文献速递心血管MR

3T非对比压缩感知全心冠状动脉磁共振血管成像与传统成像的比较

Non-contrast compressed sensing whole-heart coronary magnetic resonance angiography at 3T: A comparison with conventional imaging.
PubMed 文献 · Eur J Radiol · 2018-04-27

研究纳入20名健康志愿者,在3T临床磁共振扫描仪上无对比剂行压缩感知全心冠状动脉磁共振血管成像(MRA)与传统导航门控MRA,比较采集时间、图像质量和可视血管长度。压缩感知序列平均有效扫描时间3分45秒,显著短于传统的15分6秒;图像质量评分3.4±0.7低于传统3.8±0.4;作者结论为压缩感知可大幅缩短采集时间,同时在3T维持可接受的可视化。

要点

  • 压缩感知冠状动脉MRA平均有效扫描3分45秒,传统导航门控为15分6秒(p<0.001)。
  • 图像质量评分压缩感知3.4±0.7,低于传统3.8±0.4(p<0.0001)。
  • 压缩感知除右冠状动脉远段平均2.9分外,几乎各节段评分均>3.2,达诊断良好质量。

核心结论

  • 作者结论:使用压缩感知的非对比冠状动脉MRA相比传统导航门控冠状动脉MRA可大幅缩短采集时间,同时在3T维持可接受的可视化。

研究设计与样本

  • 研究为在临床3T磁共振扫描仪上无对比剂行冠状动脉MRA的对照研究,纳入20名健康志愿者。
  • 每名志愿者均接受压缩感知原型序列导航门控冠状动脉MRA与传统导航门控冠状动脉MRA。
  • 压缩感知空间分辨率为1.33×1.33×1.20 mm³,传统序列为1.33×1.33×1.48 mm³并插值至0.70×0.70×1.20 mm³。
  • 比较指标包括采集时间、4分制图像质量评分(右冠状动脉近中远段、左前降支主干及近中远段、左回旋支近远段)和三条血管的可视长度。

关键影像表现/征象

  • 平均接受率压缩感知冠状动脉MRA为44.9%,传统冠状动脉MRA为48.7%(p=0.39)。
  • 传统冠状动脉MRA各节段平均评分均>3.4,压缩感知冠状动脉MRA几乎各节段评分>3.2(诊断良好质量),仅右冠状动脉远段平均2.9分。
  • 右冠状动脉可视长度压缩感知11.5±4.4 cm vs 传统12.5±4.8 cm(p<0.05,95%一致性界限-3.6至1.6 cm)。
  • 左前降支可视长度压缩感知10.6±3.0 cm vs 传统11.1±2.9 cm(p=0.15,95%一致性界限-4.0至2.8 cm)。
  • 左回旋支可视长度压缩感知7.1±2.2 cm vs 传统8.2±2.5 cm(p<0.05,95%一致性界限-4.0至1.7 cm)。

诊断标准与关键数值

  • 图像质量采用4分制评分,原文将>3.2分界定为诊断良好质量。
  • 压缩感知冠状动脉MRA平均有效扫描时间3分45秒,传统冠状动脉MRA为15分6秒(p<0.001)。

临床应用与阅片要点

  • 作者结论提示压缩感知序列可大幅缩短非对比冠状动脉MRA采集时间,同时维持可接受的可视化,但压缩感知图像质量评分低于传统序列,右冠状动脉远段平均仅2.9分。

局限性

  • 研究对象为20名健康志愿者。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Whole-heart coronary magnetic resonance angiography (MRA) is a promising non-contrast, radiation-free technique for assessing the coronary artery. Yet, a disadvantage of coronary MRA is the relatively long acquisition time. The purpose of this study was to evaluate the scan time and image quality of compressed sensing (CS) coronary MRA compared with conventional coronary MRA.

MATERIALS AND METHODS: Twenty healthy volunteers underwent navigator-gated coronary MRA with a CS prototype sequence and conventional navigator-gated coronary MRA on a clinical 3T MRI scanner without contrast medium. The spatial resolutions were 1.33 × 1.33 × 1.20 mm3 for CS and 1.33 × 1.33 × 1.48 mm3 interpolated to 0.70 × 0.70 × 1.20 mm3 for conventional, respectively. We compared acquisition times, rated image quality on a 4-point scale (RCA; proximal, middle, and distal, LAD; main, proximal, middle, and distal, LCX; proximal and distal), and measured the visualized vessel lengths of three vessels.

RESULTS: The mean acceptance rates were 44.9% for CS coronary MRA and 48.7% for conventional coronary MRA (p = .39). The mean effective scan time was 3 min 45 s for CS coronary MRA and 15 min 6 s for conventional coronary MRA (p < 0.001). Image quality scores were significantly lower for CS coronary MRA than for conventional coronary MRA (3.4 ± 0.7 for CS vs. 3.8 ± 0.4 for conventional; p < 0.0001). Conventional coronary MRA images were scored >3.4 in all segments on average, while CS coronary MRA images were scored >3.2 (good quality for diagnosis) in almost all segments, with only the distal RCA segment graded 2.9 on average. The average visible vessel lengths for CS and conventional coronary MRA were as follows: 11.5 ± 4.4 cm and 12.5 ± 4.8 cm for the RCA, respectively (p < 0.05, 95% limits of agreement [LOA]; -3.6 to 1.6 cm); 10.6 ± 3.0 cm and 11.1 ± 2.9 cm for the LAD, respectively (p = .15, 95% LOA -4.0 to 2.8 cm); and 7.1 ± 2.2 cm and 8.2 ± 2.5 cm for the LCX, respectively (p < 0.05, 95% LOA -4.0 to 1.7 cm).

CONCLUSIONS: Non-contrast coronary MRA using CS could largely shorten acquisition time, compared with conventional navigator-gated coronary MRA, while maintaining acceptable visualization at 3T.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Nakamura M, Kido T, Kido T, et al. Non-contrast compressed sensing whole-heart coronary magnetic resonance angiography at 3T: A comparison with conventional imaging. Eur J Radiol. 2018. PMID: 29857865. doi:10.1016/j.ejrad.2018.04.025

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。