文献速递泌尿生殖技术与安全US

剪切波弹性成像评估慢性肾脏病患者肾实质硬度

Shear wave elastography in the evaluation of renal parenchymal stiffness in patients with chronic kidney disease.
PubMed 文献 · Br J Radiol · 2018-06-21

研究纳入106例慢性肾脏病患者与203例对照,用剪切波弹性成像测量肾实质杨氏模量并与估算肾小球滤过率等指标相关。杨氏模量与估算肾小球滤过率呈负相关(r=-0.576,p<0.0001),剪切波弹性成像诊断慢性肾脏病的曲线下面积(0.87)优于常规超声(0.35-0.37);杨氏模量≤4.31 kPa提示肾脏无病变(敏感度80.3%、特异度79.5%)。

要点

  • 剪切波弹性成像测得的杨氏模量与估算肾小球滤过率呈负相关(r=-0.576,p<0.0001)。
  • 剪切波弹性成像诊断慢性肾脏病的曲线下面积为0.87,优于常规超声的0.35-0.37。
  • 杨氏模量≤4.31 kPa提示肾脏无病变,敏感度80.3%、特异度79.5%。

核心结论

  • 剪切波弹性成像在检测慢性肾脏病方面优于肾长度和皮质厚度,杨氏模量≤4.31 kPa在判断肾脏有无病变时显示出良好准确度。

研究设计与样本

  • 研究纳入106例慢性肾脏病患者和203例对照受试者,采用常规超声测量肾长度和皮质厚度,采用剪切波弹性成像测量肾实质硬度,并以血清肌酐、尿素水平和估算肾小球滤过率为参照进行分析。

关键影像表现/征象

  • 慢性肾脏病患者剪切波弹性成像显示肾实质硬度高于非慢性肾脏病患者。

诊断标准与关键数值

  • 杨氏模量与估算肾小球滤过率呈负相关(r=-0.576,p<0.0001)。
  • 杨氏模量与年龄呈正相关(r=0.321,p<0.05),与血清肌酐呈正相关(r=0.375,p<0.0001),与尿素呈正相关(r=0.287,p<0.0001)。
  • 剪切波弹性成像诊断慢性肾脏病的曲线下面积为0.87,优于常规超声的0.35-0.37。
  • 杨氏模量≤4.31 kPa提示肾脏无病变,敏感度80.3%、特异度79.5%。

临床应用与阅片要点

  • 剪切波弹性成像测得的肾实质杨氏模量可作为一种无创指标,用于辅助判断肾脏是否存在慢性肾脏病相关异常。
  • 作者认为,确定正常与病变肾实质之间的截断值可能有助于慢性肾脏病的早期无创检测和管理。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To investigate the use of shear wave elastography (SWE)-derived estimates of Young's modulus (YM) as an indicator to detect abnormal renal tissue diagnosed by estimated glomerular filtration rate (eGFR).

METHODS: The study comprised 106 chronic kidney disease (CKD) patients and 203 control subjects. Conventional ultrasound was performed to measure the kidney length and cortical thickness. SWE imaging was performed to measure renal parenchymal stiffness. Diagnostic performance of SWE and conventional ultrasound were correlated with serum creatinine, urea levels and eGFR.

RESULTS: Pearson's correlation coefficient revealed a negative correlation between YM measurements and eGFR (r = -0.576, p < 0.0001). Positive correlations between YM measurements and age (r = 0.321, p < 0.05), serum creatinine (r = 0.375, p < 0.0001) and urea (r = 0.287, p < 0.0001) were also observed. The area under the receiver operating characteristic curve for SWE (0.87) was superior to conventional ultrasound alone (0.35-0.37). The cut-off value of less or equal to 4.31 kPa suggested a non-diseased kidney (80.3% sensitivity, 79.5% specificity).

CONCLUSION: SWE was superior to renal length and cortical thickness in detecting CKD. A value of 4.31 kPa or less showed good accuracy in determining whether a kidney was diseased or not. Advances in knowledge: On SWE, CKD patients show greater renal parenchymal stiffness than non-CKD patients. Determining a cut-off value between normal and diseased renal parenchyma may help in early non-invasive detection and management of CKD.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Leong SS, Wong JHD, Md Shah MN, et al. Shear wave elastography in the evaluation of renal parenchymal stiffness in patients with chronic kidney disease. Br J Radiol. 2018. PMID: 29869920. doi:10.1259/bjr.20180235

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。