文献速递骨肌介入CT

腰椎根周浸润:迭代重建软件是否是建立超低剂量方案的必需?定量与定性研究

Periradicular infiltration of the lumbar spine: is iterative reconstruction software necessary to establish ultra-low-dose protocols? A quantitative and qualitative approach.
PubMed 文献 · Radiol Med · 2018-06-19

本研究纳入100例接受CT引导下腰椎根周浸润治疗的患者,采用超低剂量方案并分别用AIDR 3D迭代重建和滤波反投影重建图像,由4名经验丰富的评估者评价解剖与器械特征显示清晰度,并测量图像噪声。结果显示两种重建算法在81.3%的病例中评分相同,AIDR 3D图像噪声显著更低,但迭代重建软件并非获得满足治疗引导所需图像质量的必需条件。

要点

  • 超低剂量CT引导腰椎根周浸润时,AIDR 3D与FBP重建对解剖和器械特征的评分在81.3%病例中一致。
  • AIDR 3D重建图像噪声显著低于FBP(平均SD 60.07 vs 99.54,p<0.05)。
  • 迭代重建软件并非超低剂量CT引导腰椎根周浸润获得合格图像质量的必需条件。

核心结论

  • 尽管迭代重建软件显著降低图像噪声,但在超低剂量CT引导腰椎根周浸润治疗方案中,迭代重建软件并非获得满足安全治疗所需图像质量的必需条件。

研究设计与样本

  • 研究纳入100例接受CT引导下腰椎根周浸润治疗的患者,使用超低剂量方案并分别采用AIDR 3D迭代重建和滤波反投影(FBP)重建图像;由4名经验丰富的评估者评价两种重建图像对确保安全治疗重要的解剖和器械特征的显示清晰度,并测量图像噪声作为图像质量的定量指标。

诊断标准与关键数值

  • 评估者间一致性良好:AIDR 3D重建Kendall's W=0.83,FBP重建Kendall's W=0.78;两种重建算法在所有特征上评分相同的病例占81.3%;图像噪声以平均SD表示,AIDR 3D重建为60.07,FBP重建为99.54,AIDR 3D显著更低(p<0.05)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: Computed tomography (CT)-guided periradicular infiltration therapy has emerged as an effective treatment option for patients with low back pain. Concern about radiation exposure requires approaches allowing significant dose reduction. The purpose of this study is to evaluate the need for iterative reconstruction software in CT-guided periradicular infiltration therapy with an ultra-low-dose protocol.

MATERIALS AND METHODS: One hundred patients underwent CT-guided periradicular infiltration therapy of the lumbar spine using an ultra-low-dose protocol with adaptive iterative dose reduction 3D (AIDR 3D) for image reconstruction. In addition, images were reconstructed with filtered back-projection (FBP). Four experienced raters evaluated both reconstruction types for conspicuity of anatomical and instrumental features important for ensuring safe patient treatment. Image noise was measured as a quantitative marker of image quality.

RESULTS: Interrater agreement was good for both AIDR 3D (Kendall's W = 0.83) and FBP (0.78) reconstructions. Readers assigned the same scores for all features and both reconstruction algorithms in 81.3% of cases. Image noise was significantly lower (average SD of 60.07 vs. 99.54, p < 0.05) for AIDR 3D-reconstructed images.

CONCLUSION: Although it significantly lowers image noise, iterative reconstruction software is not mandatory to achieve adequate image quality with an ultra-low-dose CT protocol for guiding periradicular infiltration therapy of the lumbar spine.