文献速递腹部外周血管CT

双能CT碘图与40千电子伏单能图像在急性肠缺血诊断中的应用

Dual-Energy CT Iodine Mapping and 40-keV Monoenergetic Applications in the Diagnosis of Acute Bowel Ischemia.
PubMed 文献 · AJR Am J Roentgenol · 2018-06-21

本研究回顾性纳入60例疑似急性肠缺血患者,评估双能CT碘图及40千电子伏单能图像对急性肠缺血的诊断效能。结果显示,补充碘图和40千电子伏图像可提高阅片者A的敏感度(分别至81.8%和100%),减少阅片者B的假阳性,并改善观察者间一致性;定量分析显示缺血段与非缺血段的碘摄取和平均衰减存在显著差异。

要点

  • 补充碘图和40千电子伏单能图像可提高急性肠缺血的检出敏感度。
  • 碘图和40千电子伏图像可减少假阳性并改善观察者间一致性。
  • 缺血段碘摄取和平均衰减显著高于非缺血段。

核心结论

  • 碘图和40千电子伏单能图像增加急性肠缺血的可见性,与单独常规CT相比提高诊断准确性。

研究设计与样本

  • 回顾性研究,纳入60例连续疑似急性肠缺血患者,在26个月期间接受标准化双源双能CT协议;以临床和手术结果为参考标准;两名腹部放射科医师独立评估。

关键影像表现/征象

  • 缺血段碘摄取为1.01 ± 0.55 mg/mL,非缺血段为3.04 ± 1.19 mg/mL。
  • 缺血段平均衰减为75.2 ± 38.4 HU,非缺血段为163.5 ± 48.9 HU。

诊断标准与关键数值

  • 阅片者A常规图像敏感度63.6%(95% CI,30.8-89.1%),补充碘图后81.8%(95% CI,48.2-97.7%),补充40千电子伏图像后100%(95% CI,71.5-100%)。
  • 阅片者B两种技术均未见敏感度变化,但补充碘图和40千电子伏图像后假阳性减少。
  • 观察者间一致性常规图像为fair(κ = 0.29),碘图为moderate(κ = 0.45),40千电子伏图像为substantial(κ = 0.63)。

临床应用与阅片要点

  • 在疑似急性肠缺血时,可补充碘图和40千电子伏单能图像以提高诊断信心。
  • 定量ROI分析有助于区分缺血与非缺血肠段。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: Sensitivity of CT of the abdomen for detection of acute bowel ischemia (ABI) can be as low as 60%. In this study, we assessed the diagnostic performance of iodine-map and monoenergetic (40-keV) images in patients with suspected ABI.

MATERIALS AND METHODS: This retrospective study included 60 consecutive patients with suspected ABI who underwent a standardized imaging protocol dual-source dual-energy CT (DECT) over a 26-month period. Clinical and operative outcomes were recorded as the reference standard. Two abdominal radiologists who were unaware of clinical and surgical information independently assessed conventional CT images for ABI. After a time interval designed to reduce recall, readers reassessed conventional images with supplementary iodine-map and 40-keV postprocessed images. Quantitative ROI analysis was also performed.

RESULTS: ABI was observed in 11 patients. For reader A, sensitivity was 63.6% (95% CI, 30.8-89.1%) when interpreting conventional images alone. Sensitivity for detection of ABI increased to 81.8% (95% CI, 48.2-97.7%) and 100% (95% CI, 71.5-100%) when iodine-map and 40-keV images were assessed, respectively. For reader B, no change in sensitivity was seen with either technique, but the number of false-positives were reduced with supplementary iodine-map and 40-keV postprocessed images. Interobserver agreement was fair with conventional images (κ = 0.29) but improved to moderate (κ = 0.45) and substantial (κ = 0.63) with iodine-map and 40-keV images, respectively. Quantitative assessment found significant differences in iodine uptake (1.01 ± 0.55 mg/mL vs 3.04 ± 1.19 mg/mL) and mean attenuation (75.2 ± 38.4 HU vs 163.5 ± 48.9 HU) between nonischemic and ischemic segments, respectively.

CONCLUSION: Iodine-map and 40-keV monoenergetic images increase conspicuity of ABI, resulting in improved diagnostic accuracy compared with review of conventional CT images alone.

来源:AJR Am J Roentgenol,查看原文。版权归原作者所有。

引用

  1. Lourenco PDM, Rawski R, Mohammed MF, et al. Dual-Energy CT Iodine Mapping and 40-keV Monoenergetic Applications in the Diagnosis of Acute Bowel Ischemia. AJR Am J Roentgenol. 2018. PMID: 29927328. doi:10.2214/AJR.18.19554

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。