文献速递儿科影像技术与安全US

超微血管成像、剪切波弹性成像与形态指数在小儿淋巴结分类中的诊断效能比较研究

Diagnostic performances of superb microvascular imaging, shear wave elastography and shape index in pediatric lymph nodes categorization: a comparative study.
PubMed 文献 · Br J Radiol · 2018-05-11

本研究回顾性评估45枚恶性淋巴瘤、72枚急性淋巴结炎及146枚正常淋巴结,比较超微血管成像血管指数、剪切波弹性成像弹性值与速度值及形态指数的诊断效能。鉴别淋巴瘤与正常淋巴结时,血管指数>15%的诊断准确率为95%,弹性值>17 kPa为99%。鉴别淋巴瘤与淋巴结炎时,血管指数15%、弹性值17 kPa、速度2.45 m/s、形态指数65%的诊断准确率分别为83%、87%、88%、68%。

要点

  • 剪切波弹性成像弹性值>17 kPa鉴别淋巴瘤与正常淋巴结的诊断准确率达99%。
  • 血管指数>15%鉴别淋巴瘤与正常淋巴结的诊断准确率为95%。
  • 鉴别淋巴瘤与急性淋巴结炎时剪切波弹性成像优于超微血管成像。

核心结论

  • 超微血管成像获得的血管指数与剪切波弹性成像对区分恶性淋巴瘤、急性淋巴结炎与正常淋巴结具有合理的诊断价值。
  • 与超微血管成像相比,剪切波弹性成像在区分恶性淋巴结与急性淋巴结炎方面可能更有效。

研究设计与样本

  • 回顾性研究,对淋巴结进行多参数评估。
  • 纳入经组织病理学诊断的恶性淋巴瘤淋巴结45枚、根据临床和实验室检查诊断的急性淋巴结炎淋巴结72枚及正常淋巴结146枚。
  • 采用灰阶超声计算形态指数(最短径与最长径之比的百分数),剪切波弹性成像测量弹性值与速度值,超微血管成像计算血管指数,并与正常淋巴结比较。

关键影像表现/征象

  • 恶性淋巴瘤与急性淋巴结炎鉴别时,超微血管成像血管指数最佳截断值为15%,剪切波弹性成像弹性值最佳截断值为17 kPa,速度最佳截断值为2.45 m/s(p < 0.001),形态指数最佳截断值为65%(p < 0.002)。

诊断标准与关键数值

  • 鉴别淋巴瘤与正常淋巴结:血管指数截断值>15%时诊断准确率为95%;弹性值截断值>17 kPa时诊断准确率为99%。
  • 鉴别淋巴瘤与急性淋巴结炎:血管指数15%、弹性值17 kPa、速度2.45 m/s(p < 0.001)及形态指数65%(p < 0.002)的诊断准确率分别为83%、87%、88%和68%。

临床应用与阅片要点

  • 超微血管成像血管指数可作为鉴别淋巴瘤与淋巴结炎以及淋巴结炎与正常淋巴结的新型多普勒参数。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To determine the diagnostic utility of a vascularity index via superb microvascular imaging in lymph nodes of children with malignant lymphoma and acute lymphadenitis compared to normal lymph nodes.

METHODS: We performed a retrospective study for multiparametric lymph node (LN) evaluation. Malignant lymphoma diagnosed via histopathological examination and lymph nodes receiving an acute lymphadenitis diagnosis based on clinical and laboratory findings constituted the study subgroups. We calculated a shape index [SI (percent of shortest to longest diameter)] using grayscale ultrasonography and elasticity and velocity values via shear wave elastography (SWE) as well as a vascularity index (VI) using superb microvascular imaging (SMI) for comparison with normal lymph nodes.

RESULTS: 45 lymph nodes diagnosed with malignant lymphoma, 72 lymph nodes diagnosed with acute lymphadenitis and 146 normal lymph nodes were evaluated. For differentiating lymphoma from normal lymph nodes, vascularity index cut-off values higher than 15% represented a diagnostic accuracy of 95%; cut-off elasticity values higher than 17 kPa exhibited a diagnostic accuracy of 99%. Optimal VI, elasticity, velocity and SI cut-off values in differentiating lymphoma from lymphadenitis were 15%, 17 kPa, 2.45 m sn-1 (p < 0.001) and 65% (p < 0.002) with calculated diagnostic accuracies of 83, 87, 88 and 68%, respectively.

CONCLUSION: Vascularity index values obtained via superb microvascular imaging and SWE would be reasonably useful in differentiating malignant lymphoma and acute lymphadenitis from normal LNs. SWE would be more efficient in distinguishing malignant lymph nodes from acute lymphadenitis compared with superb microvascular imaging. Advances in knowledge: Vascularity index by superb microvascular imaging would be a novel Doppler parameter in differentiating both lymphoma from lymphadenitis and also lymphadenitis from normal lymph nodes.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Bayramoglu Z, Caliskan E, Karakas Z, et al. Diagnostic performances of superb microvascular imaging, shear wave elastography and shape index in pediatric lymph nodes categorization: a comparative study. Br J Radiol. 2018. PMID: 29658771. doi:10.1259/bjr.20180129

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。