文献速递外周血管头颈US

超快超声成像评估颈动脉僵硬度:可行性与潜在影响因素

Carotid Artery Stiffness Assessment by Ultrafast Ultrasound Imaging: Feasibility and Potential Influencing Factors.
PubMed 文献 · J Ultrasound Med · 2018-04-19

研究对162例连续患者的442条颈动脉及66名健康志愿者的颈动脉行超快超声脉搏波速度(PWV)测量,每次采集在1分钟内完成;观察者内变异显示收缩前PWV平均差±SD为0.12±1.28 m/s、收缩末PWV为0.06±1.30 m/s;内膜中层厚度(IMT)与PWV正相关,IMT和斑块是预测超快PWV测量失败的重要独立因素。

要点

  • 超快PWV每次颈动脉采集可在1分钟内完成,观察者内变异收缩前为0.12±1.28 m/s、收缩末为0.06±1.30 m/s。
  • IMT小于1.5 mm时,超高频探头更常获得有效超快PWV测量(P < .05)。
  • IMT和斑块是预测超快PWV测量失败的重要独立因素(P < .001)。

核心结论

  • 超快PWV是评估颈动脉僵硬度的有效且易用方法;IMT和探头类型是影响能否获得超快PWV测量的因素。

研究设计与样本

  • 对162例连续患者(患者组)的442条颈动脉和66名健康志愿者(对照组)行超快超声PWV测量,110个颈动脉节段使用高频和超高频探头。

诊断标准与关键数值

  • 观察者内变异:收缩前PWV平均差±SD为0.12±1.28 m/s,收缩末PWV为0.06±1.30 m/s;IMT小于1.5 mm时超高频探头更常获得有效测量(P < .05)。

临床应用与阅片要点

  • 作者结论认为超快PWV是评估颈动脉僵硬度的有效且易用方法,IMT和探头类型影响测量获取。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To evaluate the feasibility of the ultrafast ultrasound pulsed wave velocity (PWV) for carotid stiffness assessment and potential influencing factors.

METHODS: Ultrafast PWV measurements of 442 carotid arteries in 162 consecutive patients (patient group) and 66 healthy volunteers (control group) were performed. High- and very high-frequency transducers were used in 110 carotid segments. The ultrafast PWVs at the beginning and end of systole were automatically measured. The correlations between the intima-media thickness (IMT) and ultrafast PWV and the equipment and carotid factors influencing the utility of ultrafast PWV were analyzed.

RESULTS: Each ultrafast PWV acquisition was completed within 1 minute. The intraobserver variability showed mean differences ± SD of 0.12 ± 1.28 m/s for the PWV before systole and 0.06 ± 1.30 m/s for the PWV at the end of systole. Ultrafast PWV measurements were more likely obtained with the very high- frequency transducer when the IMT was less than 1.5 mm (P < .05). A generalized linear mixed-effects model analysis showed that the very high-frequency transducer had a greater ability to obtain a valid carotid ultrafast PWV measurement with an IMT of less than 1.5 mm (P < .05). The IMT was positively correlated with the PWV before systole and at the end of systole (r = 0.207-0.771; all P < .05) in the control group, patient group, and carotid subgroup with an IMT of less than 1.5 mm. A multiple regression analysis showed that the IMT and plaque were important independent factors in predicting failure of the ultrafast PWV (P < .001).

CONCLUSIONS: The ultrafast PWV is an effective and user-friendly method for evaluating carotid stiffness. The IMT and transducer type are factors influencing the ability to obtain an ultrafast PWV measurement.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Pan FS, Yu L, Luo J, et al. Carotid Artery Stiffness Assessment by Ultrafast Ultrasound Imaging: Feasibility and Potential Influencing Factors. J Ultrasound Med. 2018. PMID: 29672890. doi:10.1002/jum.14630

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。