文献速递骨肌技术与安全MR

基于解剖标志的手动分割MRI评估普通人群骨骼肌脂肪含量与面积的观察者间及观察者内变异性

Inter- and intra-observer variability of an anatomical landmark-based, manual segmentation method by MRI for the assessment of skeletal muscle fat content and area in subjects from the general population.
PubMed 文献 · Br J Radiol · 2018-05-03

本研究在KORA-FF4队列的50名受试者中,采用基于解剖标志的手动分割方法在L3椎体水平多回波Dixon序列上量化骨骼肌质子密度脂肪分数(PDFF)和横截面积(CSA),观察者间与观察者内重复性均极佳(ICC 0.98–1.0),且不受年龄、性别、BMI、身高及内脏脂肪组织影响。

要点

  • 基于解剖标志的手动骨骼肌分割在L3水平测量PDFF和CSA的观察者间与观察者内ICC均达0.98–1.0。
  • 观察者间PDFF绝对差-0.2±0.5%、CSA绝对差31±44.7 mm²,重复性极高。
  • PDFF重复性独立于CSA(ICC 0.93–0.99),各肌肉 compartment 一致性均优。

核心结论

  • 基于解剖标志的手动骨骼肌分割量化MRI骨骼肌脂肪含量与面积具有高度可重复性,可能作为大型队列研究中肌脂肪变性和肌少症的稳健替代指标。

诊断标准与关键数值

  • 观察者间PDFF的ICC为0.99,CSA的ICC为0.98,绝对差分别为-0.2±0.5%和31±44.7 mm²,相对差分别为-2.6±6.4%和2.7±3.9%。
  • 观察者内PDFF的ICC为1.0,绝对差0.0±0.4%,相对差0.4%;CSA的ICC为1.0,绝对差5.5±25.3 mm²,相对差0.5%。
  • 所有一致性不依赖于年龄、性别、BMI、身高和内脏脂肪组织(ICC 0.96–1.0);PDFF重复性独立于CSA(ICC 0.93–0.99)。

临床应用与阅片要点

  • 作者认为基于解剖标志的手动骨骼肌分割可提供高度可重复的骨骼肌脂肪含量和面积量化,可能作为大型队列研究中肌脂肪变性和肌少症的稳健替代指标。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Changes in skeletal muscle composition, such as fat content and mass, may exert unique metabolic and musculoskeletal risks; however, the reproducibility of their assessment is unknown. We determined the variability of the assessment of skeletal muscle fat content and area by MRI in a population-based sample.

METHODS: A random sample from a prospective, community-based cohort study (KORA-FF4) was included. Skeletal muscle fat content was quantified as proton-density fat fraction (PDFF) and area as cross-sectional area (CSA) in multi-echo Dixon sequences (TR 8.90 ms, six echo times, flip angle 4°) by a standardized, anatomical landmark-based, manual skeletal muscle segmentation at level L3 vertebra by two independent observers. Reproducibility was assessed by intraclass correlation coefficients (ICC), scatter and Bland-Altman plots.

RESULTS: From 50 subjects included (mean age 56.1 ± 8.8 years, 60.0% males, mean body mass index 28.3 ± 5.2) 2'400 measurements were obtained. Interobserver agreement was excellent for all muscle compartments (PDFF: ICC0.99, CSA: ICC0.98) with only minor absolute and relative differences (-0.2 ± 0.5%, 31 ± 44.7 mm2; -2.6 ± 6.4% and 2.7 ± 3.9%, respectively). Intra-observer reproducibility was similarly excellent (PDFF: ICC1.0, 0.0 ± 0.4%, 0.4%; CSA: ICC1.0, 5.5 ± 25.3 mm2, 0.5%, absolute and relative differences, respectively). All agreement was independent of age, gender, body mass index, body height and visceral adipose tissue (ICC0.96-1.0). Furthermore, PDFF reproducibility was independent of CSA (ICC0.93-0.99). Conclusions: Quantification of skeletal muscle fat content and area by MRI using an anatomical landmark-based, manual skeletal muscle segmentation is highly reproducible. Advances in knowledge: An anatomical landmark-based, manual skeletal muscle segmentation provides high reproducibility of skeletal muscle fat content and area and may therefore serve as a robust proxy for myosteatosis and sarcopenia in large cohort studies.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Kiefer LS, Fabian J, Lorbeer R, et al. Inter- and intra-observer variability of an anatomical landmark-based, manual segmentation method by MRI for the assessment of skeletal muscle fat content and area in subjects from the general population. Br J Radiol. 2018. PMID: 29658780. doi:10.1259/bjr.20180019

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。