全左心室覆盖与常规3层心肌灌注磁共振成像检测疑似冠状动脉疾病的比较
该前瞻性研究纳入30例疑似冠状动脉疾病并计划行冠状动脉造影的患者,在3.0 T下随机顺序接受全左心室覆盖(SW-CG-HYPR)与常规3层(SR-Turbo-FLASH)心肌灌注MRI,以X线造影狭窄≥50%为参考标准。SW-CG-HYPR图像质量评分更高(3.4±0.6 vs 3.0±0.7,p<0.05),患者水平敏感度94% vs 89%、特异度83% vs 75%、准确率90% vs 83%,血管水平AUC 0.96±0.02 vs 0.90±0.03(p<0.05)。结论认为全左心室覆盖心肌灌注MRI诊断准确率高于常规3层技术。
要点
- SW-CG-HYPR全左心室覆盖序列图像质量评分显著高于SR-Turbo-FLASH 3层序列(3.4±0.6 vs 3.0±0.7,p<0.05)。
- 患者水平检测CAD:SW-CG-HYPR敏感度94% vs SR-Turbo-FLASH 89%,特异度83% vs 75%,准确率90% vs 83%。
- 血管水平整体检测CAD的AUC:SW-CG-HYPR 0.96±0.02 vs SR-Turbo-FLASH 0.90±0.03(p<0.05)。
核心结论
- 全左心室覆盖心肌灌注MRI检测疑似CAD的诊断准确率高于常规3层技术。
研究设计与样本
- 前瞻性研究,连续纳入30例疑似CAD并计划行冠状动脉造影的患者,在3.0 T下按随机顺序接受SW-CG-HYPR全左心室覆盖与SR-Turbo-FLASH 3层心肌灌注MRI,由两名盲法观察者视觉判读灌注缺损,并与X线造影狭窄≥50%相关。
关键影像表现/征象
- SW-CG-HYPR图像质量评分为3.4±0.6,SR-Turbo-FLASH为3.0±0.7,前者显著更高(p<0.05)。
- 灌注缺损由两名盲法观察者视觉判读,并与X线造影狭窄≥50%进行相关分析。
诊断标准与关键数值
- 以X线冠状动脉造影狭窄≥50%为参考标准。
- 患者水平:SW-CG-HYPR敏感度94%、特异度83%、诊断准确率90%;SR-Turbo-FLASH敏感度89%、特异度75%、诊断准确率83%。
- 血管水平整体检测CAD的AUC:SW-CG-HYPR 0.96±0.02 vs SR-Turbo-FLASH 0.90±0.03(p<0.05)。
临床应用与阅片要点
- 判读心肌灌注MRI时,SW-CG-HYPR全左心室覆盖序列的图像质量评分高于SR-Turbo-FLASH 3层序列(3.4±0.6 vs 3.0±0.7,p<0.05)。
- 在疑似CAD患者中,SW-CG-HYPR的患者水平敏感度(94% vs 89%)、特异度(83% vs 75%)和诊断准确率(90% vs 83%)均高于SR-Turbo-FLASH。
- 血管水平整体检测CAD时,SW-CG-HYPR的AUC高于SR-Turbo-FLASH(0.96±0.02 vs 0.90±0.03,p<0.05)。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: Sliding-window conjugate-gradient highly constrained back-projection reconstruction (SW-CG-HYPR) allows whole left ventricular coverage, improved temporal and spatial resolution, and signal-to-noise ratio compared to the conventional 3-slice saturation recovery turbo-fast low-angle shot (SR-Turbo-FLASH) sequence. We prospectively compared the diagnostic value of whole leftventricular coverage myocardial perfusion magnetic resonance imaging (MRI) and conventional 3-slice technique in patients with suspected coronary artery disease (CAD).
MATERIALS AND METHODS: Thirty consecutive patients with suspected CAD who were scheduled for coronary angiography underwent myocardial perfusion MRI with both SW-CG-HYPR and SR-Turbo-FLASH in random order at 3.0 T. Perfusion defects were interpreted visually by two blinded observers and were correlated to x-ray angiographic stenoses ≥50%. Receiver-operating characteristic curve analysis was used to compare the diagnostic performance of the two imaging techniques.
RESULTS: The image quality score of SW-CG-HYPR was significantly higher than that of SR-Turbo-FLASH (3.4 ± 0.6 vs 3.0 ± 0.7, respectively; p < 0.05). In the per-patient analysis, SW-CG-HYPR provided a higher sensitivity (94% vs 89%), specificity (83% vs 75%), and diagnostic accuracy (90% vs 83%) for the detection of CAD than SR-Turbo-FLASH. In the per-vessel analysis, the diagnostic performance of SW-CG-HYPR was significantly greater than that of SR-Turbo-FLASH for the overall detection of CAD (area under receiver-operating characteristic curve: 0.96 ± 0.02 vs 0.90 ± 0.03, respectively; p < 0.05).
CONCLUSION: Whole left ventricular coverage myocardial perfusion MRI has higher diagnostic accuracy compared to conventional 3-slice technique for the detection of suspected CAD.
引用
- Ma H, Zhang Y, Chen J, et al. Whole Left Ventricular Coverage Versus Conventional 3-Slice Myocardial Perfusion Magnetic Resonance Imaging for the Detection of Suspected Coronary Artery Disease. Acad Radiol. 2018. PMID: 29887399. doi:10.1016/j.acra.2018.05.008
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。