改进散射校正算法重建的68Ga-PSMA-II与68Ga-RM2 PET图像的临床评估

Clinical Evaluation of 68Ga-PSMA-II and 68Ga-RM2 PET Images Reconstructed With an Improved Scatter Correction Algorithm.
PubMed 文献 · AJR Am J Roentgenol · 2018-06-06

研究通过改进基于模型的散射校正算法(针对PET/MRI扫描仪几何和非FDG示踪剂挑战),对53例临床68Ga-RM2和68Ga-PSMA-11全身图像进行重建,并与基线算法比较。三位盲法评估者用5点Likert量表评分显示,改进算法显著减少或完全消除了肾脏和膀胱区域的洗脱伪影,图像质量提高。结论提示改进散射校正算法可恢复诊断图像质量,可能避免使用利尿剂。

要点

  • 改进散射校正算法可显著减少或完全消除68Ga PET肾脏和膀胱区域的洗脱伪影。
  • 图像质量提高,伪影减少,适用于68Ga-RM2和68Ga-PSMA-11两种示踪剂。
  • 患者未接受呋塞米,提示改进算法后可能避免使用利尿剂。

核心结论

  • 改进散射校正算法重建可减轻洗脱伪影并恢复68Ga PET的诊断图像质量,提示可能避免使用利尿剂。

研究设计与样本

  • 对53例临床68Ga-RM2和68Ga-PSMA-11全身图像使用基线散射算法重建,并与改进单次散射估计采样和散射尾部缩放偏移的重建比较;三位盲法评估者独立用5点Likert量表评分;患者均未接受呋塞米。

诊断标准与关键数值

  • 图像质量采用5点Likert量表由三位盲法评估者独立评分;比较基线与最改进算法,68Ga-RM2和68Ga-PSMA-11在肾脏和膀胱区域的图像质量提高、伪影减少。

临床应用与阅片要点

  • 改进散射校正算法重建有助于减少68Ga PET肾脏和膀胱区域的洗脱伪影,提高图像质量。
  • 患者未接受呋塞米仍获得改善,提示改进算法后可能避免使用利尿剂。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: Gallium-68-labeled radiopharmaceuticals pose a challenge for scatter estimation because their targeted nature can produce high contrast in these regions of the kidneys and bladder. Even small errors in the scatter estimate can result in washout artifacts. Administration of diuretics can reduce these artifacts, but they may result in adverse events. Here, we investigated the ability of algorithmic modifications to mitigate washout artifacts and eliminate the need for diuretics or other interventions.

MATERIALS AND METHODS: The model-based scatter algorithm was modified to account for PET/MRI scanner geometry and challenges of non-FDG tracers. Fifty-three clinical 68Ga-RM2 and 68Ga-PSMA-11 whole-body images were reconstructed using the baseline scatter algorithm. For comparison, reconstruction was also processed with modified sampling in the single-scatter estimation and with an offset in the scatter tail-scaling process. None of the patients received furosemide to attempt to decrease the accumulation of radiopharmaceuticals in the bladder. The images were scored independently by three blinded reviewers using the 5-point Likert scale.

RESULTS: The scatter algorithm improvements significantly decreased or completely eliminated the washout artifacts. When comparing the baseline and most improved algorithm, the image quality increased and image artifacts were reduced for both 68Ga-RM2 and for 68Ga-PSMA-11 in the kidneys and bladder regions.

CONCLUSION: Image reconstruction with the improved scatter correction algorithm mitigated washout artifacts and recovered diagnostic image quality in 68Ga PET, indicating that the use of diuretics may be avoided.

来源:AJR Am J Roentgenol,查看原文。版权归原作者所有。