超声与定量剪切波弹性成像鉴别痛风急性期与间歇期
前瞻性纳入57例痛风患者,分为急性期与间歇期组,对第一跖趾关节行超声和剪切波弹性成像检查。彩色多普勒血流信号分级急性期高于间歇期,而滑膜最大和平均弹性模量间歇期高于急性期;剪切波弹性成像诊断效能优于常规超声。
要点
- 彩色多普勒血流信号分级急性期高于间歇期(p=0.001),B型超声特征两组间无差异(均p>0.05)。
- 剪切波弹性成像显示滑膜最大和平均弹性模量间歇期显著高于急性期(均p<0.001)。
- 剪切波弹性成像联合彩色多普勒超声较单用彩色多普勒超声显著提高曲线下面积、敏感度和准确率(均p<0.001)。
核心结论
- 与常规超声相比,剪切波弹性成像提高了鉴别痛风急性期与间歇期的诊断效能。
研究设计与样本
- 前瞻性研究,纳入57例痛风患者并分为急性期与间歇期组,对第一跖趾关节按同一方案行超声和剪切波弹性成像检查,由两名放射科医师独立评估超声特征。
关键影像表现/征象
- 彩色多普勒血流信号分级急性期高于间歇期(p=0.001)。
- B型超声特征两组间均无差异(均p>0.05)。
- 剪切波弹性成像显示滑膜最大弹性模量(Emax)和平均弹性模量(Emean)间歇期显著高于急性期(均p<0.001)。
诊断标准与关键数值
- B型超声鉴别急性期与间歇期的曲线下面积为0.494-0.553。
- 彩色多普勒超声的曲线下面积为0.735。
- Emax的曲线下面积为0.887,Emean的曲线下面积为0.882。
- 彩色多普勒超声联合剪切波弹性成像较单用彩色多普勒超声显著提高曲线下面积、敏感度和准确率(均p<0.001),但联合方案与单用剪切波弹性成像相比未显示更强诊断效能。
临床应用与阅片要点
- 阅片时注意彩色多普勒血流信号分级在急性期更高,而滑膜硬度在间歇期更高,两者结合有助于分期。
- B型超声特征在急性期与间歇期之间无差异,不宜单独用于区分痛风分期。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To evaluate the value of ultrasound (US) in differentiating the acute phase of gout from the intercritical phase, particularly using shear wave elastography (SWE).
METHODS: 57 gout patients were prospectively enrolled and divided into acute phase and intercritical phase groups. The patients underwent US and SWE examinations for the first metatarsophalangeal joints with the same protocol. Maximum synovial thickness was measured. US features were reviewed by two radiologists independently. The maximum (Emax) and mean (Emean) elastic moduli of synovium were calculated. Diagnostic performances of US, SWE and combined US and SWE were evaluated.
RESULTS: US findings demonstrated that the colour Doppler flow signal grade in the acute phase was higher than that in the intercritical phase (p = 0.001), whereas no differences were found for B-mode US features between the two groups (all p > 0.05). For SWE, Emax and Emean were significantly higher in the intercritical phase than in the acute phase (both p < 0.001). The areas under the receiver operating characteristic curve (AUROCs) were 0.494-0.553 for B-mode US, 0.735 for colour Doppler US (CDUS), 0.887 for Emax and 0.882 for Emean. The combination of CDUS and SWE increased the AUROC, sensitivity and accuracy significantly in comparison with CDUS alone (all p < 0.001). However, the combined set did not show stronger diagnostic performance in comparison with SWE alone.
CONCLUSION: SWE increases the diagnostic performance in differentiating the acute phase of gout from the intercritical phase in comparison with conventional US.
KEY POINTS: • Colour Doppler flow signal grade is higher in acute phase of gout than in intercritical phase. • SWE demonstrates that synovium stiffness is higher in intercritical phase of gout than in acute phase. • SWE increases diagnostic performance in differentiating acute phase of gout from intercritical phase in comparison with conventional US.
引用
- Wang Q, Guo LH, Li XL, et al. Differentiating the acute phase of gout from the intercritical phase with ultrasound and quantitative shear wave elastography. Eur Radiol. 2018. PMID: 29869177. doi:10.1007/s00330-018-5529-5
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。