使用MDCT洗脱参数表征肾上腺病变:多种中间期与延迟期组合的诊断准确性
前瞻性纳入108例肿瘤患者共129个肾上腺病变,行多期CT(平扫、动脉期、门脉期、5分钟及15分钟延迟期),评估不同洗脱参数的诊断准确性。以40%百分比洗脱阈值从峰值至15分钟延迟期计算,诊断腺瘤总体准确率最高达97.6%(126/129)。若仅有中间期,应获取15分钟延迟扫描以避免准确性下降。
要点
- 平扫衰减<10 HU可正确诊断全部62个富脂腺瘤为良性。
- 峰值衰减在动脉期出现于51/129个病变(39.5%),在门脉期出现于78/129个病变(60.5%)。
- 从峰值至15分钟延迟期计算百分比洗脱,40%阈值诊断腺瘤总体准确率最高达97.6%(126/129)。
核心结论
- 从峰值至15分钟延迟期计算百分比洗脱、阈值40%时诊断腺瘤总体准确率最高(97.6%,126/129个病变正确诊断)。
研究设计与样本
- 前瞻性研究,纳入108例连续肿瘤患者(59男,49女,平均年龄52.6岁)共129个病变,行肾上腺多期CT方案包括平扫、动脉期、门脉期、5分钟及15分钟延迟期;由两名腹部CT经验丰富的放射科医师在不知临床或病理数据下随机共识阅片。
诊断标准与关键数值
- 平扫衰减<10 HU诊断富脂腺瘤;峰值衰减在动脉期出现于51/129个病变(39.5%),在门脉期出现于78/129个病变(60.5%);从峰值至15分钟延迟期计算百分比洗脱、阈值40%时诊断腺瘤总体准确率最高为97.6%(126/129个病变正确诊断)。
临床应用与阅片要点
- 若仅有中间期,应获取15分钟延迟扫描以避免诊断准确性下降;有两个中间期时可用于简化CT日程,避免获取更长的延迟期。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To evaluate the diagnostic accuracy of wash-out parameters calculated using multiple intermediate and delayed phases.
MATERIALS AND METHODS: This prospective study had institutional review board approval and informed consent was obtained from all patients. Between January 2012 and October 2016, 108 consecutive oncologic patients (59 males, 49 females, mean age 52.6 years; 129 diagnosed lesions) underwent multiphasic CT protocol including unenhanced (UE), arterial (AE), portal (PE), 5-min (DE-5) and the 15-min (DE-15) delayed phases of adrenal glands. All images were randomly reviewed in consensus by two radiologists experienced in abdominal CT, unaware of clinical or pathologic data. Location, size and density were recorded. Absolute wash-out, percentage wash-out (PWO) and percentage enhancement wash-out ratio were calculated. The thresholds yielding the best accuracy in differentiating adenomas from nonadenomas were retrospectively determined on the basis of ROC curves. The corresponding diagnostic accuracy values were calculated. Paired sample t test was used to assess differences among imaging parameters within subgroups. Student t test was applied to compare lesions between independent subgroups. p values ≤ 0.05 were considered significant.
RESULTS: The final diagnosis included 82 adenomas (62 lipid-rich and 20 lipid-poor) and 47 nonadenomas (42 metastases, 3 pheochromocytomas, 2 carcinomas). All the 62 lipid-rich adenomas were correctly diagnosed as benign lesions on the basis of their UE attenuation < 10 HU. The PEAK attenuation was achieved during AE phase for 51/129 lesions (39.5%) and at the time of PE phase in 78/129 lesions (60.5%). The best overall accuracy in diagnosing adenomas (97.6%; 126/129 lesions correctly diagnosed) was obtained using 40% threshold for calculating PWO from PEAK to DE-15 scan.
CONCLUSIONS: If only an intermediate phase is available, the 15-min delayed scan should be acquired to avoid any drop in diagnostic accuracy. The availability of two intermediate phase may be used to easy CT schedule by obviating the need to acquire a longer delayed phase.
引用
- Foti G, Malleo G, Faccioli N, et al. Characterization of adrenal lesions using MDCT wash-out parameters: diagnostic accuracy of several combinations of intermediate and delayed phases. Radiol Med. 2018. PMID: 29923085. doi:10.1007/s11547-018-0911-6
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。