文献速递心血管CT

采用新型自动三维右心室容积分割方法评估冠状动脉计算机断层扫描血管造影的右心室功能:一项验证研究

Evaluation of right ventricular function by coronary computed tomography angiography using a novel automated 3D right ventricle volume segmentation approach: a validation study.
PubMed 文献 · Eur Radiol · 2018-06-04

本研究纳入26例左心室射血分数低于35%的严重终末期心力衰竭患者,采用个体化双相对比剂注射方案行冠状动脉CTA,并用新型自动三维右心室容积分割工具测量右心室功能。结果显示分割成功率100%,读图时间3分33秒,CTA右心室射血分数与右心房压力相关性(r=-0.595)强于与三尖瓣环收缩期位移的相关性(r=0.366),观察者间相关性高。

要点

  • 自动三维右心室容积分割在26例患者中全部成功,读图时间3分33秒。
  • CTA右心室射血分数与右心房压力相关性r=-0.595(p=0.006),强于与三尖瓣环收缩期位移的相关性r=0.366。
  • 双相对比剂注射方案使右心房和右心室CT衰减分别为196.9±75.3 HU和217.5±76.1 HU。

核心结论

  • 使用新型三维容积分割工具并通过专用双相注射方案,CTA测量右心室功能快速且可靠,CTA右心室射血分数比经胸超声心动图三尖瓣环收缩期位移更接近右心房压力的替代指标。

研究设计与样本

  • 验证研究,纳入26例左心室射血分数低于35%的严重终末期心力衰竭并转诊行CTA的患者,采用个体化双相对比剂注射方案(80%/20%高/低流速),以经胸超声心动图三尖瓣环收缩期位移和右心侵入性导管检查为参考。

关键影像表现/征象

  • 自动三维右心室容积分割在26例(100%)患者中成功。
  • 读图时间为3分33秒(范围1分50秒至4分33秒)。
  • 右心房和右心室CT衰减分别为196.9±75.3 HU和217.5±76.1 HU。
  • CTA右心室射血分数与右心房压力呈负相关(r=-0.595;p=0.006),与三尖瓣环收缩期位移相关性较弱(r=0.366,p=0.94)。
  • 三尖瓣环收缩期位移与右心房压力呈弱至中度负相关但无统计学显著性(r=-0.317,p=0.231)。

诊断标准与关键数值

  • 右心室舒张末期容积观察者间相关性r=0.96(p<0.001)。
  • 右心室收缩末期容积观察者间相关性r=0.86(p<0.001)。
  • 右心室射血分数观察者间相关性r=0.72(p=0.001)。

临床应用与阅片要点

  • 采用个体化双相对比剂注射方案(80%/20%高/低流速)可确保右心室对比剂衰减均匀。
  • 自动三维右心室容积分割工具测量右心室功能快速且可靠,可作为右心室功能评估的替代方法。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To evaluate right ventricle (RV) function by coronary computed tomography angiography (CTA) using a novel automated three-dimensional (3D) RV volume segmentation tool in comparison with clinical reference modalities.

METHODS: Twenty-six patients with severe end-stage heart failure [left ventricle (LV) ejection fraction (EF) <35%] referred to CTA were enrolled. A specific individually tailored biphasic contrast agent injection protocol was designed (80%/20% high/low flow) was designed. Measurement of RV function [EF, end-diastolic volume (EDV), end-systolic volume (ESV)] by CTA was compared with tricuspid annular plane systolic excursion (TAPSE) by transthoracic echocardiography (TTE) and right heart invasive catheterisation (IC).

RESULTS: Automated 3D RV volume segmentation was successful in 26 (100%) patients. Read-out time was 3 min 33 s (range, 1 min 50s-4 min 33s). RV EF by CTA was stronger correlated with right atrial pressure (RAP) by IC (r = -0.595; p = 0.006) but weaker with TAPSE (r = 0.366, p = 0.94). When comparing TAPSE with RAP by IC (r = -0.317, p = 0.231), a weak-to-moderate non-significant inverse correlation was found. Interobserver correlation was high with r = 0.96 (p < 0.001), r = 0.86 (p < 0.001) and r = 0.72 (p = 0.001) for RV EDV, ESV and EF, respectively. CT attenuation of the right atrium (RA) and right ventricle (RV) was 196.9 ± 75.3 and 217.5 ± 76.1 HU, respectively.

CONCLUSIONS: Measurement of RV function by CTA using a novel 3D volumetric segmentation tool is fast and reliable by applying a dedicated biphasic injection protocol. The RV EF from CTA is a closer surrogate of RAP than TAPSE by TTE.

KEY POINTS: • Evaluation of RV function by cardiac CTA by using a novel 3D volume segmentation tool is fast and reliable. • A biphasic contrast agent injection protocol ensures homogenous RV contrast attenuation. • Cardiac CT is a valuable alternative modality to CMR for the evaluation of RV function.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Burghard P, Plank F, Beyer C, et al. Evaluation of right ventricular function by coronary computed tomography angiography using a novel automated 3D right ventricle volume segmentation approach: a validation study. Eur Radiol. 2018. PMID: 29869175. doi:10.1007/s00330-018-5523-y

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。