文献速递腹部技术与安全CT

小肠与大肠手术后吻合口漏:CT的诊断效能及腔内对比剂应用的重要性

Anastomotic Leaks After Small- and Large-Bowel Surgery: Diagnostic Performance of CT and the Importance of Intraluminal Contrast Administration.
PubMed 文献 · AJR Am J Roentgenol · 2018-04-09

研究纳入经手术确诊的吻合口漏患者59例与无吻合口漏对照48例,由两名放射科医师和两名住院医师独立判读术后CT。最敏感的征象为腹腔游离积液(95.3%),腔内对比剂外漏特异度达96.6%;使用腔内对比剂并到达吻合口时,所有判读者诊断效能均更高(一名判读者除外)。

要点

  • 腹腔游离积液是诊断吻合口漏最敏感的CT征象(95.3%)。
  • 腔内对比剂外漏对吻合口漏高度特异(96.6%)。
  • 腔内对比剂到达吻合口时CT诊断效能更高,阅片时应重视对比剂使用。

核心结论

  • 使用腔内对比剂时CT诊断效能最高,因此在该患者人群中细致、谨慎地使用腔内对比剂很重要。

研究设计与样本

  • 研究纳入因怀疑吻合口漏行术后CT检查的患者,吻合口漏组59例经手术确诊,对照组48例经再次手术或至少6个月临床随访无异常确认;两名放射科医师和两名放射科住院医师独立判读预设影像预测征象。

关键影像表现/征象

  • 腹腔游离积液是最敏感的影像预测征象(95.3%)。
  • 腔内对比剂外漏是高度特异的影像预测征象(96.6%)。
  • 腹腔游离气体与腔内对比剂外漏的观察者间一致性均为显著(κ=0.76)。

诊断标准与关键数值

  • 各判读者对手术确诊吻合口漏的总体诊断效能以ROC曲线下面积评估,范围为0.76至0.86。
  • 使用腔内对比剂且对比剂到达吻合口时,除一名判读者诊断效能不变外,其余所有判读者的诊断效能均更高。
  • 腹腔游离积液敏感度95.3%,腔内对比剂外漏特异度96.6%。

临床应用与阅片要点

  • 阅片时应关注腹腔游离积液与腔内对比剂外漏两个征象,后者特异度高。
  • 使用腔内对比剂并使其到达吻合口有助于提高CT对吻合口漏的诊断效能。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: The objective of our study was to evaluate the diagnostic performance of CT in the identification of anastomotic leaks.

MATERIALS AND METHODS: This was a study of patients who underwent bowel surgery and a subsequent postoperative CT examination performed specifically for investigating for an anastomotic leak. The study group included patients with surgically confirmed anastomotic leaks (n = 59), and the control group included patients without anastomotic leaks (n = 48) confirmed by either repeat surgery or uneventful clinical follow-up for at least 6 months. Two radiologists and two radiology residents independently reviewed each CT examination for specific CT findings from a set of predetermined imaging predictors. The sensitivity and specificity for each imaging predictor were calculated for each reader, and the interobserver agreement was calculated using the Cohen kappa coefficient. Diagnostic performance was assessed using ROC curve analysis.

RESULTS: The most sensitive imaging predictor was intraabdominal free fluid (95.3%). Leakage of intraluminal contrast agent was also a highly specific imaging predictor (96.6%). Substantial interobserver agreement was shown for intraabdominal free gas (κ = 0.76) and leakage of intraluminal contrast agent (κ = 0.76). Overall diagnostic performance in correctly identifying surgically confirmed leaks, as assessed by the area under the ROC curve, ranged from 0.76 to 0.86. Diagnostic performance was higher for all readers when intraluminal contrast agent was used and reached the anastomosis, with the exception of one reader, whose diagnostic performance remained unchanged.

CONCLUSION: Diagnostic performance of CT was highest when an intraluminal contrast agent was used. Meticulous and careful use of an intraluminal contrast agent is therefore important in this patient population.

来源:AJR Am J Roentgenol,查看原文。版权归原作者所有。

引用

  1. Samji KB, Kielar AZ, Connolly M, et al. Anastomotic Leaks After Small- and Large-Bowel Surgery: Diagnostic Performance of CT and the Importance of Intraluminal Contrast Administration. AJR Am J Roentgenol. 2018. PMID: 29629802. doi:10.2214/AJR.17.18642

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。