第三代双源CT脑颈动脉造影中先进虚拟单能重建技术的评估:低浓度对比剂可行性
前瞻性随机纳入65例脑颈动脉双能量CT血管造影患者,分为高浓度对比剂组(碘普罗胺370,32例)和低浓度对比剂组(碘地醇270,33例),重建传统单能(Mono)与先进单能(Mono+)40–100 keV图像及标准混合图像。低浓度组40 keV Mono+图像的客观CNR和主观评分与高浓度组混合图像相当(均p>0.05),提示Mono+可降低碘对比剂浓度。
要点
- 低浓度组40 keV Mono+图像CNR与高浓度组混合图像相当(p>0.05)。
- Mono+较Mono噪声降低、CNR更优。
- 低浓度组40 keV Mono+图像CNR最高。
核心结论
- Mono+重建技术可在脑颈动脉造影诊断中降低碘对比剂浓度。
研究设计与样本
- 前瞻性随机研究,连续纳入65例拟行脑颈动脉双能量CT血管造影的患者,高浓度对比剂组32例(63.7±9.7岁)使用碘普罗胺370,低浓度对比剂组33例(60.7±10.8岁)使用碘地醇270;重建传统单能(Mono)与Mono+ 40–100 keV(每10 keV间隔)图像及标准混合(Mixed,120 kVp等效)图像。
诊断标准与关键数值
- 低浓度组40 keV Mono+图像与高浓度组Mixed图像比较:颈总动脉CNR 83.7±24.5 vs 78.1±23.2,颈内动脉82.2±26.8 vs 76.8±24.1,大脑中动脉72.5±24.6 vs 70.6±19.2,均p>0.05;主观图像评分3.95±0.19 vs 3.83±0.35,p>0.05。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To investigate the feasibility of low-concentration contrast media (LC-CM) in cerebral and cervical dual-energy CT angiography (DE-CTA) using an advanced monoenergetic (Mono+) reconstruction technique.
METHODS: Sixty-five consecutive patients prospectively selected to undergo cerebral and cervical DE-CTA were randomised into two groups: 32 patients (63.7 ± 9.7 years) in the high-concentration contrast medium (HC-CM) group with iopromide 370 and 33 patients (60.7 ± 10.8 years) in the low-concentration contrast medium (LC-CM) group with iodixanol 270. Traditional monoenergetic (Mono) and Mono+ images from 40 to 100 keV levels (at 10-keV intervals) and the standard mixed (Mixed, 120 kVp equivalent) images were reconstructed. Subjective image quality parameters included the contrast-to-noise ratio (CNR) and objective image quality parameters were evaluated and compared between the two groups.
RESULTS: The 40-keV Mono+ images in the LC-CM group showed comparable objective CNR (common carotid arteries: 83.7 ± 24.5 vs. 78.1 ± 23.2; internal carotid arteries: 82.2 ± 26.8 vs. 76.8 ± 24.1; middle cerebral arteries: 72.5 ± 24.6 vs. 70.6 ± 19.2; all p > 0.05) and subjective image scores (3.95 ± 0.19 vs. 3.83 ± 0.35; p > 0.05) compared with Mixed images in the HC-CM group.
CONCLUSION: The Mono+ reconstruction technique could reduce the concentration of iodinated CM in the diagnosis of cerebral and cervical angiography.
KEY POINTS: • Mono+ shows decreased noise and superior CNR compared with Mono. • The 40-keV Mono+ images show the highest CNR in the LC-CM group. • The Mono+ reconstruction technique could reduce the concentration of iodinated CM.
引用
- Zhao L, Li F, Zhang Z, et al. Assessment of an advanced virtual monoenergetic reconstruction technique in cerebral and cervical angiography with third-generation dual-source CT: Feasibility of using low-concentration contrast medium. Eur Radiol. 2018. PMID: 29654560. doi:10.1007/s00330-018-5407-1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。