双能CT诊断骨髓水肿的诊断效能:系统评价与Meta分析
该系统评价与Meta分析纳入12项研究(1901个病灶,450例患者),评估双能CT(DECT)检测骨髓水肿(BME)的敏感度和特异度。汇总敏感度为0.85(95%CI:0.78-0.90),汇总特异度为0.97(95%CI:0.92-0.98)。定性评估的敏感度0.85、特异度0.97,高于定量评估的敏感度0.84、特异度0.88;脊柱与附肢骨骼的诊断效能均优良。
要点
- DECT检测BME的汇总敏感度0.85、特异度0.97,诊断效能优良。
- 定性评估敏感度0.85、特异度0.97,优于定量评估的0.84、0.88。
- 使用锡滤过、≥2个图像平面、层厚<1 mm时敏感度趋于更高。
核心结论
- DECT对BME检测具有优良的敏感度和特异度;采用锡滤过、≥2个图像平面、0.5-1 mm层厚对急性期BME(≥24 h)进行定性评估,推荐用于更敏感的诊断。
研究设计与样本
- 系统评价与Meta分析,检索PubMed和EMBASE数据库,纳入12项研究(1901个病灶,450例患者),采用双变量模型和分层汇总受试者工作特征模型评估DECT对BME的总体诊断效能。
关键影像表现/征象
- DECT对BME检测的汇总敏感度为0.85(95%CI:0.78-0.90),汇总特异度为0.97(95%CI:0.92-0.98)。
- 定性评估DECT表现的敏感度为0.85、特异度为0.97;定量评估的敏感度为0.84、特异度为0.88。
- 脊柱的敏感度为0.84、特异度为0.98;附肢骨骼的敏感度为0.84、特异度为0.93。
诊断标准与关键数值
- DECT检测BME的汇总敏感度0.85(95%CI:0.78-0.90),汇总特异度0.97(95%CI:0.92-0.98)。
- 定性评估敏感度0.85、特异度0.97;定量评估敏感度0.84、特异度0.88。
- 脊柱敏感度0.84、特异度0.98;附肢骨骼敏感度0.84、特异度0.93。
临床应用与阅片要点
- 使用锡滤过、≥2个图像平面、层厚<1 mm时DECT检测BME的敏感度趋于更高。
- 超急性期BME(<24 h)的敏感度趋于更低。
- 对急性期BME(≥24 h),采用锡滤过、≥2个图像平面、0.5-1 mm层厚进行定性评估,推荐用于更敏感的诊断。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: The aim of this systematic review and meta-analysis was to assess the sensitivity and specificity of dual-energy CT (DECT) for the detection of bone marrow oedema (BME).
METHODS: An electronic search of the PubMed and EMBASE databases was conducted. Bivariate modelling and hierarchical summary receiver-operating characteristic modelling were performed to evaluate the overall diagnostic performance of DECT for BME. Subgroup analysis was performed according to the assessment type (qualitative vs. quantitative) and anatomical location (spine vs. appendicular skeleton). Meta-regression analyses were performed according to the subject, study, and DECT characteristics.
RESULTS: Twelve eligible studies (1901 lesions, 450 patients) were included. DECT exhibited a pooled sensitivity of 0.85 [95% confidence interval (CI): 0.78-0.90] and a pooled specificity of 0.97 (95% CI: 0.92-0.98) for BME detection. In addition, the diagnostic performance of qualitative assessment (sensitivity, 0.85; specificity, 0.97) was higher than that of quantitative assessment (sensitivity, 0.84; specificity, 0.88) of DECT findings. The diagnostic performance of DECT for the spine (sensitivity, 0.84; specificity, 0.98) and appendicular skeleton (sensitivity, 0.84; specificity, 0.93) were excellent. According to meta-regression analysis, the use of a tin filter, ≥ 2 image planes, and a slice thickness < 1 mm tended to exhibit higher sensitivity and hyperacute stage BME (< 24 h) tended to exhibit lower sensitivity.
CONCLUSIONS: These findings indicate that DECT has excellent sensitivity and specificity for BME detection. Qualitative assessment of DECT findings obtained using a tin filter, ≥ 2 image planes, and a 0.5-1-mm slice thickness in the acute stage BME (≥24 h) is recommended for more sensitive diagnosis.
KEY POINTS: • Overall, DECT is useful for the detection of BME (sensitivity, 85%; specificity-97%). • Qualitative assessment (sensitivity-85%; specificity-97%) is more accurate than quantitative assessment (sensitivity-84%; specificity-88%). • DECT showed excellent diagnostic performance for both the spine/appendicular skeleton (sensitivity-84%/84%; specificity-98%/93%).
引用
- Suh CH, Yun SJ, Jin W, et al. Diagnostic performance of dual-energy CT for the detection of bone marrow oedema: a systematic review and meta-analysis. Eur Radiol. 2018. PMID: 29679212. doi:10.1007/s00330-018-5411-5
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。