美国放射学会甲状腺影像报告和数据系统中所用超声特征的观察者间变异性

Interobserver Variability of Sonographic Features Used in the American College of Radiology Thyroid Imaging Reporting and Data System.
PubMed 文献 · AJR Am J Roentgenol · 2018-04-27

本研究纳入92例患者100个甲状腺结节,由8名委员会认证放射科医生按ACR TI-RADS五类特征评估并给出活检建议,用Fleiss kappa统计变异性。除形状(κ=0.61)和大钙化(κ=0.73)为高度一致外,其余特征一致性为一般至中等,边缘和其他类型强回声灶最差(κ=0.25–0.39);基于医生当前实践的活检建议一致性一般(κ=0.22),应用ACR TI-RADS后为中等(κ=0.51)。作者认为边缘和除大钙化外的各类强回声灶判读变异性最高,建议进一步教育。

要点

  • 边缘和其他类型强回声灶的观察者间一致性最差(κ=0.25–0.39)。
  • 形状(κ=0.61)和大钙化(κ=0.73)的观察者间一致性为高度一致。
  • 基于医生当前实践的活检建议一致性一般(κ=0.22),应用ACR TI-RADS后为中等(κ=0.51)。

核心结论

  • 甲状腺结节超声特征判读中,边缘和除大钙化外的各类强回声灶变异性最高;尽管特征判读存在变异性,采用ACR TI-RADS可提高活检建议的一致性。

研究设计与样本

  • 研究队列为2009年4月至2010年5月间接受细针穿刺且细胞学结果明确(Bethesda II或VI类)或诊断性肺叶切除术的92例患者共100个结节;8名委员会认证放射科医生按构成ACR TI-RADS的五类特征评估结节,并基于各自当前实践给出活检建议;采用Fleiss kappa统计评估特征判读和活检建议的变异性。

诊断标准与关键数值

  • 除形状(κ=0.61)和大钙化(κ=0.73)为高度一致外,其余特征一致性为一般至中等;边缘和其他类型强回声灶的kappa值为0.25–0.39,为一般一致;基于放射科医生当前实践的活检建议观察者间一致性为一般(κ=0.22),应用ACR TI-RADS后为中等一致(κ=0.51)。

临床应用与阅片要点

  • 作者认为,由于放射科医生对这些特征的判读会改变甲状腺恶性肿瘤的怀疑程度,本研究结果提示需要进一步教育。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: The purpose of this study was to assess interobserver variability in assigning features in the American College of Radiology Thyroid Imaging Reporting and Data System (ACR TI-RADS) lexicon and in making recommendations for thyroid nodule biopsy.

MATERIALS AND METHODS: The study cohort comprised 100 nodules in 92 patients who underwent fine-needle aspiration with definitive cytologic results (Bethesda category II or VI) or diagnostic lobectomy between April 2009 and May 2010. Eight board-certified radiologists evaluated the nodules according to the five feature categories that constitute ACR TI-RADS and gave a biopsy recommendation based on their own practice. Variability in feature assignment and biopsy recommendation was assessed with the Fleiss kappa statistic.

RESULTS: Agreement in interpretation was fair to moderate for all features except shape (κ = 0.61) and macrocalcifications (κ = 0.73), which had substantial agreement. The features with the poorest agreement were margin and other types of echogenic foci, which had kappa values ranging from 0.25 to 0.39, indicating fair agreement. Interobserver agreement regarding biopsy recommendation was fair (κ = 0.22) based on radiologists' current practice. Applying ACR TI-RADS resulted in moderate agreement (κ = 0.51).

CONCLUSION: Variability in interpreting thyroid nodule sonographic features was highest for margin and all types of echogenic foci, except for macrocalcifications. Because radiologists' interpretations of these features change the level of suspicion of thyroid malignancy, the results of this study suggest a need for further education. Despite the variability in assigning features, adoption of ACR TI-RADS improves agreement for recommending biopsy.

来源:AJR Am J Roentgenol,查看原文。版权归原作者所有。

引用

  1. Hoang JK, Middleton WD, Farjat AE, et al. Interobserver Variability of Sonographic Features Used in the American College of Radiology Thyroid Imaging Reporting and Data System. AJR Am J Roentgenol. 2018. PMID: 29702015. doi:10.2214/AJR.17.19192