评估用于膝关节成像的加速3D SPACE序列:结合压缩感知与自由停止扫描模式
前瞻性纳入80例患者,在3T MRI上比较结合压缩感知与自由停止扫描模式的3D质子密度加权SPACE序列(3D-PD-CS-SPACE free-stop)与常规2D方案。自由停止模式因运动停止扫描后,图像质量随有效采集时间延长略升;与2D-PD-fs参考序列的病灶分析总体一致率96.25%–100%(Kappa 0.883–1,p<0.001)。作者结论认为该序列是标准2D-PD-fs方案的可靠替代,采集时间可接受。
要点
- 3D-PD-CS-SPACE自由停止序列图像质量:47/80例最佳、21/80例轻度受损、10/80例中度受损、2/80例严重受损。
- 29/80例因受试者运动触发自由停止模式停止扫描,有效采集时间延长后图像质量略有提升。
- 与2D-PD-fs参考方案病灶分析总体一致率96.25%–100%(Kappa 0.883–1,p<0.001)。
核心结论
- 3D-PD-CS-SPACE自由停止序列是标准2D-PD-fs方案的可靠替代,采集时间可接受。
研究设计与样本
- 前瞻性研究,80例患者,3T MRI,采用常规2D方案与3D-PD-CS-SPACE自由停止序列,参考标准为2D-PD-fs序列,由2名放射科医生评估。
关键影像表现/征象
- 3D-PD-CS-SPACE自由停止序列图像质量:47/80例最佳,21/80例轻度受损,10/80例中度受损,2/80例严重受损。
- 29/80例自由停止扫描模式因受试者运动停止3D-PD-CS-SPACE采集,有效采集时间延长后图像质量略有提升。
- 与带自由停止的3D-PD-CS-SPACE相比,无自由停止采集的图像质量:6/29例相同,13/29例轻度改善,8/29例改善且轮廓相同,2/29例改善且轮廓更锐利。
诊断标准与关键数值
- 病灶分析显示3D-PD-CS-SPACE自由停止与2D-PD-fs常规方案结果高度一致,总体一致率96.25%–100%,Cohen's Kappa 0.883–1,p<0.001。
临床应用与阅片要点
- 在临床膝关节MRI中,3D-PD-CS-SPACE自由停止序列可作为标准2D-PD-fs方案的替代,采集时间可接受。
- 当自由停止模式因运动触发停止后,延长有效采集时间可使图像质量略有提升。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To prospectively evaluate a prototypical 3D turbo-spin-echo proton-density-weighted sequence with compressed sensing and free-stop scan mode for preventing motion artefacts (3D-PD-CS-SPACE free-stop) for knee imaging in a clinical setting.
METHODS AND MATERIALS: 80 patients underwent 3T magnetic resonance imaging (MRI) of the knee with our 2D routine protocol and with 3D-PD-CS-SPACE free-stop. In case of a scan-stop caused by motion (images are calculated nevertheless) the sequence was repeated without free-stop mode. All scans were evaluated by 2 radiologists concerning image quality of the 3D-PD-CS-SPACE (with and without free-stop). Important knee structures were further assessed in a lesion based analysis and compared to our reference 2D-PD-fs sequences.
RESULTS: Image quality of the 3D-PD-CS-SPACE free-stop was found optimal in 47/80, slightly compromised in 21/80, moderately in 10/80 and severely in 2/80. In 29/80, the free-stop scan mode stopped the 3D-PD-CS-SPACE due to subject motion with a slight increase of image quality at longer effective acquisition times. Compared to the 3D-PD-CS-SPACE with free-stop, the image quality of the acquired 3D-PD-CS-SPACE without free-stop was found equal in 6/29, slightly improved in 13/29, improved with equal contours in 8/29, and improved with sharper contours in 2/29. The lesion based analysis showed a high agreement between the results from the 3D-PD-CS-SPACE free-stop and our 2D-PD-fs routine protocol (overall agreement 96.25%-100%, Cohen's Kappa 0.883-1, p < 0.001).
CONCLUSION: 3D-PD-CS-SPACE free-stop is a reliable alternative for standard 2D-PD-fs protocols with acceptable acquisition times.
引用
- Henninger B, Raithel E, Kranewitter C, et al. Evaluation of an accelerated 3D SPACE sequence with compressed sensing and free-stop scan mode for imaging of the knee. Eur J Radiol. 2018. PMID: 29685548. doi:10.1016/j.ejrad.2018.03.001
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。