文献速递乳腺乳腺X线

双盲双重阅片乳腺X线筛查中一致性召回与不一致性召回后筛查检出癌的特征

Characteristics of screen-detected cancers following concordant or discordant recalls at blinded double reading in biennial digital screening mammography.
PubMed 文献 · Eur Radiol · 2018-06-25

该研究纳入2013年7月至2015年1月间连续99,013例筛查乳腺X线摄影,均行双盲双重阅片,不一致阅片常规召回而不经共识或仲裁。共2,543例一致性召回(71.4%)和997例不一致性召回(28.0%)。一致性召回阳性预测值显著更高(23.5% vs 10.0%,p<0.001);不一致性召回组BI-RADS 0比例更高(75.7% vs 56.3%),不对称和结构扭曲更常见(21.8% vs 13.2%和9.3% vs 6.5%),不一致性召回组肿瘤分级更有利(I级54.7% vs 39.9%,p=0.022)。

要点

  • 不一致性召回组BI-RADS 0比例75.7%,高于一致性召回组56.3%(p<0.001)
  • 不一致性召回组不对称21.8% vs 13.2%、结构扭曲9.3% vs 6.5%,均高于一致性召回组(p<0.001)
  • 不一致性召回组I级肿瘤54.7% vs 一致性召回组39.9%(p=0.022)

核心结论

  • 不一致性阅片检出的筛查癌肿瘤分级比一致性召回后诊断的癌更有利,该组不对称和结构扭曲比例更高,可能为改进筛查方案提供靶点。

研究设计与样本

  • 研究纳入2013年7月至2015年1月间连续99,013例筛查乳腺X线摄影,均行双盲双重阅片,不一致阅片常规召回而不经共识或仲裁,随访2年收集召回女性相关数据,比较一致性召回与不一致性召回的乳腺X线特征、筛查结局和肿瘤特征。

关键影像表现/征象

  • 不一致性召回组BI-RADS 0比例75.7%,高于一致性召回组56.3%(p<0.001)
  • 不一致性召回组不对称21.8% vs 一致性召回组13.2%(p<0.001)
  • 不一致性召回组结构扭曲9.3% vs 一致性召回组6.5%(p<0.001)
  • DCIS和浸润性癌的分布两组无差异,除肿瘤分级外两组肿瘤特征相当

诊断标准与关键数值

  • 一致性召回阳性预测值23.5%,不一致性召回阳性预测值10.0%(p<0.001)
  • 不一致性召回组I级肿瘤54.7% vs 一致性召回组39.9%(p=0.022)

临床应用与阅片要点

  • 作者认为额外培训筛查放射科医生和实施数字乳腺断层摄影可能作为改进筛查方案的策略。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To analyse which mammographic and tumour characteristics led to concordant versus discordant recalls at blinded double reading to further optimise our breast cancer screening programme.

METHODS: We included a consecutive series of 99,013 screening mammograms obtained between July 2013 and January 2015. All mammograms were double read in a blinded fashion. Discordant readings were routinely recalled without consensus or arbitration. During the 2-year follow-up, relevant data of the recalled women were collected. We compared mammographic characteristics, screening outcome and tumour characteristics between concordant and discordant recalls.

RESULTS: There were 2,543 concordant recalls (71.4%) and 997 discordant recalls (28.0%). The positive predictive value of a concordant recall was significantly higher (23.5% vs. 10.0%, p < 0.001). The proportion of BI-RADS 0 was significantly higher in the discordant recall group (75.7% vs. 56.3%, p < 0.001). Discordant recalls were more often an asymmetry or architectural distortion (21.8% vs. 13.2% and 9.3% vs. 6.5%, respectively, p < 0.001). There were no differences in the distribution of DCIS and invasive cancers and tumour characteristics were comparable for the two groups, except for a more favourable tumour grade in the discordant recall group (54.7% vs. 39.9% grade I tumours, p = 0.022).

CONCLUSIONS: Screen-detected cancers detected by a discordant reading show a more favourable tumour grade than cancers diagnosed after a concordant recall. The higher proportion of asymmetries and architectural distortions in this group provide a possible target for improving screening programmes by additional training of screening radiologists and the implementation of digital breast tomosynthesis.

KEY POINTS: • With blinded double reading of screening mammograms, screen-detected cancers detected by a discordant reading show a more favourable tumour grade than cancers diagnosed after a concordant recall. • The proportions of asymmetries and architectural distortions are higher in case of a discordant reading. • Possible improvement strategies could target additional training of screening radiologists and the implementation of digital breast tomosynthesis in breast cancer screening programmes.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Coolen AMP, Lameijer JRC, Voogd AC, et al. Characteristics of screen-detected cancers following concordant or discordant recalls at blinded double reading in biennial digital screening mammography. Eur Radiol. 2018. PMID: 29943181. doi:10.1007/s00330-018-5586-9

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。