颅内动脉瘤壁强化与动脉瘤破裂相关:系统综述与荟萃分析

Intracranial Aneurysm Wall Enhancement Associated with Aneurysm Rupture: A Systematic Review and Meta-analysis.
PubMed 文献 · Acad Radiol · 2018-06-13

该系统综述与荟萃分析纳入5项研究共492例受试者,评估磁共振血管壁成像上动脉瘤壁强化(AWE)与动脉瘤破裂的关联。结果显示AWE与动脉瘤破裂呈显著正相关(OR 34.26,95%CI 10.20-115.07,p<0.001),无显著异质性(I²=26%)或发表偏倚(p=1.000)。环形AWE与破裂的关联在小型动脉瘤(<7 mm)中显著(OR 26.12,95%CI 6.11-111.75,p<0.001),但在大型动脉瘤中有限(OR 0.56,95%CI 0.21-1.44,p=0.23)。

要点

  • AWE与动脉瘤破裂显著独立相关,OR 34.26(95%CI 10.20-115.07,p<0.001)。
  • 环形AWE与破裂的关联在<7 mm动脉瘤中显著(OR 26.12),大型动脉瘤中有限(OR 0.56,p=0.23)。
  • AWE可能成为预测动脉瘤行为、识别高危动脉瘤的影像标志物。

核心结论

  • 磁共振血管壁成像上的AWE与动脉瘤破裂显著且独立相关,可能成为预测动脉瘤行为、识别高危动脉瘤的有前景的影像标志物。

研究设计与样本

  • 系统综述与荟萃分析,纳入5项研究共492例受试者,检索评估AWE与动脉瘤破裂关联的研究,采用随机效应模型进行荟萃分析。

关键影像表现/征象

  • 磁共振血管壁成像上可见动脉瘤壁强化(AWE)。
  • 环形AWE与动脉瘤破裂的关联在小型动脉瘤(<7 mm)中显著,在大型动脉瘤中有限。

诊断标准与关键数值

  • AWE与动脉瘤破裂总体关联:OR 34.26(95%CI 10.20-115.07,p<0.001)。
  • 环形AWE与破裂关联的异质性:Q=21.23,p<0.001,I²=86%。
  • 小型动脉瘤(<7 mm)中环形AWE与破裂关联:OR 26.12(95%CI 6.11-111.75,p<0.001)。
  • 大型动脉瘤中环形AWE与破裂关联:OR 0.56(95%CI 0.21-1.44,p=0.23)。

临床应用与阅片要点

  • 作者认为AWE可能成为预测动脉瘤行为、识别高危动脉瘤的有前景的影像标志物。

局限性

  • 环形AWE与动脉瘤破裂的单独分析中存在显著异质性(Q=21.23,p<0.001;I²=86%)。
  • 环形AWE与破裂的关联在大型动脉瘤中有限(OR=0.56,95%CI 0.21-1.44,p=0.23)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: Aneurysm wall enhancement (AWE) on magnetic resonance vessel wall imaging has been proposed as an imaging marker of aneurysm wall inflammation and instability. We performed a systematic review and meta-analysis to summarize the association between AWE and aneurysm rupture.

MATERIALS AND METHODS: We performed a comprehensive literature search of studies evaluating the association between AWE and aneurysm rupture. We abstracted the following study data: study design, patient demographics, aneurysm characteristics, MRI protocols, and AWE assessment. We performed meta-analysis using a random-effects model. Study heterogeneity was assessed by using the Cochrane Q and I2 statistic, and publication bias was examined by using the Begg-Mazumdar test.

RESULTS: Five studies with 492 subjects met eligibility for systematic review. We found a significant positive overall association between AWE and aneurysm rupture, with an odds ratio (OR) of 34.26 (95% confidence interval [CI] 10.20-115.07, p < 0.001). No significant heterogeneity (Q = 5.38, p = 0.25; I2 = 26%) or publication bias (p = 1.000) was present. In the separate analysis of circumferential AWE and aneurysm rupture, we identified marked heterogeneity across studies (Q = 21.23, p < 0.001; I2 = 86%). Further subgroup analysis considering the effect of aneurysm size showed that the strength of association between circumferential AWE and aneurysm rupture was significant in small aneurysms (<7 mm), with an OR of 26.12 (95% CI 6.11-111.75, p < 0.001), but limited in large aneurysms (OR = 0.56, 95% CI [0.21, 1.44], p = 0.23).

CONCLUSION: AWE on magnetic resonance vessel wall imaging is significantly and independently associated with aneurysm rupture and may become a promising imaging marker to predict aneurysm behavior and identify high-risk aneurysms.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Wang X, Zhu C, Leng Y, et al. Intracranial Aneurysm Wall Enhancement Associated with Aneurysm Rupture: A Systematic Review and Meta-analysis. Acad Radiol. 2018. PMID: 29908979. doi:10.1016/j.acra.2018.05.005

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。