简化MRI方案检测老年人X线隐匿性髋部及骨盆骨折的诊断准确性
本研究纳入111例65岁以上急诊患者,在X线阴性后行MRI检查,比较仅含冠状位T1和STIR序列的简化方案与完整六序列MRI对髋部及骨盆骨折的诊断准确性。结果显示,简化方案对股骨近端骨折的合并敏感度和特异度分别为100%和97%,对骨盆骨折的敏感度和特异度分别为92%和98%,骨折分类的kappa系数分别为0.90和0.88,提示与完整MRI高度一致。
要点
- 简化MRI方案(仅冠状位T1和STIR)对股骨近端骨折的合并敏感度100%、特异度97%。
- 对骨盆骨折的敏感度92%、特异度98%,骨折分类与完整MRI高度一致(kappa 0.90和0.88)。
- 在X线阴性的老年髋部骨折疑似患者中,简化方案可维持高诊断准确性。
核心结论
- 仅包含冠状位T1和STIR序列的简化MRI方案对髋部和骨盆骨折检测及骨折分类保持高敏感度和特异度。
研究设计与样本
- 连续纳入111例65岁及以上急诊患者,X线阴性后行MRI评估临床疑似髋部骨折,从完整六序列MRI中分离出大视野冠状位T1和STIR序列,由两名骨肌放射学专科培训医师盲法独立阅片,计算95%置信区间内的检验准确性并与完整MRI比较。
诊断标准与关键数值
- 对股骨近端骨折,简化方案两名读者合并敏感度100%、特异度97%;对骨盆骨折,敏感度92%、特异度98%;骨折分类kappa系数读者1为0.90、读者2为0.88。
临床应用与阅片要点
- 作者认为,仅包含冠状位T1和STIR序列的简化MRI方案对髋部和骨盆骨折检测及骨折分类保持高敏感度和特异度,可用于临床疑似髋部骨折且X线阴性的老年患者。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To determine the diagnostic accuracy of an abbreviated, two-sequence MRI protocol using limited pulse sequences for the detection of radiographically occult hip and pelvis fractures in the elderly compared to the complete MRI examination.
MATERIALS AND METHODS: One hundred and eleven consecutive emergency department patients age 65 or older who had undergone MRI to evaluate for clinically suspected hip fracture after negative radiographs were included in the study. The large field-of-view coronal T1 and STIR sequences were isolated from the complete six-sequence MRI protocol and reviewed independently in a blinded fashion by two musculoskeletal fellowship-trained radiologists who recorded presence or absence of fractures of the proximal femora or pelvis, fracture type, and presence or absence of soft tissue injury. Test accuracy was calculated with 95% confidence intervals and accuracy of fracture classification for the abbreviated protocol was compared to that made on the basis of the full exam.
RESULTS: For proximal femoral fractures, the abbreviated protocol had a pooled sensitivity and specificity for the two readers of 100 and 97%, respectively. For pelvic fractures, sensitivity was 92% and specificity was 98%. The kappa coefficient for fracture classification was 0.90 for reader 1 and 0.88 for reader 2, indicating excellent agreement for both readers in fracture classification compared to the classification made based on the complete MRI protocol.
CONCLUSIONS: An abbreviated MRI protocol that includes only coronal T1 and STIR sequences maintains high sensitivity and specificity for hip and pelvis fracture detection and fracture classification.
引用
- Ross AB, Chan BY, Yi PH, et al. Diagnostic accuracy of an abbreviated MRI protocol for detecting radiographically occult hip and pelvis fractures in the elderly. Skeletal Radiol. 2018. PMID: 29915937. doi:10.1007/s00256-018-3004-7