挪威乳腺癌筛查项目中女性连续多次检查的乳腺压迫参数变化
该研究分析了挪威乳腺癌筛查项目中25,143名50-69岁女性连续四次全视野数字乳腺X线筛查的压迫参数,发现压迫力、压迫压强和压迫后乳腺厚度从第一次到第四次检查均显著增加,头尾位相对增加18.3%、14.4%和8.4%,内外斜位相对增加12.3%、9.9%和6.9%(均p<0.001)。作者认为需进一步研究这种变化对图像质量和女性不适感的影响。
要点
- 连续筛查中压迫力、压迫压强和压迫后乳腺厚度呈逐渐增加趋势。
- 头尾位压迫力相对增加18.3%,内外斜位相对增加12.3%(均p<0.001)。
- 压迫参数的变化可能影响图像质量和受检者的不适与疼痛体验。
核心结论
- 在连续四次筛查检查中,乳腺压迫力、压迫压强和压迫后乳腺厚度均呈增加趋势,需进一步研究这种变化对图像质量和女性不适与疼痛体验的影响。
研究设计与样本
- 研究基于挪威乳腺癌筛查项目中两个乳腺中心2007年1月至2016年3月期间参加连续四次筛查的25,143名50-69岁女性的全视野数字乳腺X线筛查数据。
局限性
- 原文结论指出需进一步研究这种变化对图像质量和女性不适与疼痛体验的影响。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE:: Breast compression is used in mammography to improve image quality and reduce radiation dose. However, optimal values for compression force are not known, and studies have found large variation in use of compression forces between breast centres and radiographers. We investigated breast compression parameters, including compression force, compression pressure and compressed breast thickness across four consecutive full field digital mammography screening examinations for 25,143 subsequently screened females aged 50-69 years.
METHODS:: Information from females attending four consecutive screening examinations at two breast centres in BreastScreen Norway during January 2007 - March 2016 was available. We compared the changes in compression force, compression pressure and compressed breast thickness from the first to fourth consecutive screening examination, stratified by craniocaudal (CC) and mediolateral oblique (MLO) view.
RESULTS:: Compression force, compression pressure and compressed breast thickness increased relatively by 18.3, 14.4 and 8.4% respectively, from first to fourth consecutive screening examination in CC view (p<0.001 for all). For MLO view, the values increased relatively by 12.3% for compression force, 9.9% for compression pressure and 6.9% for compressed breast thickness from first to fourth consecutive screening examination (p<0.001 for all).
CONCLUSION:: We observed increasing values of breast compression parameters across consecutive screening examinations. Further research should investigate the effect of this variation on image quality and females' experiences of discomfort and pain.
ADVANCES IN KNOWLEDGE:: Breast compression force, compression pressure and compressed breast thickness increased across consecutive screening examinations, which might be of influence for the females' experiences of discomfort and pain during the examination and for image quality.