carotid artery stenting.
METHODS: In a cervical phantom harbouring carotid artery stents, we placed simulated neointimal formations measuring 0.40, 0.60, 0.80 and 1.00 mm along the stent wall. The thickness of in-stent neointimal formations was measured on images reconstructed with filtered-back projection (FBP), hybrid IR (AIDR 3D), and model-based IR (FIRST). The clinical study included 43 patients with carotid stents. Cervical computed tomography (CT) images obtained on a 320-slice scanner were reconstructed with AIDR 3D and FIRST. Five blinded observers visually graded the likelihood of neointimal formations on AIDR 3D and AIDR 3D plus FIRST images. Carotid ultrasound images were the reference standard. We analysed results of visual grading by using a Jack-knife type receiver observer characteristics analysis software.
RESULTS: In the phantom study, the difference between the measured and the true diameter of the neointimal formations was smaller on FIRST than FBP or AIDR 3D images. In the clinical study, the sensitivity, specificity, positive predictive value, negative predictive value and accuracy of AIDR 3D were 58%, 88%, 83%, 67% and 73%, respectively. For AIDR 3D plus FIRST images they were 84%, 78%, 80%, 82% and 81%, respectively. The mean area under the curve was significantly higher on AIDR 3D plus FIRST than AIDR 3D images (0.82 vs 0.72; p < 0.01).
CONCLUSIONS: The model-based IR algorithm helped to improve diagnostic performance for the detection of neointimal formations after carotid artery stenting.
KEY POINTS: • Neointimal formations can be visualised more accurately with model-based IR. • Model-based IR improves the detection of neointimal formations after carotid artery stenting. • Model-based IR is suitable for follow up after carotid artery stenting.