新型勾画工具「MIRADA」在区域淋巴结层面的应用:早期乳腺癌患者的逐步开发与初步结果
本研究描述了使用Mirada软件实施和优化勾画的实践流程,并评估其对早期乳腺癌患者日常实践中淋巴结和危及器官的自动分割效果。40例治疗体位CT扫描按欧洲放射肿瘤学会指南重新勾画并创建自动勾画图谱,30例接受乳腺/胸壁及淋巴结区域照射的患者用于评估;软件勾画(含修正)全部感兴趣区总时间30分钟,较手动勾画目标体积和危及器官节省约40%时间,5个主要危及器官平均一致性指数≥0.8,但淋巴结自动勾画平均一致性指数仅0.43±0.1(范围0.23-0.52),作者认为淋巴结区域勾画有待改进,系统常规使用需更多病例和进一步评估。
要点
- Mirada自动勾画5个主要危及器官平均一致性指数≥0.8,可节省勾画时间。
- 淋巴结自动勾画平均一致性指数仅0.43±0.1(范围0.23-0.52),满意度较低。
- 软件勾画全部感兴趣区(含修正)总时间30分钟,较手动勾画节省约40%时间。
核心结论
- 对于乳腺癌患者,所研究软件可节省勾画时间且危及器官轮廓可接受,但淋巴结区域勾画有待改进,系统常规使用需更多病例和进一步评估。
研究设计与样本
- 研究选取40例治疗体位CT扫描按欧洲放射肿瘤学会指南重新勾画并创建自动勾画图谱,另招募30例接受乳腺/胸壁及淋巴结区域照射的患者,以放射肿瘤医师手动勾画为参考,用一致性指数评估Mirada自动勾画与手动勾画的一致性。
诊断标准与关键数值
- 以放射肿瘤医师手动勾画为参考,采用一致性指数评估自动与手动勾画的一致性;5个主要危及器官平均一致性指数≥0.8,淋巴结自动勾画平均一致性指数0.43±0.1(范围0.23-0.52)。
临床应用与阅片要点
- 作者认为该软件可节省勾画时间且危及器官轮廓可接受,但淋巴结区域勾画有待改进,系统常规使用需更多病例和进一步评估。
局限性
- 淋巴结区域勾画有待改进。
- 系统常规使用需更多病例和进一步评估。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE:: To describe the practical procedure of implementation and optimization of delineation using "Mirada" software, as well as evaluation of the automatic segmentation for the daily practice of lymph nodes (LN) and organs at risk (OARs) in early stage breast cancer patients.
METHODS:: 40 patients' CT scans in treatment position were selected and recontoured according to the European Society of Therapeutic Radiation Oncology guidelines. The atlas of data set was then created for automatic delineation. 30 patients with breast/chest wall and lymph nodes regions irradiated were recruited for evaluation. With the same treatment position, the CT scan images were acquired and then contoured by the MIRADA system automatically as well as by the radiation oncologist manually (as the reference). The conformity index (CI) was used to evaluate the concordance between both of them.
RESULTS:: The mean time for manual contour was 24.1 ± 5.1 and 26.4 ± 2.8 min for the LN and the OARs respectively. All the volumes of interest were contoured using the software (including corrections) in 30 min, which reduced the time of delineation of target volumes and OAR by about 40%. Of the 30 cases evaluated, the mean CI of 5 principal OARs showed ≥0.8. While the automatic contour of LN was less satisfactory with mean CI of 0.43 ± 0.1 (0.23-0.52).
CONCLUSION:: For the breast cancer patients, the studied software permitted to save time for delineation with acceptable OAR contours. The improvement of LN regions contour is needed. More cases and further evaluation are needed for the system to realize its routine use.
ADVANCES IN KNOWLEDGE:: It's the first description and evaluation of the automatic delineation and segmentation system for the breast cancer.
引用
- Xu H, Arsene Henry A, Robillard M, et al. The use of new delineation tool "MIRADA" at the level of regional lymph nodes, step-by-step development and first results for early-stage breast cancer patients. Br J Radiol. 2018. PMID: 29947264. doi:10.1259/bjr.20180095
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。