二叶式主动脉瓣患者TAVR术前瓣环尺寸测量:CT面积推导周长与术中测量相关性最佳
本研究纳入104例经术前筛查拟行TAVR但最终接受外科手术并术中直接测量瓣环的二叶式主动脉瓣患者,比较2DTTE、3DTEE、CT面积推导周长(CTarea)、CT周长推导直径(CTperi)和CT平均直径(CTmean)五种方法与术中测量的相关性和一致性。结果显示CTarea相关性最高(r=0.932)且一致性最佳,CTperi易高估瓣膜选择,3DTEE在不宜CT者中表现优越但瓣环钙化时需谨慎。
要点
- CT面积推导周长(CTarea)与术中瓣环测量相关性最高(r=0.932),一致性最佳。
- CT周长推导直径(CTperi)易高估外科瓣膜选择26.9%、TAVR瓣膜选择36.5%。
- 3DTEE在不宜CT的二叶式主动脉瓣患者中瓣环测量表现优越,但瓣环钙化时需谨慎。
核心结论
- CT面积推导周长(CTarea)是二叶式主动脉瓣瓣环尺寸测量和瓣膜选择的最佳方法,应纳入二叶式主动脉瓣专用的瓣环尺寸测量推荐;CTperi的不足在于高估外科或TAVR瓣膜选择;3DTEE在不宜CT的患者中表现优越,但瓣环钙化时因部分声影可能导致图像不准确而需谨慎使用。
研究设计与样本
- 研究纳入104例经术前筛查拟行TAVR但最终接受外科手术并术中直接测量瓣环的二叶式主动脉瓣患者,比较2DTTE、3DTEE、CT面积推导周长(CTarea)、CT周长推导直径(CTperi)和CT平均直径(CTmean)五种方法与术中测量的相关性和一致性,并分析五种方法理论瓣膜选择与术中测量的一致性。
诊断标准与关键数值
- CTarea与术中测量的相关性最高(r=0.932),一致性最佳。
- CTarea的理论瓣膜选择与术中测量一致率:外科瓣膜84.6%(κ=0.791),TAVR瓣膜74.0%(κ=0.585)。
- CTperi的理论瓣膜选择导致高估:外科瓣膜26.9%(κ=0.589),TAVR瓣膜36.5%(κ=0.425)。
- 无论主动脉瓣钙化主要部位如何,CT测量与术中测量均呈良好相关性(r=0.860-0.953)。
临床应用与阅片要点
- 二叶式主动脉瓣患者TAVR术前瓣环尺寸测量可优先采用CT面积推导周长(CTarea)。
- CT周长推导直径(CTperi)易高估外科或TAVR瓣膜选择,阅片报告时需注意。
- 不宜CT的二叶式主动脉瓣患者可采用3DTEE测量瓣环,但瓣环钙化时因部分声影可能导致图像不准确,需谨慎使用。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To clarify the optimal measurements for patients with bicuspid aortic valve (BAV) preferred for transcatheter aortic valve replacement (TAVR), our study compared intraoperative sizing with five different approaches by transthoracic echocardiography (TTE), three-dimensional transesophageal echocardiography (3DTEE) and computed tomography (CT).
METHODS: We enrolled 104 BAV patients prescreened for TAVR but who underwent surgery with direct intraoperative annulus sizing. All five approaches [2DTTE, 3DTEE, area-derived perimeter (CTarea), perimeter-derived diameter (CTperi) and mean diameter (CTmean)] were compared with intraoperative sizing, respectively. Agreements on theoretical valve selections by five methods with those by intraoperative sizing were analyzed.
RESULTS: CTarea showed the highest correlation (r = 0.932) and the best agreement with intraoperative sizing. Agreement for theoretical surgical and TAVR prosthesis selection was found in 84.6% and 74.0% BAVs by CTarea (κ = 0.791, κ = 0.585). CTperi-based prosthesis selection led to overestimation of 26.9% for surgical valves (κ = 0.589) and 36.5% for TAVR valves (κ = 0.425). Good correlations were observed between CT measurements and intraoperative sizing regardless of the predominant site of aortic valve calcification (r = 0.860-0.953).
CONCLUSION: The CTarea, which demonstrated the optimal approach to annulus sizing and prosthesis choice of BAVs with high eccentricity, should be included into the BAV-specific annulus sizing recommendation. The insufficiency of CTperi lay in overestimation of surgical or TAVR valve selections. Good agreement of 3DTEE sizing proved its superiority in annulus sizing for BAVs unsuitable for CT, but it should be used with caution for patients with a calcified annulus, where partial acoustic shadowing could lead to image inaccuracy.
KEY POINTS: • The area-derived perimeter by CT is the optimal approach to annulus sizing of BAVs. • The perimeter-derived approach is prone to overestimation of BAVs. • 3DTEE showed its superiority in annulus sizing for BAVs unsuitable for CT, but it should be used with caution in patients with a calcified annulus.
引用
- Wang Y, Wang M, Song G, et al. Optimal pre-TAVR annulus sizing in patients with bicuspid aortic valve: area-derived perimeter by CT is the best-correlated measure with intraoperative sizing. Eur Radiol. 2018. PMID: 29926206. doi:10.1007/s00330-018-5592-y
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。