文献速递神经MR

分区放大斜多层与非分区放大斜多层扩散加权成像在颈髓中的应用

Zonally Magnified Oblique Multislice and Non-Zonally Magnified Oblique Multislice DWI of the Cervical Spinal Cord.
PubMed 文献 · AJNR Am J Neuroradiol · 2018-06-14

研究纳入了54名23-58岁受试者,在1.5T扫描仪上比较ZOOM-EPI与非ZOOM-EPI序列在颈髓扩散张量成像中的指标差异。ZOOM序列下平均扩散率、轴向扩散率和径向扩散率显著降低,各向异性分数显著升高,且变异性更小,SNR为22.84±7.59 vs 19.7±7.05但差异未达统计学显著,作者推荐在颈髓临床成像中优先使用ZOOM DTI。

要点

  • ZOOM序列颈髓DTI的各向异性分数较非ZOOM序列显著升高,扩散率指标显著降低。
  • ZOOM序列DTI值变异性小于非ZOOM序列,图像精度更高。
  • ZOOM序列SNR为22.84±7.59,非ZOOM为19.7±7.05,差异未达统计学显著。

核心结论

  • ZOOM DTI采集方法在图像质量和精度上优于非ZOOM技术,作者推荐在颈髓临床成像中优先于常规全FOV单次激发EPI DTI使用。

研究设计与样本

  • 研究纳入54名23-58岁受试者(9名直接年龄匹配和45名间接年龄匹配),使用1.5T扫描仪进行ZOOM和非ZOOM DTI采集,计算各向异性分数、平均扩散率、轴向扩散率和径向扩散率,并在各椎间盘水平进行比较。

诊断标准与关键数值

  • 直接年龄匹配组中,ZOOM序列较非ZOOM序列平均扩散率显著降低(P=.05),轴向扩散率显著降低(P=.002),径向扩散率显著降低(P<.001),各向异性分数显著升高(P=.04)。
  • 间接年龄匹配组中,ZOOM序列较非ZOOM序列各向异性分数显著升高(P=.03),平均扩散率显著降低(P=.002),轴向扩散率显著降低(P<.001),径向扩散率显著降低(P=.002)。
  • ZOOM序列SNR为22.84±7.59,非ZOOM序列为19.7±7.05,采用假定方差不等双尾t检验时差异未达统计学显著。

临床应用与阅片要点

  • 作者推荐在颈髓临床成像中优先使用ZOOM DTI采集而非常规全FOV单次激发EPI DTI。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: The zonally magnified oblique multislice EPI (ZOOM-EPI) diffusion-weighted sequence has been visually shown to provide superior MR diffusion image quality compared with the full-FOV single-shot EPI sequence (non-ZOOM-EPI) in the adult cervical spinal cord. The purpose of this study was to examine the diffusion tensor imaging indices in the normal human cervical spinal cord between ZOOMED and non-ZOOMED DTI acquisitions and determine whether DTI values are comparable between direct and indirect age-matched groups.

MATERIALS AND METHODS: Fifty-four subjects 23-58 years of age (9 direct age-matched and 45 indirect age-matched) were scanned using a 1.5T scanner. Diffusion tensor indices including fractional anisotropy, mean diffusivity, axial diffusivity, and radial diffusivity were generated from the DTI dataset. These DTI values were calculated for both ZOOM and non-ZOOM acquisitions and compared at each intervertebral disc level. The variability of the DTI values for ZOOM and non-ZOOM sequences was measured using a coefficient of variation within direct and indirect age-matched controls.

RESULTS: The mean diffusivity, axial diffusivity, and radial diffusivity values obtained along the cervical spinal cord in the age-matched controls showed a significant decrease using the ZOOM sequence (P = .05, P = .002, and P < .001). Mean fractional anisotropy showed a significant increase (P = .04) using the ZOOM sequence. The indirect age-matched controls showed a statistically significant increase in fractional anisotropy (P = .03) and a decrease in mean diffusivity (P = .002), axial diffusivity (P < .001), and radial diffusivity (P = .002) using the ZOOM sequence. Less variability has been shown in DTI using the ZOOM sequence compared with the non-ZOOM sequence in both direct and indirect age groups. The ZOOM sequence exhibited higher SNR (SNRZOOM = 22.84 ± 7.59) compared with the non-ZOOM sequence (SNRnon-ZOOM = 19.7 ± 7.05). However, when we used a 2-tailed t test assuming unequal variances, the ZOOM sequence did not demonstrate a statistically significant increase.

CONCLUSIONS: ZOOM DTI acquisition methods provide superior image quality and precision over non-ZOOM techniques and are recommended over conventional full-FOV single-shot EPI DTI for clinical applications in cervical spinal cord imaging.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Alizadeh M, Poplawski MM, Fisher J, et al. Zonally Magnified Oblique Multislice and Non-Zonally Magnified Oblique Multislice DWI of the Cervical Spinal Cord. AJNR Am J Neuroradiol. 2018. PMID: 29903926. doi:10.3174/ajnr.A5703

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。