筛查环境中乳腺X线摄影密度的自动体积分析:致密乳腺女性结局更差
这项回顾性研究纳入2007至2015年挪威乳腺癌筛查项目中107 949名50-69岁女性(平均年龄58.7岁±5.6)的307 015次筛查检查,用自动软件按体积乳腺密度(VBD)将乳腺分为非致密(VBD<7.5%)或致密(VBD≥7.5%),比较两组筛查结局。致密乳腺占28%(87 021/307 015),其召回率、活检率、筛查检出癌率、间期癌率均更高,敏感度更低,筛查检出癌的平均肿瘤直径更大、淋巴结阳性比例更高。
要点
- 自动软件分类致密乳腺(VBD≥7.5%)占筛查检查的28%(87 021/307 015)。
- 致密乳腺召回率3.6% vs 非致密2.7%,活检率1.4% vs 1.1%,均P<.001。
- 致密乳腺敏感度71%(449/634)低于非致密82%(884/1083),P<.001。
核心结论
- 用自动软件分类的致密乳腺女性筛查检查,相比非致密乳腺女性,召回率更高、敏感度更低、肿瘤直径更大、淋巴结阳性病变更多。
研究设计与样本
- 回顾性研究,纳入2007至2015年挪威乳腺癌筛查项目107 949名50-69岁女性(平均年龄58.7岁±5.6)的307 015次筛查检查,自动软件按VBD<7.5%为非致密、VBD≥7.5%为致密分类,分析筛查结局并按密度分层。
诊断标准与关键数值
- VBD<7.5%为非致密,VBD≥7.5%为致密;非致密vs致密:召回率2.7%(5882/219 994)vs 3.6%(3101/87 021),活检率1.1%(2359/219 994)vs 1.4%(1209/87 021),筛查检出癌率5.5(1210/219 994)vs 6.7(581/87 021)/1000次检查,间期癌率1.2(199/165 324)vs 2.8(185/66 674)/1000次检查,均P<.001。
临床应用与阅片要点
- 自动软件VBD分类可用于筛查报告中的乳腺密度分层,致密乳腺女性召回率更高、敏感度更低,筛查检出癌更大且淋巴结阳性更多。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Purpose To describe screening outcomes from BreastScreen Norway stratified by volumetric breast density (VBD). Materials and Methods This retrospective study included data from 107 949 women aged 50-69 years (mean age ± standard deviation, 58.7 years ± 5.6) who underwent 307 015 screening examinations from 2007 to 2015. Automated software classified mammographic density as nondense (VBD <7.5%) or dense (VBD ≥7.5%). Rates and distributions of screening outcomes (recall, biopsy, screen-detected and interval breast cancer, positive predictive values of recall and of needle biopsy, sensitivity, specificity, and histopathologic tumor characteristics) were analyzed and stratified by density. Tests of proportions, including propensity score and t tests, were used. Results In 28% (87 021 of 307 015) of the screening examinations, the breasts were classified as dense. Recall rates for women with nondense versus dense breasts were 2.7% (5882 of 219 994) and 3.6% (3101 of 87 021); biopsy rates were 1.1% (2359 of 219 994) and 1.4% (1209 of 87 021); rates of screen-detected cancer were 5.5 (1210 of 219 994) and 6.7 (581 of 87 021) per 1000 examinations; and rates of interval breast cancer were 1.2 (199 of 165 324) and 2.8 (185 of 66 674) per 1000 examinations, respectively (P < .001 for all). Sensitivity was 82% (884 of 1083) for nondense breasts and 71% (449 of 634) for dense breasts, whereas specificity was 98% (160 973 of 164 440) and 97% (64 250 of 66 225), respectively (P < .001 for both). For screen-detected cancers, mean tumor diameter was 15.1 mm and 16.6 mm (P = .01), and lymph node-positive disease was found in 18% (170 of 936) and 24% (98 of 417) (P = .02) of women with nondense and dense breasts, respectively. Conclusion Screening examinations of women with dense breasts classified by using automated software resulted in higher recall rate, lower sensitivity, larger tumor diameter, and more lymph node-positive disease compared with women with nondense breasts.
引用
- Moshina N, Sebuødegård S, Lee CI, et al. Automated Volumetric Analysis of Mammographic Density in a Screening Setting: Worse Outcomes for Women with Dense Breasts. Radiology. 2018. PMID: 29944088. doi:10.1148/radiol.2018172972
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。