早孕期联合筛查子痫前期中子宫动脉多普勒测量质量评估

Quality assessment of uterine artery Doppler measurement in first-trimester combined screening for pre-eclampsia.
PubMed 文献 · Ultrasound Obstet Gynecol · 2019-01-11

在澳大利亚悉尼一家大型诊所,对2014年5月至2017年2月连续早孕期筛查的21010例单胎孕妇按FMF算法行子痫前期筛查,评估46名超声医师平均子宫动脉搏动指数测量质量。42名操作超过50例者中41名测量在可接受范围,测量值系统性偏低或偏高者筛查阳性率分别降低或升高。

要点

  • 平均UtA-PI MoM在0.95–1.05为理想、0.90–1.10为可接受,多数训练有素操作者达标。
  • 测量平均值低于0.95者筛查阳性率7.2%,高于1.05者13.2%,均在0.95–1.05者11.2%(P<0.001)。
  • 系统性误差影响筛查阳性率,应建立质量控制并可能需要重新培训人员。

核心结论

  • 训练有素的操作者按既定方案测量UtA多普勒质量良好,但测量存在系统性误差时会影响筛查阳性率,因此应建立质量控制流程并可能需要重新培训人员。

研究设计与样本

  • 在澳大利亚悉尼一家大型诊所,2014年5月至2017年2月连续纳入单胎妊娠早孕期筛查胎儿染色体异常并按FMF算法行子痫前期联合筛查的孕妇,共21010例,由46名超声医师测量平均UtA-PI。

诊断标准与关键数值

  • 以平均UtA-PI MoM的对数分布评估测量质量,0.95–1.05为理想、0.90–1.10为可接受;总体中位UtA-PI MoM为1.042(IQR 0.85–1.26)。

临床应用与阅片要点

  • 46名超声医师中42名(91.3%)检查超过50例,其中41名(97.6%)测量在可接受范围;测量均值低于0.95者筛查阳性率7.2%、高于1.05者13.2%,均在0.95–1.05者11.2%(P<0.001)。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To assess the quality of mean uterine artery (UtA) pulsatility index (PI) measurement in a first-trimester pre-eclampsia screening program.

METHODS: Consecutive women with a singleton pregnancy attending first-trimester screening for fetal chromosomal abnormalities also had combined screening for pre-eclampsia based on the Fetal Medicine Foundation (FMF) algorithm, at a large practice in Sydney, Australia, from May 2014 to February 2017. Distributions of mean UtA-PI multiples of the median (MoM) on a logarithmic scale were plotted in relation to the normal median with 95% CI for each operator and for each month. Central tendency and dispersion and cumulative sum charts were produced. Mean UtA-PI MoM values between 0.95 and 1.05 were considered ideal and those between 0.90 and 1.10 were considered acceptable. The screen-positive rates for preterm pre-eclampsia in different groups of sonographers according to their mean log10 UtA-PI MoM were calculated and compared using the chi-square test.

RESULTS: A total of 21 010 women attended for first-trimester ultrasound and had screening for pre-eclampsia. The overall median UtA-PI MoM was 1.042 (interquartile range (IQR), 0.85-1.26). Of 46 sonographers, 42 (91.3%) performed more than 50 examinations and, of those, 41 (97.6%) measured UtA-PI within the acceptable range. Sonographers measuring UtA-PI MoM on average below 0.95 and those measuring it above 1.05 had, respectively, lower and higher screen-positive rates when compared with those with measurements within the 0.95-1.05 UtA-PI MoM interval (7.2% and 13.2% vs 11.2%, respectively, P < 0.001).

CONCLUSION: UtA Doppler is measured well among trained operators when following an established protocol. While slight variations are expected, systematic error in this measurement impacts on the screen-positive rate. Therefore, a quality control process should be in place and retraining of staff may be required. Copyright © 2018 ISUOG. Published by John Wiley & Sons Ltd.

来源:Ultrasound Obstet Gynecol,查看原文。版权归原作者所有。

引用

  1. Rolnik DL, da Silva Costa F, Sahota D, et al. Quality assessment of uterine artery Doppler measurement in first-trimester combined screening for pre-eclampsia. Ultrasound Obstet Gynecol. 2019. PMID: 29917286. doi:10.1002/uog.19116

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。