验证肌肉骨骼超声在实验性痛风滑膜炎评估中的作用
本研究在10只兔膝关节内注射单钠尿酸盐晶体诱导急性痛风,另3只注射赋形剂作为对照,于注射后24小时和72小时行B型和能量多普勒超声评估。超声可区分注射组与对照组的不同炎症表现,且滑膜增厚、滑膜内能量多普勒信号和关节整体膨胀分别与组织病理学总评分、CD31免疫组化阳性染色测定的组织血管化和组织白细胞介素-1β水平显著相关。结论认为超声是评估兔实验性痛风性关节炎滑膜炎症的有效方法。
要点
- 兔急性痛风模型注射单钠尿酸盐晶体后24小时和72小时,超声可区分注射组与对照组的炎症表现。
- 超声滑膜增厚与滑膜组织病理学总评分显著相关(r=0.47,p=0.0188)。
- 超声滑膜内能量多普勒信号与CD31免疫组化阳性染色测定的组织血管化显著相关(r=0.46,p=0.0172)。
核心结论
- 超声是评估兔实验性痛风性关节炎滑膜炎症的有效方法。
研究设计与样本
- 实验性研究,10只兔关节内注射单钠尿酸盐晶体诱导急性痛风,3只对照兔注射赋形剂;注射后24小时和72小时行B型和能量多普勒超声评估,72小时后处死全部兔。
关键影像表现/征象
- 超声可区分单钠尿酸盐晶体注射组与对照组在24小时和72小时的不同炎症表现,以及注射后24小时的单钠尿酸盐晶体相关表现。
诊断标准与关键数值
- 超声滑膜增厚与滑膜组织病理学总评分相关(r=0.47,p=0.0188);滑膜内能量多普勒信号与CD31免疫组化阳性染色测定的组织血管化相关(r=0.46,p=0.0172);关节整体膨胀与组织白细胞介素-1β水平相关(r=0.53,p=0.0078)。
临床应用与阅片要点
- 原文未据此给出临床推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
The objective of this study was to validate musculoskeletal ultrasound (US) in a rabbit model of acute gout. Acute gout was induced by intra-articular injection of monosodium urate (MSU) crystals in 10 rabbits; the 3 controls received vehicle. Rabbit knees were assessed by B-mode and power Doppler (PD) US 24 and 72 h after injections. After 72 h, all rabbits were euthanized. US discriminated between the MSU-injected and control groups with respect to the different inflammatory findings at both at 24 and 72 h and for MSU crystal-related findings after 24 h of injection. US synovial thickening, intra-synovial power Doppler signal and global joint distension significantly correlated with the synovial global histopathological score (r = 0.47, p = 0.0188), tissue vascularization measured by CD31 immunohistochemical-positive staining (r = 0.46, p = 0.0172) and tissue levels of interleukin-1β (r = 0.53, p = 0.0078), respectively. US is a valid method for assessment of synovial inflammation in experimental gouty arthritis in rabbits.
引用
- Naredo E, Medina JP, Pérez-Baos S, et al. Validation of Musculoskeletal Ultrasound in the Assessment of Experimental Gout Synovitis. Ultrasound Med Biol. 2018. PMID: 29703511. doi:10.1016/j.ultrasmedbio.2018.03.018
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。