双能CT评估多囊肾:解读时间与诊断信心的多读者研究
回顾性纳入55例多囊肾患者的门静脉期双源双能CT,比较碘叠加图像与模拟肾脏肿块方案CT。碘叠加图像解读更快(平均55±26秒 vs 105±51秒,p<0.001),最高诊断信心比例更高(64% vs 17%,p<0.0001),记录病变的患者比例无显著差异(p=0.62)。
要点
- 碘叠加图像解读时间较肾脏肿块方案CT缩短(平均55±26秒 vs 105±51秒,p<0.001)。
- 碘叠加图像最高诊断信心评级比例64%,肾脏肿块方案CT为17%(p<0.0001)。
- 两种方法记录病变的患者比例无显著差异(p=0.62)。
核心结论
- 双能CT通过缩短解读时间、提高诊断信心来改善多囊肾病变评估,且不影响病变检出率。
研究设计与样本
- 回顾性多读者研究,纳入2013年9月至2016年2月间55例多囊肾(囊肿4个或以上)患者的门静脉期双源双能CT扫描,每例生成碘叠加图像与模拟肾脏肿块方案CT(虚拟平扫和混合图像)两组图像,由两名放射科医生独立回顾分析。
诊断标准与关键数值
- 评估对象为不确定良性病变(强化病变或Bosniak IIF类囊肿),诊断信心采用Likert 5级量表;碘叠加图像最高诊断信心评级占64%,肾脏肿块方案CT占17%(p<0.0001);记录病变的患者比例两种方法无显著差异(p=0.62)。
临床应用与阅片要点
- 原文结论为双能CT碘叠加图像可缩短多囊肾评估的解读时间并提高诊断信心,且病变检出率不受影响。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To compare dual-energy CT (DECT) iodine overlay images with renal mass protocol CT in the evaluation of polycystic kidneys with respect to reading time, diagnostic confidence, and detection of renal lesions that are not definitively benign.
METHODS: Following IRB approval, portal venous phase dual-source DECT scans performed between September 2013 and February 2016 from 55 patients (mean age 67 ± 15 years, 31 male, 24 female) with polycystic kidneys (4 or more cysts) were included. For each patient, two image sets were created: (1) DECT post-processed iodine overlay images and (2) simulated renal mass protocol CT images (virtual noncontrast and mixed images). Two radiologists independently retrospectively reviewed both sets at separate time points, evaluating for the presence of lesions that were not definitively benign (enhancing lesions or Bosniak IIF cysts), as well as reading times and Likert scale diagnostic confidence ratings (scaled 1-5) for the presence of non-benign lesions. Reading times were compared with a t test, diagnostic confidence with a McNemar test, and lesion number detection with Cohen's kappa test.
RESULTS: Iodine overlay images were read faster (mean 55 ± 26 s) than renal mass protocol (mean 105 ± 51 s) (p < 0.001). Readers assigned the highest diagnostic confidence rating in 64% using iodine overlay series, compared to 17% using renal mass protocol (p < 0.0001). The proportion of patients with recorded lesions was not significantly different between methods (p = 0.62).
CONCLUSIONS: DECT improves lesion assessment in polycystic kidneys by decreasing reading times and increasing diagnostic confidence, without affecting lesion detection rates.
引用
- Glomski SA, Wortman JR, Uyeda JW, et al. Dual energy CT for evaluation of polycystic kidneys: a multi reader study of interpretation time and diagnostic confidence. Abdom Radiol (NY). 2018. PMID: 29926138. doi:10.1007/s00261-018-1674-1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。