研究纳入126例早期乳腺癌患者,经皮内注射微泡后用经淋巴管对比增强超声(CEUS)检出164枚前哨淋巴结,并行CEUS引导细针穿刺(FNA)。126例中120例(95.24%)经SLN-FNA方法获得准确诊断,6例假阴性均因微转移或宏转移所致,术后组织病理学结果证实无假阳性。作者认为经淋巴管CEUS联合SLN-FNA创伤较小,术前评估腋窝淋巴结状态准确性高,可能有望成为与SLN活检同样可靠的腋窝淋巴结清扫指征。

要点

  • 经皮内注射微泡后CEUS可检出前哨淋巴结,本研究126例中共检出164枚。
  • CEUS引导FNA诊断SLN的准确率为95.24%(120/126例)。
  • 6例假阴性均由微转移或宏转移引起,术后病理证实无假阳性。

核心结论

  • 经淋巴管CEUS联合SLN-FNA是一种创伤较小的方法,术前评估腋窝淋巴结状态准确性高,可能有望成为与SLN活检同样可靠的腋窝淋巴结清扫指征。

研究设计与样本

  • 本研究为评估经淋巴管CEUS联合FNA术前评估早期乳腺癌腋窝淋巴结状态的研究,共126例,经皮内注射微泡后检出164枚前哨淋巴结,以术后组织病理学结果为参考标准。

关键影像表现/征象

  • 经皮内注射微泡后,CEUS共检出164枚前哨淋巴结,分布于126例病例中。

诊断标准与关键数值

  • CEUS引导SLN-FNA诊断准确率为95.24%(120/126例),6例假阴性均因微转移或宏转移,无假阳性。

临床应用与阅片要点

  • 作者认为经淋巴管CEUS联合SLN-FNA创伤较小,术前评估腋窝淋巴结状态准确性高,可能有望成为与SLN活检同样可靠的腋窝淋巴结清扫指征。

局限性

  • 6例假阴性均因微转移或宏转移所致。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

The purpose of this study was to assess whether translymphatic contrast-enhanced ultrasound (CEUS) combined with fine-needle aspiration (FNA) can be used pre-operatively to assess the status of axillary lymph nodes in early-stage breast cancer patients. Furthermore, we wanted to determine whether this less invasive method could potentially be a pre-operative surgical strategy. One hundred sixty-four sentinel lymph nodes (SLNs) were detected by CEUS after intradermal injection of microbubbles in 126 cases. One hundred twenty of 126 cases (95.24%) were accurately diagnosed with the SLN-FNA method. All 6 false-negative cases were due to micrometastasis or macrometastasis. There were no false-positive results after CEUS-guided FNA biopsy based on post-operative histopathological results. In conclusion, translymphatic CEUS combined with SLN-FNA is a less traumatic approach that has high accuracy in the pre-operative evaluation of axillary lymph node status. It might have the potential to be as reliable an indicator for axillary lymph node dissection as SLN biopsy.