文献速递腹部介入胸部CTPET

CT引导下经皮粗针活检评估肺癌患者形态正常但FDG摄取增高的肾上腺

CT-guided percutaneous core biopsy for assessment of morphologically normal adrenal glands showing high FDG uptake in patients with lung cancer.
PubMed 文献 · Br J Radiol · 2018-07-25

该回顾性研究分析了2014年12月至2016年12月在本机构对肺癌患者形态正常但FDG摄取增高的肾上腺行CT引导下经皮粗针活检的5例患者共6次活检,其中5次(83.3%)证实为肺癌肾上腺转移,无并发症报告,患者术后次日出院,支持对这类肾上腺行CT引导下经皮活检以优化肺癌患者管理。

要点

  • 肺癌患者形态正常但FDG摄取增高的肾上腺,6次活检中5次(83.3%)证实为转移。
  • CT引导下经皮粗针活检采用俯卧位后路进针,17G同轴针配合18G自动切割针,无并发症报告。
  • 患者活检次日出院,支持对这类肾上腺行活检以指导肺癌治疗决策。

核心结论

  • 较高的转移确认率和无并发症支持对肺癌患者形态正常但FDG摄取增高的肾上腺行CT引导下经皮活检,以优化治疗管理。

研究设计与样本

  • 回顾性研究,纳入2014年12月至2016年12月在本机构因肺癌行肾上腺活检的5例患者共6次活检,目标为形态正常但FDG摄取增高的肾上腺;采用俯卧位后路进针,17G同轴针配合18G自动切割针;分析患者特征、操作细节、最终病理诊断及住院时间。

诊断标准与关键数值

  • 6次活检中5次(83.3%)病理证实为原发肺癌的肾上腺转移;未报告敏感度、特异度、AUC或阈值。

临床应用与阅片要点

  • 对肺癌患者形态正常但FDG摄取增高的肾上腺,CT引导下经皮粗针活检可确认转移;操作采用俯卧位后路进针、17G同轴针配合18G自动切割针,本研究中无并发症且患者次日出院。

局限性

  • 原文为回顾性研究,仅纳入5例患者共6次活检。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE:: Increased fludeoxyglucose (FDG) uptake in morphologically normal adrenal glands on positron emission tomography-CT (PET-CT) is a diagnostic challenge with major implications on treatment. The purpose of this retrospective study was to report our experience of CT-guided percutaneous core biopsy of morphologically normal adrenal glands showing increased FDG uptake in a context of lung cancer.

METHODS:: Biopsies for non-enlarged adrenal glands showing increased FDG uptake in lung cancer patients performed at our institution from December 2014 to December 2016 were retrospectively analyzed. Six biopsies were performed in five patients during the study period. All procedures were performed with the patients in the prone position, using a posterior approach and coaxial 17-gauge needles with 18-gauge automated cutting needles. Patient characteristics, procedural details and final pathological diagnosis were analyzed, as well as the duration of hospitalization.

RESULTS:: Five of the six biopsies (83.3%) confirmed adrenal metastasis from the primary lung cancer. No complications were reported and the patients were discharged the day after the procedure.

CONCLUSION:: The high confirmation rate of metastasis and lack of complications support performing CT-guided percutaneous biopsy of non-enlarged adrenal glands showing increased FDG uptake, for optimal management in lung cancer patients.

ADVANCES IN KNOWLEDGE:: Morphologically normal adrenal glands showing high FDG uptake in patients with lung cancer are metastasis. This manuscript shows that CT-guided percutaneous biopsy should be proposed. Increased FDG uptake in morphologically normal adrenal glands may indicate metastasis.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Chassagnon G, Bennani S, Freche G, et al. CT-guided percutaneous core biopsy for assessment of morphologically normal adrenal glands showing high FDG uptake in patients with lung cancer. Br J Radiol. 2018. PMID: 29906237. doi:10.1259/bjr.20180090

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。