文献速递骨肌CT

女性椎体模拟溶骨性缺损:基于CT的椎体强度结构分析

Female Human Spines with Simulated Osteolytic Defects: CT-based Structural Analysis of Vertebral Body Strength.
PubMed 文献 · Radiology · 2018-06-05

研究在11具女性尸体(年龄50-70岁)的44个三节段脊柱标本中制造溶骨性病灶,采用标准临床CT协议进行结构分析协议(SAP)预测失效载荷,并机械测试至失效。轴向压缩下CT SAP预测强度与胸段(r=0.84)和腰段(r=0.85)实测强度相关;压缩加扭转下相关性中等(r=0.66)。溶骨灶大小(28%-41%)与椎体强度无关。

要点

  • CT SAP预测轴向压缩下胸段和腰段椎体强度与实测值高度相关(r=0.84、0.85)。
  • 压缩加扭转下CT SAP预测强度与实测值中等相关(r=0.66)。
  • 骨密度与轴向压缩下腰段强度相关(r=0.64),与胸段相关(r=0.51)。

核心结论

  • CT SAP评估溶骨性病灶椎体强度与女性椎体实测强度相关。

研究设计与样本

  • 研究对11具女性尸体(年龄50-70岁)的44个胸腰椎三节段标本中段椎体制造溶骨性病灶,采用标准临床CT协议行CT SAP预测失效载荷,并机械测试至失效(纯轴向压缩或压缩加扭转),用线性回归评估缺损大小、骨密度和预测失效载荷与实测强度的关系。

诊断标准与关键数值

  • 轴向压缩下,CT SAP预测椎体强度与胸段实测强度相关(r=0.84;P<.001)。
  • 轴向压缩下,CT SAP预测椎体强度与腰段实测强度相关(r=0.85;P<.001)。
  • 压缩加扭转下,CT SAP预测强度与椎体实测强度中等相关(r=0.66;P=.018)。
  • 骨密度与腰段实测强度相关(r=0.64;P=.003),与胸段相关(r=0.51;P=.050)。
  • 压缩加扭转下,骨密度与脊柱强度不相关(胸段r=0.31,P=.539;腰段r=0.26,P=.610)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Purpose To evaluate a CT structural analysis protocol (SAP) for estimating the strength of human female cadaveric spines with lytic lesions. Materials and Methods Osteolytic foci was created in the middle vertebra of 44 thoracic and lumbar three-level segments from 11 female cadavers (age range, 50-70 years). The segments underwent CT by using standard clinical protocol and their failure strength was assessed at CT SAP. The spines were mechanically tested to failure in pure axial compression or in compression with torsion. The relationships of defect size, bone mineral density, and predicted failure load (at CT SAP) with measured vertebral strength were assessed with linear regression. Analysis of variance and Tukey test were used to evaluate the effect of region and mechanical test on spine strength. Results With axial compression, CT SAP predictions of vertebral strength correlated with the thoracic (r = 0.84; P < .001) and lumbar (r = 0.85; P < .001) segment-measured strength. Bone mineral density correlated with the lumbar (r = 0.64; P = .003) and thoracic (r, 0.51; P = .050) strength. At compression with torsion, CT SAP predictions of strength were moderately correlated with vertebral strength (r = 0.66; P = .018). At compression with torsion, bone mineral density was not correlated with spinal strength (thoracic and lumbar: r = 0.31 and r = 0.26, respectively; P = .539 and .610, respectively). The lytic focus size (range, 28%-41%) was not associated with vertebral strength. Conclusion CT SAP assessment of strength in vertebrae with lytic lesions correlated with the measured strength of female vertebral bodies. © RSNA, 2018 Online supplemental material is available for this article.

来源:Radiology,查看原文。版权归原作者所有。