文献速递骨肌US

腕与手超声:小于2毫米临床相关解剖结构左右侧对比的可靠性

Wrist and Hand Ultrasound: Reliability of Side-to-Side Comparisons of Very Small (<2-mm) Clinically Relevant Anatomic Structures.
PubMed 文献 · J Ultrasound Med · 2018-04-24

前瞻性纳入41名健康志愿者,由2名肌骨放射科医生分别评估腕手部多个小于2毫米结构(如滑车、支持带、韧带、神经分支),左右侧对比的组内一致性κ=0.674(95%CI 0.57-0.78),组间一致性κ=0.935(95%CI 0.92-0.95),组内相关系数0.97(95%CI 0.96-0.98),结论认为健康对侧可作为实时肌骨超声评估小结构的参考。

要点

  • 组间一致性κ=0.935(95%CI 0.92-0.95),提示不同医师间左右侧对比判读高度一致。
  • 组内一致性κ=0.674(95%CI 0.57-0.78),同一医师重复判读一致性为中等至良好。
  • 所有结构平均厚度0.78±0.44 mm,总体变异系数9.8%±0.07%,支持对侧参考的稳定性。

核心结论

  • 在临床实践中,实时肌骨超声评估小于2毫米结构时,可将健康对侧作为参考。

研究设计与样本

  • 前瞻性研究,纳入41名健康志愿者,由2名肌骨放射科医生分次双侧评估;41次检查中重复10次(24%)以评估组内与组间一致性;采用非参数统计。

关键影像表现/征象

  • 评估结构包括食指和拇指第一环形滑车、第三指矢状束、伸肌与屈肌支持带、拇指尺侧副韧带、食指桡侧副韧带及正中神经和尺神经掌皮支。
  • 所有结构平均厚度±标准差为0.78±0.44 mm。

诊断标准与关键数值

  • 组内一致性κ=0.674(95%CI 0.57-0.78)。
  • 组间一致性κ=0.935(95%CI 0.92-0.95)。
  • 总体变异系数9.8%±0.07%,组内相关系数0.97(95%CI 0.96-0.98)。
  • 数据非正态分布(P > .001)。

临床应用与阅片要点

  • 作者结论认为,临床实践中实时肌骨超声评估小于2毫米结构时可用健康对侧作为参考。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: In ultrasound (US) examinations of clinically relevant very small structures of the wrist and hand, the healthy contralateral side can be used as a reference to identify subtle abnormalities. Intraindividual side-to-side variability must be minimal. The aim of this study was to assess the reliability of side-to-side US evaluations of very small structures of the wrist and hand.

METHODS: Forty-one healthy volunteers were prospectively studied. Small structures of the wrist and hand were evaluated bilaterally by 2 musculoskeletal radiologists in separate sessions. The first annular pulleys of the second finger and the thumb, sagittal band of the third finger, extensor and flexor retinacula, ulnar collateral ligament of the thumb, radial collateral ligament of the second finger, and palmar cutaneous branches of the median and ulnar nerves were considered. To assess intra- and inter-reader agreement, 10 of 41 (24%) examinations were repeated. Nonparametric statistics were used.

RESULTS: Data were not normally distributed (P > .001). Intra-reader agreement was κ = 0.674 (95% confidence interval [CI], 0.57-0.78), and inter-reader agreement was κ = 0.935 (95% CI, 0.92-0.95). The mean value ± SD for all of the structures was 0.78 ± 0.44 mm. The overall coefficient of variation was 9.8% ± 0.07%. The intraclass correlation coefficient was 0.97 (95% CI, 0.96-0.98).

CONCLUSIONS: In clinical practice, the healthy contralateral side can be used as a reference during a real-time musculoskeletal US evaluation of small (<2-mm) structures.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Rossi F, Romano N, Muda A, et al. Wrist and Hand Ultrasound: Reliability of Side-to-Side Comparisons of Very Small (<2-mm) Clinically Relevant Anatomic Structures. J Ultrasound Med. 2018. PMID: 29689624. doi:10.1002/jum.14635

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。