文献速递腹部MR

实性胰腺肿块的体素内不相干运动扩散加权MR成像:测量的可靠性与定性价值

Intravoxel incoherent motion diffusion-weighted MR imaging of solid pancreatic masses: reliability and usefulness for characterization.
PubMed 文献 · Abdom Radiol (NY) · 2019-01-01

本研究纳入57例实性胰腺病变患者(34例胰腺导管腺癌、18例胰腺神经内分泌肿瘤、5例自身免疫性胰腺炎)和50例正常胰腺受试者,行1.5T MR IVIM-DWI检查。IVIM参数观察者间一致性优秀(ICC 0.860–0.983),D、Dp、f在胰腺导管腺癌与胰腺神经内分泌肿瘤间有显著差异,但ROC曲线两两比较无显著差异;f在自身免疫性胰腺炎高于胰腺导管腺癌(AUC=0.735)。作者认为IVIM参数可靠性优秀,可能有助于鉴别实性胰腺病变与正常胰腺。

要点

  • IVIM参数ADC、D、Dp、f的观察者间一致性均优秀,ICC分别为0.860、0.937、0.968、0.983。
  • D、Dp、f在胰腺导管腺癌与胰腺神经内分泌肿瘤间有显著差异,但ROC曲线两两比较无显著差异(p=0.08–0.74)。
  • f在自身免疫性胰腺炎高于胰腺导管腺癌(p=0.024,AUC=0.735)。

核心结论

  • IVIM衍生参数具有优秀的可靠性,可能有助于鉴别实性胰腺病变与正常胰腺。

研究设计与样本

  • 前瞻性纳入57例实性胰腺病变患者(34例胰腺导管腺癌、18例胰腺神经内分泌肿瘤、5例自身免疫性胰腺炎)和50例正常胰腺受试者,行1.5T MR IVIM-DWI检查,由两名独立阅片者分析。

诊断标准与关键数值

  • 观察者间一致性ICC:ADC为0.860,D为0.937,Dp为0.968,f为0.983。
  • D、Dp、f在胰腺导管腺癌与胰腺神经内分泌肿瘤间差异显著(p分别为0.002、<0.001、<0.001),但ROC曲线两两比较无显著差异(p=0.08–0.74)。
  • f在自身免疫性胰腺炎高于胰腺导管腺癌(p=0.024;AUC=0.735)。
  • Dp和f在胰腺神经内分泌肿瘤高于自身免疫性胰腺炎(p=0.029和0.023),ROC分析无差异(p=0.07)。

临床应用与阅片要点

  • IVIM-DWI参数ADC、D、Dp、f的测量观察者间一致性优秀,可用于日常定量评估。
  • D、Dp、f在胰腺导管腺癌与胰腺神经内分泌肿瘤间有显著差异,但单个参数鉴别诊断的ROC曲线两两比较无显著差异。
  • f在自身免疫性胰腺炎高于胰腺导管腺癌(AUC=0.735),可能有助于鉴别。
  • Dp和f在胰腺神经内分泌肿瘤高于自身免疫性胰腺炎(p=0.029和0.023),ROC分析无差异(p=0.07)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: IVIM-DW imaging has shown potential usefulness in the study of pancreatic lesions. Controversial results are available regarding the reliability of the measurements of IVIM-derived parameters. The aim of this study was to evaluate the reliability and the diagnostic potential of IVIM-derived parameters in differentiation among focal solid pancreatic lesions and normal pancreas (NP).

METHODS: Fifty-seven patients (34 carcinomas-PDACs, 18 neuroendocrine neoplasms-panNENs, and 5 autoimmune pancreatitis-AIP) and 50 subjects with NP underwent 1.5-T MR imaging including IVIM-DWI. Images were analyzed by two independent readers. Apparent diffusion coefficient (ADC), slow component of diffusion (D), incoherent microcirculation (Dp), and perfusion fraction (f) were calculated. Interobserver reliability was assessed with intraclass correlation coefficient (ICC). A Kruskal-Wallis H test with Steel-Dwass post hoc test was used for comparison. The diagnostic performance of each parameter was evaluated through receiver operating characteristic (ROC) curve analysis.

RESULTS: Overall interobserver agreement was excellent (ICC = 0.860, 0.937, 0.968, and 0.983 for ADC, D, Dp, and f). D, Dp, and f significantly differed among PDACs and panNENs (p = 0.002, < 0.001, and < 0.001), albeit without significant difference at the pairwise comparison of ROC curves (p = 0.08-0.74). Perfusion fraction was higher in AIP compared with PDACs (p = 0.024; AUC = 0.735). Dp and f were higher in panNENs compared with AIP (p = 0.029 and 0.023), without differences at ROC analysis (p = 0.07).

CONCLUSIONS: IVIM-derived parameters have excellent reliability and could help in differentiation among solid pancreatic lesions and NP.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. De Robertis R, Cardobi N, Ortolani S, et al. Intravoxel incoherent motion diffusion-weighted MR imaging of solid pancreatic masses: reliability and usefulness for characterization. Abdom Radiol (NY). 2019. PMID: 29951899. doi:10.1007/s00261-018-1684-z

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。