文献速递神经MR

利用相邻像素相关特性提高难治性癫痫伴海马内侧硬化患者异常海马的对比噪声比

Using Correlative Properties of Neighboring Pixels to Enhance Contrast-to-Noise Ratio of Abnormal Hippocampus in Patients With Intractable Epilepsy and Mesial Temporal Sclerosis.
PubMed 文献 · Acad Radiol · 2018-06-12

本研究纳入18例确诊海马内侧硬化的成人患者,对其冠状位FLAIR基线图像用自定义算法处理生成增强图像,计算异常海马相对正常同侧白质的平均和最大CNR。增强图像的平均和最大CNR均显著高于基线图像(均p < 0.0001),正常灰质CNR无显著差异(p = 0.9375),且增强图像上异常信号识别信心更高(p = 0.0001)。

要点

  • 增强图像上异常海马的平均和最大CNR均显著高于基线图像(均p < 0.0001)。
  • 正常灰质CNR在基线图与增强图之间无显著差异(p = 0.9375)。
  • 增强图像上对海马信号异常的识别信心更高(p = 0.0001)。

核心结论

  • 图像处理可提高异常海马的CNR而不影响正常灰质的CNR,这种异常海马显示的选择性提高与更自信地识别海马信号异常相关。

研究设计与样本

  • 经机构审查委员会批准并符合健康保险流通与责任法案的研究,纳入18例确诊海马内侧硬化的成人(10例女性、8例男性,平均年龄41.2岁),对基线冠状位液体衰减反转恢复图像用自定义算法处理生成增强图像,以正常同侧白质为参照计算异常海马CNR。

诊断标准与关键数值

  • 异常海马平均CNR(Hmean)和最大CNR(Hmax)在增强图像上均显著高于基线图像(均p < 0.0001)。
  • 正常灰质CNR在基线图像与增强图像之间无显著差异(p = 0.9375)。
  • 一位对海马异常侧别设盲的神经放射科医师用五点量表(从肯定异常到肯定正常)评定海马信号强度,增强图像上识别异常的置信度更高(p = 0.0001)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: To test whether an image-processing algorithm can aid in visualization of mesial temporal sclerosis on magnetic resonance imaging by selectively increasing contrast-to-noise ratio (CNR) between abnormal hippocampus and normal brain.

MATERIALS AND METHODS: In this Institutional Review Board-approved and Health Insurance Portability and Accountability Act-compliant study, baseline coronal fluid-attenuated inversion recovery images of 18 adults (10 females, eight males; mean age 41.2 years) with proven mesial temporal sclerosis were processed using a custom algorithm to produce corresponding enhanced images. Average (Hmean) and maximum (Hmax) CNR for abnormal hippocampus were calculated relative to normal ipsilateral white matter. CNR values for normal gray matter (GM) were similarly calculated using ipsilateral cingulate gyrus as the internal control. To evaluate effect of image processing on visual conspicuity of hippocampal signal alteration, a neuroradiologist masked to the side of hippocampal abnormality rated signal intensity (SI) of hippocampi on baseline and enhanced images using a five-point scale (definitely abnormal to definitely normal). Differences in Hmean, Hmax, GM, and SI ratings for abnormal hippocampi on baseline and enhanced images were assessed for statistical significance.

RESULTS: Both Hmean and Hmax were significantly higher in enhanced images as compared to baseline images (p < 0.0001 for both). There was no significant difference in the GM between baseline and enhanced images (p = 0.9375). SI ratings showed a more confident identification of abnormality on enhanced images (p = 0.0001).

CONCLUSION: Image-processing resulted in increased CNR of abnormal hippocampus without affecting the CNR of normal gray matter. This selective increase in conspicuity of abnormal hippocampus was associated with more confident identification of hippocampal signal alteration.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Parsons MS, Sharma A, Hildebolt C, et al. Using Correlative Properties of Neighboring Pixels to Enhance Contrast-to-Noise Ratio of Abnormal Hippocampus in Patients With Intractable Epilepsy and Mesial Temporal Sclerosis. Acad Radiol. 2018. PMID: 29907398. doi:10.1016/j.acra.2018.05.007

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。