文献速递腹部技术与安全CT

双能CT在腹部恶性淋巴瘤患者中的应用:噪声优化虚拟单能成像对客观与主观图像质量的影响

Dual-energy CT in patients with abdominal malignant lymphoma: impact of noise-optimised virtual monoenergetic imaging on objective and subjective image quality.
PubMed 文献 · Clin Radiol · 2018-06-05

回顾性纳入35例经组织学证实的腹部恶性淋巴瘤患者,在腹部双能CT中比较标准线性融合、传统虚拟单能成像与噪声优化虚拟单能成像(VMI+)40–100 keV的图像质量。VMI+在40 keV时客观信噪比和对比噪声比最高,60 keV VMI+主观图像质量最佳,40 keV VMI+病灶 delineation 评分最高,100 keV VMI+主观噪声最低。

要点

  • 40 keV VMI+的SNR 15.77±7.74、CNR 18.27±8.04,高于标准线性融合M_0.6的SNR 7.96±3.26、CNR 13.55±3.47(p<0.001)。
  • 60 keV VMI+主观图像质量评分中位数5分,优于其他所有图像系列(p<0.001)。
  • 40 keV VMI+病灶 delineation 评分中位数最高(5分),100 keV VMI+主观噪声最低(中位数5分)。

核心结论

  • 低 keV VMI+重建较标准图像重建和传统VMI可改善腹部双能CT中恶性淋巴瘤病灶的图像质量和病灶 delineation。

研究设计与样本

  • 回顾性研究,连续纳入35例经组织学证实的腹部恶性淋巴瘤患者(平均年龄53.8±18.6岁,范围21–82岁),行腹部双能CT检查;图像经标准线性融合(M_0.6)、传统VMI和VMI+技术以40–100 keV(每10 keV递增)后处理;由三名盲法观察者用五点李克特量表主观评分。

关键影像表现/征象

  • 淋巴瘤病灶的SNR和CNR在40 keV VMI+达到峰值(SNR 15.77±7.74;CNR 18.27±8.04)。
  • 标准线性融合M_0.6的SNR为7.96±3.26、CNR为13.55±3.47。
  • 40 keV VMI+的SNR和CNR与标准线性融合M_0.6及所有传统VMI系列相比差异有统计学意义(p<0.001)。

诊断标准与关键数值

  • 客观图像质量以淋巴瘤病灶的SNR和CNR衡量,40 keV VMI+的SNR 15.77±7.74、CNR 18.27±8.04为峰值。
  • 主观图像质量、病灶 delineation 和图像噪声采用五点李克特量表由三名盲法观察者评分。
  • 60 keV VMI+主观图像质量评分中位数5分,优于其他所有图像系列(p<0.001)。
  • 40 keV VMI+病灶 delineation 评分中位数最高(5分),100 keV VMI+主观图像噪声最低(中位数5分)。

临床应用与阅片要点

  • 在腹部双能CT评估恶性淋巴瘤时,低 keV VMI+重建(40 keV)可提高病灶SNR、CNR和 delineation 评分。
  • 60 keV VMI+获得最佳主观图像质量评分,100 keV VMI+主观噪声最低,可根据阅片目的选择不同 keV 的VMI+重建。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To investigate the impact of noise-optimised virtual monoenergetic imaging (VMI+) reconstructions on quantitative and qualitative image parameters in patients with malignant lymphoma at dual-energy computed tomography (DECT) examinations of the abdomen.

MATERIALS AND METHODS: Thirty-five consecutive patients (mean age, 53.8±18.6 years; range, 21-82 years) with histologically proven malignant lymphoma of the abdomen were included retrospectively. Images were post-processed with standard linear blending (M_0.6), traditional VMI, and VMI+ technique at energy levels ranging from 40 to 100 keV in 10 keV increments. Signal-to-noise (SNR) and contrast-to-noise ratios (CNR) were objectively measured in lymphoma lesions. Image quality, lesion delineation, and image noise were rated subjectively by three blinded observers using five-point Likert scales.

RESULTS: Quantitative image quality parameters peaked at 40-keV VMI+ (SNR, 15.77±7.74; CNR, 18.27±8.04) with significant differences compared to standard linearly blended M_0.6 (SNR, 7.96±3.26; CNR, 13.55±3.47) and all traditional VMI series (p<0.001). Qualitative image quality assessment revealed significantly superior ratings for image quality at 60-keV VMI+ (median, 5) in comparison with all other image series (p<0.001). Assessment of lesion delineation showed the highest rating scores for 40-keV VMI+ series (median, 5), while lowest subjective image noise was found for 100-keV VMI+ reconstructions (median, 5).

CONCLUSION: Low-keV VMI+ reconstructions led to improved image quality and lesion delineation of malignant lymphoma lesions compared to standard image reconstruction and traditional VMI at abdominal DECT examinations.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Lenga L, Czwikla R, Wichmann JL, et al. Dual-energy CT in patients with abdominal malignant lymphoma: impact of noise-optimised virtual monoenergetic imaging on objective and subjective image quality. Clin Radiol. 2018. PMID: 29884524. doi:10.1016/j.crad.2018.04.015

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。