胸部体层合成检测肺结节生长:使用模拟结节的人体观察者研究
研究用模拟结节(体积约100 mm³和300 mm³及增长版本,增长11%–252%)植入成对胸部体层合成图像,让观察者判断结节是否稳定,ROC分析显示AUC 0.65–1。AUC最低出现在两次检查结节相对重建平面位置不匹配时,结节大小和剂量水平也影响结果。研究提示胸部体层合成可用于检测肺结节生长,但精度受结节大小、剂量及位置与重建平面不匹配影响。
要点
- 胸部体层合成可检测模拟肺结节生长,AUC 0.65–1。
- 基线/随访结节相对重建平面位置不匹配时AUC最低。
- 结节大小和剂量水平影响生长检测精度。
核心结论
- 研究提示胸部体层合成可用于检测肺结节生长,结节大小、剂量水平及基线与随访检查中结节相对图像重建平面的位置不匹配可能影响精度。
研究设计与样本
- 人体观察者研究,使用模拟结节(体积约100 mm³和300 mm³及增长版本,增长11%–252%)植入成对胸部体层合成检查图像,部分病例模拟剂量降低,病例涵盖不同结节大小、剂量水平和结节相对重建平面的位置。
诊断标准与关键数值
- ROC分析AUC范围为0.65–1;AUC最低出现在两次检查结节相对重建平面位置不匹配时。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: Chest tomosynthesis has been suggested as a suitable alternative to CT for follow-up of pulmonary nodules. The aim of the present study was to investigate the possibility of detecting pulmonary nodule growth using chest tomosynthesis.
MATERIALS AND METHODS: Simulated nodules with volumes of approximately 100 mm3 and 300 mm3 as well as additional versions with increasing volumes were created. The nodules were inserted into images from pairs of chest tomosynthesis examinations, simulating cases where the nodule had either remained stable in size or increased in size between the two imaging occasions. Nodule volume growths ranging from 11% to 252% were included. A simulated dose reduction was applied to a subset of the cases. Cases differing in terms of nodule size, dose level, and nodule position relative to the plane of image reconstruction were included. Observers rated their confidence that the nodules were stable in size or not. The rating data for the nodules that were stable in size was compared to the rating data for the nodules simulated to have increased in size using ROC analysis.
RESULTS: Area under the curve values ranging from 0.65 to 1 were found. The lowest area under the curve values were found when there was a mismatch in nodule position relative to the reconstructed image plane between the two examinations. Nodule size and dose level affected the results.
CONCLUSION: The study indicates that chest tomosynthesis can be used to detect pulmonary nodule growth. Nodule size, dose level, and mismatch in position relative to the image reconstruction plane in the baseline and follow-up examination may affect the precision.
引用
- Söderman C, Johnsson ÅA, Vikgren J, et al. Detection of Pulmonary Nodule Growth with Chest Tomosynthesis: A Human Observer Study Using Simulated Nodules. Acad Radiol. 2018. PMID: 29903641. doi:10.1016/j.acra.2018.05.004
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。