文献速递神经MR

采用自动MR配准融合法提高随访中新发多发性硬化病灶的检出

Improved Detection of New MS Lesions during Follow-Up Using an Automated MR Coregistration-Fusion Method.
PubMed 文献 · AJNR Am J Neuroradiol · 2018-06-07

这项前瞻性单中心研究纳入94例接受富马酸二甲酯治疗的多发性硬化患者,比较自动配准融合阅片法与标准滚动阅片法检出新高信号T2脑病灶的表现。配准融合法每例检出病灶数更多(7个 vs 4个,P<.001),检出至少1个新病灶的患者比例更高(59% vs 46%,P=.02),阅片时间缩短86秒(P<.001),读片信心更高(91% vs 40%,P<1×10⁻⁴)。

要点

  • 配准融合法每例检出新高信号T2病灶7个,标准滚动法4个(P<.001)。
  • 配准融合法检出至少1个新病灶的患者占59%,标准法占46%(P=.02)。
  • 配准融合法整体阅片时间快86秒(P<.001),读片信心91% vs 40%(P<1×10⁻⁴)。

核心结论

  • 自动配准融合法检出多发性硬化患者随访中新发高信号T2病灶的敏感度高于标准滚动阅片法,并缩短阅片时间;该方法可能有助于改善随访诊疗。

研究设计与样本

  • 前瞻性单中心研究,纳入2014年1月至2016年8月接受富马酸二甲酯治疗的94例多发性硬化患者(平均年龄38.9岁),由1名高年资神经放射科医师和1名低年资放射科医师独立盲法阅片,两次阅片间隔3周,以第二位高年资神经放射科医师的共识阅片为参考标准。

诊断标准与关键数值

  • 配准融合法每例检出新高信号T2病灶7个,标准滚动法4个(P<.001)。
  • 配准融合法检出至少1个新高信号T2病灶的患者比例为59%,标准滚动法为46%(P=.02)。
  • 配准融合法整体阅片时间较标准滚动法快86秒(P<.001)。
  • 配准融合法读片信心为91%,标准滚动法为40%(P<1×10⁻⁴)。
  • 新高信号T2病灶计数的观察者间及观察者内一致性均为优(κ系数评估)。

临床应用与阅片要点

  • 作者认为自动配准融合法对检出多发性硬化随访中新发高信号T2病灶更敏感,并可缩短阅片时间,可能有助于改善随访诊疗。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: MR imaging is the key examination in the follow-up of patients with MS, by identification of new high-signal T2 brain lesions. However, identifying new lesions when scrolling through 2 follow-up MR images can be difficult and time-consuming. Our aim was to compare an automated coregistration-fusion reading approach with the standard approach by identifying new high-signal T2 brain lesions in patients with multiple sclerosis during follow-up MR imaging.

MATERIALS AND METHODS: This prospective monocenter study included 94 patients (mean age, 38.9 years) treated for MS with dimethyl fumarate from January 2014 to August 2016. One senior neuroradiologist and 1 junior radiologist checked for new high-signal T2 brain lesions, independently analyzing blinded image datasets with automated coregistration-fusion or the standard scroll-through approach with a 3-week delay between the 2 readings. A consensus reading with a second senior neuroradiologist served as a criterion standard for analyses. A Poisson regression and logistic and γ regressions were used to compare the 2 methods. Intra- and interobserver agreement was assessed by the κ coefficient.

RESULTS: There were significantly more new high-signal T2 lesions per patient detected with the coregistration-fusion method (7 versus 4, P < .001). The coregistration-fusion method detected significantly more patients with at least 1 new high-signal T2 lesion (59% versus 46%, P = .02) and was associated with significantly faster overall reading time (86 seconds faster, P < .001) and higher reader confidence (91% versus 40%, P < 1 × 10-4). Inter- and intraobserver agreement was excellent for counting new high-signal T2 lesions.

CONCLUSIONS: Our study showed that an automated coregistration-fusion method was more sensitive for detecting new high-signal T2 lesions in patients with MS and reducing reading time. This method could help to improve follow-up care.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Galletto Pregliasco A, Collin A, Guéguen A, et al. Improved Detection of New MS Lesions during Follow-Up Using an Automated MR Coregistration-Fusion Method. AJNR Am J Neuroradiol. 2018. PMID: 29880479. doi:10.3174/ajnr.A5690

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。