hepatic steatosis 超声特征的读者一致性与准确性评估
本前瞻性研究纳入45例已知或疑似肝脂肪变性成人,8名读者独立对8项超声特征及整体印象进行评分,评估读者内、探头间及读者间一致性,并用CART分析筛选预测组织学脂肪变性的特征。结果显示肝大静脉模糊、肝肾对比及整体印象一致性最高,CART仅选择肝大静脉模糊,其分类准确性与整体印象相似(74%~75% vs 68%~72%)。
要点
- 肝大静脉模糊、肝肾对比及整体印象的读者一致性最高。
- CART决策规则仅选择肝大静脉模糊预测二分类组织学脂肪变性。
- 肝大静脉模糊的分类准确性与放射科医生整体印象相似(74%~75% vs 68%~72%)。
核心结论
- 肝大静脉模糊、肝肾对比及整体印象的读者一致性最高;肝大静脉模糊可能对二分类肝脂肪变性分级提供最高的分类准确性。
研究设计与样本
- IRB批准、HIPAA合规的前瞻性研究,纳入45例已知或疑似肝脂肪变性成人(18男、27女,平均年龄56±12岁),2015年9月至2016年7月扫描,使用Siemens S3000超声仪及6C1HD、4C1探头,由经验丰富的超声技师按标准方案采集图像,8名读者独立评分,以组织学脂肪变性为参考标准。
诊断标准与关键数值
- 读者内ICC范围0.430~0.777,探头间ICC范围0.228~0.640,读者间ICC范围0.014~0.561;CART决策规则仅选择肝大静脉模糊,其分类准确性为74%~75%,放射科医生整体印象的准确性为68%~72%。
临床应用与阅片要点
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: The purpose of the study is to assess the reader agreement and accuracy of eight ultrasound imaging features for classifying hepatic steatosis in adults with known or suspected hepatic steatosis.
METHODS: This was an IRB-approved, HIPAA-compliant prospective study of adult patients with known or suspected hepatic steatosis. All patients signed written informed consent. Ultrasound images (Siemens S3000, 6C1HD, and 4C1 transducers) were acquired by experienced sonographers following a standard protocol. Eight readers independently graded eight features and their overall impression of hepatic steatosis on ordinal scales using an electronic case report form. Duplicated images from the 6C1HD transducer were read twice to assess intra-reader agreement. Intra-reader, inter-transducer, and inter-reader agreement were assessed using intraclass correlation coefficients (ICC). Features with the highest intra-reader agreement were selected as predictors for dichotomized histological steatosis using Classification and Regression Tree (CART) analysis, and the accuracy of the decision rule was compared to the accuracy of the radiologists' overall impression.
RESULTS: 45 patients (18 males, 27 females; mean age 56 ± 12 years) scanned from September 2015 to July 2016 were included. Mean intra-reader ICCs ranged from 0.430 to 0.777, inter-transducer ICCs ranged from 0.228 to 0.640, and inter-reader ICCs ranged from 0.014 to 0.561. The CART decision rule selected only large hepatic vein blurring and achieved similar accuracy to the overall impression (74% to 75% and 68% to 72%, respectively).
CONCLUSIONS: Large hepatic vein blurring, liver-kidney contrast, and overall impression provided the highest reader agreement. Large hepatic vein blurring may provide the highest classification accuracy for dichotomized grading of hepatic steatosis.
引用
- Hong CW, Marsh A, Wolfson T, et al. Reader agreement and accuracy of ultrasound features for hepatic steatosis. Abdom Radiol (NY). 2019. PMID: 29951900. doi:10.1007/s00261-018-1683-0
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。