文献速递外周血管技术与安全CTPET

18F-FDG PET-CT与增强CT在疑似大血管血管炎诊断中的效果比较

Comparative effectiveness of 18F-FDG PET-CT and contrast-enhanced CT in the diagnosis of suspected large-vessel vasculitis.
PubMed 文献 · Br J Radiol · 2018-07-05

该回顾性数据库研究纳入2011至2016年间接受增强CT和PET-CT检查的36例成人(17例大血管血管炎、19例对照),比较两种检查的诊断准确性。PET-CT的SUVmax的AUC为0.95(95%CI 0.88-1.00),增强CT壁增厚的AUC为0.83(95%CI 0.66-0.99),两者参数显著相关(p<0.0001,R=0.62)。作者认为FDG PET-CT准确性极好,增强CT壁增厚准确性良好,在无PET-CT或患者不适合PET-CT时增强CT是可行替代。

要点

  • 大血管血管炎与对照的SUVmax均值差为1.6(95%CI 1.1-2.0),壁增厚均值差为1.25 mm(95%CI 0.68-1.83 mm)。
  • SUVmax与壁增厚显著相关(p<0.0001,R=0.62)。
  • SUVmax的AUC为0.95(95%CI 0.88-1.00),壁增厚的AUC为0.83(95%CI 0.66-0.99)。

核心结论

  • FDG PET-CT在诊断大血管血管炎方面准确性极好,而增强CT壁增厚准确性良好,两者参数高度显著相关。
  • 在无FDG PET-CT设备的医院或患者不适合PET-CT(如未控制的糖尿病)时,增强CT为评估大血管血管炎提供了可行替代。
  • 主动脉与肝脏SUVmax比值是大血管血管炎最具特异性的参数。

研究设计与样本

  • 回顾性数据库审查,纳入2011至2016年间接受增强CT和PET-CT检查的大血管血管炎患者,共36例成人(17例大血管血管炎、19例对照),平均年龄63岁(范围38-89岁),其中男性17例(47%)。
  • CT与PET检查间隔时间均值(标准差)为1.9(1.2)个月。

诊断标准与关键数值

  • SUVmax在大血管血管炎与对照之间差异显著,均值差(95%CI)为1.6(1.1,2.0)。
  • 壁增厚在大血管血管炎与对照之间差异显著,均值差(95%CI)为1.25(0.68,1.83)mm。
  • SUVmax的AUC(95%CI)为0.95(0.88-1.00),壁增厚的AUC(95%CI)为0.83(0.66-0.99)。
  • SUVmax与壁增厚显著相关(p<0.0001,R=0.62)。
  • 主动脉与肝脏FDG摄取比值是大血管血管炎最具特异性的参数。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: Large-vessel vasculitis (LVV) is a serious illness with potentially life-threatening consequences. (18Fluorine) fluorodeoxyglucose positron emission tomography-computed tomography (18F-FDG PET-CT) has emerged as a valuable diagnostic tool in suspected LVV, combining the strengths of functional and structural imaging. This study aimed to compare the accuracy of FDG PET-CT and contrast-enhanced CT (CECT) in the evaluation of patients with LVV.

METHODS: A retrospective database review for LVV patients undergoing CECT and PET-CT between 2011 to 2016 yielded demographics, scan interval and vasculitis type. Qualitative and quantitative PET-CT analyses included aorta:liver FDG uptake, bespoke FDG uptake distribution scores and vascular maximum standardised uptake values (SUVmax). Quantitative CECT data were assessed for wall thickness and mural-lumen ratio. Receiver operating characteristics (ROC) curves were constructed to evaluate comparative diagnostic accuracy and a correlational analysis was conducted between SUVmax and wall thickness.

RESULTS: 36 adults (17 LVV, 19 controls) with a mean age (range) 63 (38-89) years, of which 17 (47%) were males were included. Time interval between CT and PET was mean [standard deviation (SD)] 1.9 (1.2) months. Both SUVmax and wall thickness demonstrated a significant difference between LVV and controls, with a mean difference [95%confidence interval (CI)] for SUVmax 1.6 (1.1, 2.0) and wall thickness 1.25 (0.68, 1.83) mm, respectively. These two parameters were significantly correlated (p < 0.0001, R = 0.62). The area under the curve (AUC) (95% CI) for SUVmax was 0.95 (0.88-1.00), and for mural thickening was 0.83 (0.66-0.99).

CONCLUSION: FDG PET-CT demonstrated excellent accuracy whilst CECT mural thickening showed good accuracy in the diagnosis of LVV. Both parameters showed a highly significant correlation. In hospitals without access to FDG PET-CT or in patients unsuitable for PET-CT (e.g. uncontrolled diabetes) CECT offers a viable alternative for the assessment of LVV. Advances in knowledge: FDG PET-CT is a highly accurate test for the diagnosis of LVV. Aorta:liver SUVmax ratio is the most specific parameter for LVV. In hospitals without PET-CT or in unsuitable patients e.g. diabetics, CECT is a viable alternative.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Vaidyanathan S, Chattopadhyay A, Mackie SL, et al. Comparative effectiveness of 18F-FDG PET-CT and contrast-enhanced CT in the diagnosis of suspected large-vessel vasculitis. Br J Radiol. 2018. PMID: 29927635. doi:10.1259/bjr.20180247