文献速递乳腺技术与安全MR

改善乳腺磁共振等待时间:将新实施的诊断影像检查过渡为常规临床运行的模型

Improving Breast MR Wait Times: A Model for Transitioning Newly Implemented Diagnostic Imaging Procedures into Routine Clinical Operation.
PubMed 文献 · J Am Coll Radiol · 2018-04-04

该质量改进项目于2014年12月至2016年3月开展,通过审查乳腺MR等待时间、排班表和人员配置找出等待时间升高的根本原因并实施整改。常规乳腺MRI等待时间从实施前的101天降至研究完成时的5天,技术重扫率为0.5%(4/798),图像质量损伤比例无显著变化(P=.69-.70),作者认为该模型可能有助于将其他专科诊断影像检查过渡为常规临床实践。

要点

  • 常规乳腺MRI等待时间从实施前101天降至研究完成时5天。
  • 技术重扫率为0.5%(4/798),无因技师相关错误或扫描质量担忧而重扫。
  • 轻度图像质量损伤占31%(99/320)、重度占3%(9/320),研究期间无显著变化(P=.69-.70)。

核心结论

  • 一项专科MR检查在保持图像质量的同时过渡为常规临床运行,该模型可能有助于将其他专科诊断影像检查过渡为常规临床实践。

研究设计与样本

  • 质量改进项目,2014年12月至2016年3月开展,研究期间共完成798例乳腺MR检查;对随机抽取的样本(每月20例,共320例)进行图像质量的回顾性分析;采用统计过程控制图和逻辑回归分析等待时间与图像质量数据。

诊断标准与关键数值

  • 图像质量损伤分为轻度(31%[99/320])与重度(3%[9/320]),研究期间该比例无显著变化(P=.69-.70);技术重扫率0.5%(4/798)。

临床应用与阅片要点

  • 作者认为该模型可能有助于将其他专科诊断影像检查过渡为常规临床实践。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: The purpose of this quality improvement (QI) initiative was to increase patient access to breast MR while maintaining diagnostic image quality.

METHODS: Institutional review board approval was waived for this HIPAA-compliant QI initiative, which was conducted from December 2014 through March 2016. Breast MR wait times, scheduling grids, and staffing models were reviewed to identify root causes of elevated wait times. Breast MR wait times were tracked on a biweekly basis as root causes were identified and action plans were implemented. Patient recall rates for repeat MR imaging were tracked. A retrospective analysis of image quality was performed in a randomly selected sample (20 per month; total: 320 examinations). Wait time and image quality data were analyzed with statistical process control charts and logistic regression.

RESULTS: In all, 798 breast MR examinations were performed during the study period. Monthly volume increased from 23 in December 2014 to 50 in March 2016 (range: 23-64). Wait time for a routine breast MRI fell from 101 days before implementation to 5 days at study completion. The technical recall rate was 0.5% (4 of 798); no recall was performed for a technologist-related error or scan quality concern. The proportion of examinations with minor (31% [99 of 320]) or major (3% [9 of 320]) image quality impairments did not significantly change during the study period (P = .69-.70).

CONCLUSION: A specialized MR examination was transitioned into routine clinical operation while maintaining image quality. This model may be useful for transitioning other specialized diagnostic imaging examinations into routine clinical practice.

来源:J Am Coll Radiol,查看原文。版权归原作者所有。

引用

  1. Neal CH, Sakala MD, Houck GE, et al. Improving Breast MR Wait Times: A Model for Transitioning Newly Implemented Diagnostic Imaging Procedures into Routine Clinical Operation. J Am Coll Radiol. 2018. PMID: 29625821. doi:10.1016/j.jacr.2018.02.004

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。