文献速递神经介入DSA

支架类型是否影响小型动脉瘤(<10 mm)远期随访中弹簧圈栓塞的结局

Does stent type impact coil embolization outcomes in extended follow-up of small-sized aneurysms (< 10 mm)?
PubMed 文献 · Neuroradiology · 2018-04-20

本研究纳入286例患者共312个小型未破裂囊状动脉瘤(<10 mm),在支架辅助弹簧圈栓塞后接受中期和远期随访监测,比较Enterprise、Neuroform与LVIS三种支架类型对再通的影响。结果显示,6个月随访时49个动脉瘤(15.7%)出现再通,宽颈(>4 mm)、栓塞时不完全闭塞和支架类型是中期再通的显著影响因素,LVIS支架在限制再通方面表现最佳。

要点

  • 小型未破裂动脉瘤支架辅助栓塞后6个月再通率为15.7%(49/312)。
  • 宽颈(>4 mm)、栓塞时不完全闭塞及支架类型是中期再通的显著影响因素。
  • LVIS支架在随访中限制再通的表现优于Enterprise或Neuroform支架。

核心结论

  • 除栓塞时闭塞状态和瘤颈大小外,支架类型可能影响小型动脉瘤支架辅助弹簧圈栓塞的随访结局;LVIS支架在限制再通方面表现最佳。

研究设计与样本

  • 队列研究,纳入286例患者共312个小型未破裂囊状动脉瘤(<10 mm),支架辅助弹簧圈栓塞后接受中期和远期随访监测;置入支架类型为Enterprise 192个、Neuroform 27个、LVIS 93个;回顾所有病历和影像学资料;采用二元logistic回归分析中期再通率及相关危险因素。

诊断标准与关键数值

  • 6个月随访时49个动脉瘤(15.7%)出现再通,其中轻度再通34个、重度再通15个;多因素分析显示宽颈动脉瘤(>4 mm)HR=2.362(p=0.017)、栓塞时不完全闭塞HR=2.949(p=0.002)及支架类型(p=0.048)为中期再通的显著影响因素;高血压(p=0.095)和栓塞密度≤30%(p=0.213)未达统计学显著;与Enterprise(HR=2.828)或Neuroform(HR=4.206)支架相比,LVIS支架结局更有利。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: Self-expandable stents have enabled endovascular treatment of wide-necked aneurysms (ordinarily viewed as technically prohibitive), with favorable outcomes. However, the impact of stent type on occlusive stability has not been adequately investigated. In small-sized unruptured saccular aneurysms, we generated estimates of stent-assisted coil embolization outcomes during follow-up monitoring. Stent type and other risk factors linked to recanalization were analyzed.

METHODS: A cohort of 286 patients harboring 312 small-sized unruptured aneurysms (< 10 mm) was subjected to mid-term and extended follow-up monitoring after stent-assisted coiling. Three types of stents (Enterprise, 192; Neuroform, 27; LVIS, 93) were deployed in this population; all medical records and radiologic data of which were reviewed. Mid-term recanalization rates and related risk factors were assessed using binary logistic regression analysis.

RESULTS: A total of 49 aneurysms (15.7%) displayed recanalization at 6 months postembolization, with 34 and 15 instances of minor and major recanalization, respectively. Multivariate analysis indicated that wide-necked aneurysms (> 4 mm) (HR = 2.362; p = 0.017), incomplete occlusion at time of coiling (HR = 2.949; p = 0.002), and stent type (p = 0.048) were significant factors in mid-term recanalization, whereas hypertension (p = 0.095) and packing density ≤ 30% (p = 0.213) fell short of statistical significance. Compared with Enterprise (HR = 2.828) or Neuroform (HR = 4.206) stents, outcomes proved more favorable with use of LVIS.

CONCLUSIONS: Above findings demonstrate that in addition to occlusive status at time of coil embolization and neck size, stent type may affect follow-up outcomes of stent-assisted coil embolization in small-sized aneurysms. LVIS (vs Enterprise or Neuroform stents) performed best during follow-up monitoring in terms of limiting recanalization.

来源:Neuroradiology,查看原文。版权归原作者所有。

引用

  1. Lee J, Cho YD, Yoo DH, et al. Does stent type impact coil embolization outcomes in extended follow-up of small-sized aneurysms (< 10 mm)? Neuroradiology. 2018. PMID: 29675589. doi:10.1007/s00234-018-2022-4

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。