文献速递腹部泌尿生殖MR

在1.5 T和3 T场强下使用压缩感知加速磁共振胰胆管成像:一项临床可行性研究

Acceleration of Magnetic Resonance Cholangiopancreatography Using Compressed Sensing at 1.5 and 3 T: A Clinical Feasibility Study.
PubMed 文献 · Invest Radiol · 2018-01-01

本研究在66例临床胰胆系统MRI患者中,于1.5 T和3 T场强下比较导航触发常规三维SPACE-MRCP与压缩感知加速的导航触发及单次屏气MRCP。结果显示压缩感知导航触发MRCP整体图像质量优于常规序列,扫描时间覆盖5% k空间时减少25%至46%;单次屏气压缩感知序列在3 T整体图像质量优于常规序列,在1.5 T则劣于常规序列。

要点

  • 压缩感知导航触发MRCP在1.5 T和3 T整体图像质量均优于常规导航触发序列。
  • 单次屏气压缩感知MRCP在3 T整体图像质量优于常规序列,在1.5 T则劣于常规和压缩感知导航触发序列。
  • 压缩感知加速使扫描时间覆盖5% k空间时减少25%至46%,单次屏气序列覆盖3.6% k空间时减少97%。

核心结论

  • 压缩感知加速MRCP在1.5 T和3 T临床常规中可行,能大幅缩短采集时间;应用单次屏气压缩感知成像时推荐3 T场强。

研究设计与样本

  • 临床可行性研究,共纳入66例临床胰胆系统MRI患者,在1.5 T和3 T场强下采集导航触发常规三维SPACE-MRCP、压缩感知导航触发三维SPACE-MRCP和单次屏气压缩感知三维SPACE-MRCP,由2名独立放射科医师评价图像质量,并做体模测量调整序列参数。

关键影像表现/征象

  • 压缩感知导航触发MRCP整体图像质量在1.5 T优于常规序列(P=0.01)且优于单次屏气压缩感知序列(P<0.001)。
  • 压缩感知导航触发MRCP整体图像质量在3 T优于常规序列(P=0.002)且优于单次屏气压缩感知序列(P=0.013)。
  • 单次屏气压缩感知MRCP整体图像质量在1.5 T劣于常规序列和压缩感知导航触发序列。
  • 单次屏气压缩感知MRCP整体图像质量在3 T优于常规序列(P=0.001)。

诊断标准与关键数值

  • 压缩感知导航触发MRCP在1.5 T和3 T扫描时间覆盖5% k空间时减少25%至46%。
  • 单次屏气压缩感知MRCP在1.5 T和3 T扫描时间覆盖3.6% k空间时减少97%。

临床应用与阅片要点

  • 临床可考虑在1.5 T和3 T使用压缩感知导航触发三维SPACE-MRCP以大幅缩短扫描时间并保持整体图像质量。
  • 单次屏气压缩感知MRCP在3 T整体图像质量优于常规序列,在1.5 T则劣于常规和压缩感知导航触发序列;应用单次屏气压缩感知成像时推荐3 T场强。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Magnetic resonance cholangiopancreatography (MRCP) is an established technique in routine magnetic resonance examination. By applying the compressed sensing (CS) acceleration technique to conventional MRCP sequences, scan time can be markedly reduced. With promising results at 3 T, there is a necessity to evaluate the performance at 1.5 T due to wide scanner availabilities. Aim of this study is to test the feasibility of accelerated 3-dimensional (3D) MRCP with extended sampling perfection with application-optimized contrasts using different flip angle evolution (SPACE) using CS in navigator triggering and in a single breath-hold in a clinical setting at 1.5 T and 3 T and compare it with a conventional navigator-triggered 3D SPACE-MRCP.

MATERIALS AND METHODS: Phantom measurements were performed to adapt sequence parameters. Conventional 3D SPACE-MRCP in navigator triggering (STD_MRCP) as well as CS-accelerated 3D SPACE-MRCP acquired in navigator triggering and in a single breath-hold (CS_MRCP and CS_BH_MRCP) was performed in 66 patients undergoing clinically induced MRI of the pancreatobiliary system at 1.5 T and 3 T. Image quality evaluation was performed by 2 independent radiologists. Dedicated statistics were performed (P < 0.05 considered significant).

RESULTS: In patient imaging, CS_MRCP was superior to STD_MRCP and CS_BH_MRCP in aspects of overall image quality at 1.5 T (P = 0.01; P < 0.001) and 3 T (P = 0.002; P = 0.013). Overall image quality in CS_BH_MRCP was inferior compared with STD_MRCP and CS_MRCP at 1.5 T. At 3 T, overall image quality in CS_BH_MRCP was superior to STD_MRCP (P = 0.001). Scan time was reduced by 25% to 46% covering 5% of k-space (CS_MRCP at 1.5 and 3 T) and 97% covering 3.6% of k-space (CS_BH_MRCP at 1.5 and 3 T).

CONCLUSIONS: Compressed sensing-accelerated MRCP is feasible in clinical routine at 1.5 and 3 T offering major reduction of acquisition time. When applying a single breath-hold CS imaging, field strengths of 3 T are recommended.

来源:Invest Radiol,查看原文。版权归原作者所有。

引用

  1. Taron J, Weiss J, Notohamiprodjo M, et al. Acceleration of Magnetic Resonance Cholangiopancreatography Using Compressed Sensing at 1.5 and 3 T: A Clinical Feasibility Study. Invest Radiol. 2018. PMID: 29889672. doi:10.1097/RLI.0000000000000489

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。