囊性纤维化肺病的自动化计算机断层扫描评分

An automated computed tomography score for the cystic fibrosis lung.
PubMed 文献 · Eur Radiol · 2018-06-04

研究开发了一种基于密度的自动化CT评分,用于评估囊性纤维化患者高密度肺结构异常。在70例成人患者中,自动化评分与FEV1%pred的横断面相关性略低于视觉CF-CT评分(R最高-0.68 vs -0.72),但纵向随访相关性更高(R最高-0.61 vs -0.49)。基于Mode+3 SD和Mode+300 HU的自动化评分相关性最高,结论认为该评分能可靠量化高密度肺结构异常。

要点

  • 自动化CT密度评分与FEV1%pred呈中度至良好横断面相关(R最高-0.68)。
  • 纵向随访中自动化评分与FEV1%pred的相关性(R最高-0.61)高于视觉评分(R=-0.49)。
  • 基于Mode+3 SD和Mode+300 HU的自动化评分相关性最高,可能整合入标准报告流程。

核心结论

  • 所开发的CT密度评分能可靠量化囊性纤维化患者的高密度肺结构异常。

研究设计与样本

  • 研究纳入70例成人囊性纤维化患者;开发队列为17例接受ivacaftor治疗的患者,含45次治疗前及随访胸部CT;验证队列为53例未接受ivacaftor治疗的患者;计算基于固定和自适应阈值的CT密度评分并与视觉CF-CT评分比较。

诊断标准与关键数值

  • 自动化评分与FEV1%pred的横断面相关系数在开发队列和验证队列中分别为R最高-0.68和-0.61,视觉评分分别为R=-0.72和R=-0.64。
  • 纵向随访中自动化评分与FEV1%pred的相关系数R最高-0.61,视觉评分为R=-0.49。
  • 基于Mode+3 SD和Mode+300 HU的自动化评分横断面相关系数R=-0.59至-0.68,纵向相关系数R=-0.51至-0.61。

临床应用与阅片要点

  • 自动化CT评分可能整合入标准报告工作流程。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To develop an automated density-based computed tomography (CT) score evaluating high-attenuating lung structural abnormalities in patients with cystic fibrosis (CF).

METHODS: Seventy adult CF patients were evaluated. The development cohort comprised 17 patients treated with ivacaftor, with 45 pre-therapeutic and follow-up chest CT scans. Another cohort of 53 patients not treated with ivacaftor was used for validation. CT-density scores were calculated using fixed and adapted thresholds based on histogram characteristics, such as the mode and standard deviation. Visual CF-CT score was also calculated. Correlations between the CT scores and forced expiratory volume in 1 s (FEV1% pred), and between their changes over time were assessed.

RESULTS: On cross-sectional evaluation, the correlation coefficients between FEV1%pred and the automated scores were slightly lower to that of the visual score in the development and validation cohorts (R = up to -0.68 and -0.61, versus R = -0.72 and R = -0.64, respectively). Conversely, the correlation to FEV1%pred tended to be higher for automated scores (R = up to -0.61) than for visual score (R = -0.49) on longitudinal follow-up. Automated scores based on Mode + 3 SD and Mode +300 HU showed the highest cross-sectional (R = -0.59 to -0.68) and longitudinal (R = -0.51 to -0.61) correlation coefficients to FEV1%pred.

CONCLUSIONS: The developed CT-density score reliably quantifies high-attenuating lung structural abnormalities in CF.

KEY POINTS: • Automated CT score shows moderate to good cross-sectional correlations with FEV 1 %pred . • CT score has potential to be integrated into the standard reporting workflow.

来源:Eur Radiol,查看原文。版权归原作者所有。