本Meta分析纳入11项研究共910例慢性病毒性肝病患者,比较瞬时弹性成像肝脏硬度值约13.6 kPa、18 kPa和22 kPa三个界值诊断临床显著门静脉高压的效能。约13.6 kPa汇总敏感度0.96、特异度0.60,约22 kPa汇总敏感度0.74、特异度0.94;约13.6 kPa(高敏感度)和约22 kPa(高特异度)可分别用作筛查和确认工具,总体以约22 kPa效能最佳。

要点

  • 约13.6 kPa界值敏感度0.96,可有效排除临床显著门静脉高压。
  • 约22 kPa界值特异度0.94,可有效确认临床显著门静脉高压。
  • 三个界值中约22 kPa总体诊断效能最佳。

核心结论

  • 约13.6 kPa(高敏感度)和约22 kPa(高特异度)可分别作为慢性病毒性肝病临床显著门静脉高压诊断的筛查和确认工具,总体以约22 kPa界值效能最佳。

研究设计与样本

  • Meta分析,检索PubMed、Ovid、Web of Science和Cochrane Library数据库,纳入11项研究共910例慢性病毒性肝病患者,提取各研究约13.6 kPa、18 kPa和22 kPa界值的诊断数据,采用双变量模型估计汇总敏感度、特异度、阳性似然比和阴性似然比。

诊断标准与关键数值

  • 约13.6 kPa界值:汇总敏感度0.96(95%CI 0.93-0.97)、特异度0.60(95%CI 0.47-0.75)、LR+ 2.4(95%CI 1.6-3.7)、LR- 0.07(95%CI 0.04-0.13)。约18 kPa界值:汇总敏感度0.85(95%CI 0.81-0.89)、特异度0.80(95%CI 0.71-0.87)、LR+ 4.4(95%CI 2.9-6.8)、LR- 0.17(95%CI 0.12-0.25)。约22 kPa界值:汇总敏感度0.74(95%CI 0.66-0.80)、特异度0.94(95%CI 0.86-0.97)、LR+ 11.5(95%CI 5.5-23.5)、LR- 0.28(95%CI 0.22-0.36)。

临床应用与阅片要点

  • 作者认为约13.6 kPa界值可有效排除临床显著门静脉高压,约22 kPa界值可有效确认临床显著门静脉高压,二者可分别用作筛查和确认工具,约22 kPa界值总体效能最佳。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: Transient elastography-based liver stiffness value (TE-LSV) has been investigated for assessing clinically significant portal hypertension (CSPH). The aetiology of CSPH is an important factor determining TE-LSV. There is insufficient evidence for selecting cut-off values.

AIMS: This study performed a meta-analysis to compare the three most widely used cut-off values (around 13.6 kPa, 18 kPa and 22kPa) of TE-LSV for the diagnosis of CSPH in patients with chronic viral liver disease.

METHODS: The PubMed, Ovid, Web of Science and Cochrane Library databases were searched. Diagnostic data for cut-off values around 13.6 kPa, 18 kPa and 22 kPa in each included study were extracted. The bivariate model was performed to estimate pooled sensitivity, specificity, positive likelihood ratio (LR+) and negative likelihood ratio (LR-).

RESULTS: Eleven studies assessing 910 patients were included in this meta-analysis. Pooled sensitivities of cut-off values around 13.6 kPa, 18 kPa and 22 kPa were 0.96 (95% CI 0.93-0.97), 0.85 (0.81-0.89) and 0.74 (0.66-0.80), respectively; pooled specificities were 0.60 (0.47-0.75), 0.80 (0.71-0.87) and 0.94 (0.86-0.97), respectively. Pooled LR+ values were 2.4 (1.6-3.7), 4.4 (2.9-6.8) and 11.5 (5.5-23.5) for cut-off values around 13.6 kPa, 18 kPa and 22 kPa, respectively, for pooled LR- values of 0.07 (0.04-0.13), 0.17 (0.12-0.25) and 0.28 (0.22-0.36), respectively.

CONCLUSION: Cut-off values around 13.6 kPa (high sensitivity) and 22 kPa (high specificity) could be used as screening and confirmation tools, respectively, in the diagnosis of CSPH. Overall, the cut-off value around 22 kPa showed the best performance.

KEY POINTS: Transient elastography-based liver stiffness could be used to diagnose portal hypertension. Comparison of certain cut-off values would provide more information for clinical decision-making. Cut-off around 13.6 kPa was able to exclude clinically significant portal hypertension (CSPH) effectively. Cut-off around 22 kPa was able to confirm CSPH effectively.