文献速递妇产影像US

基于主成分分析利用二维和三维超声预测出生体重的新模型:中国人群研究

A New Model for Birth Weight Prediction Using 2- and 3-Dimensional Ultrasonography by Principal Component Analysis: A Chinese Population Study.
PubMed 文献 · J Ultrasound Med · 2018-03-30

该前瞻性研究对孕37-41周、分娩前7天内的正常单胎孕妇行二维和三维超声检查,共纳入1197例,分为建模组600例和验证组597例。采用主成分分析和逐步线性回归建立出生体重预测新模型,并与既往已发表公式比较,新模型在建模组和验证组的平均百分比误差及其标准差均降低,验证组100%的出生体重落在实际出生体重的10%以内。

要点

  • 孕37-41周分娩前7天内行二维和三维超声,测量9项指标可建立出生体重预测模型。
  • 建模组新模型平均百分比误差为3.661%±3.161%,优于既往公式。
  • 验证组新模型预测的出生体重100%落在实际出生体重10%以内。

核心结论

  • 基于主成分分析的二维和三维超声出生体重预测模型可能有助于提高估测胎儿出生体重的精度。

研究设计与样本

  • 前瞻性研究,对孕37-41周、分娩前7天内的正常单胎孕妇行二维和三维超声检查,共纳入1197例,分为建模组600例和验证组597例,采用主成分分析和逐步线性回归建立新预测模型,并以验证组与既往已发表公式比较确认准确性。

诊断标准与关键数值

  • 所有超声测量的组间和组内相关系数均大于0.75;从9项超声测量中提取出2个主成分用于确定估测胎儿出生体重;建模组新模型平均百分比误差为3.661%±3.161%;与既往已发表公式相比,新模型平均百分比误差至少降低47.558%,标准差降低57.421%;验证组结果与建模组相似,新模型覆盖100%的出生体重在实际出生体重10%以内。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To establish a new model for birth weight prediction using 2- and 3-dimensional ultrasonography (US) by principal component analysis (PCA).

METHODS: Two- and 3-dimensional US was prospectively performed in women with normal singleton pregnancies within 7 days before delivery (37-41 weeks' gestation). The participants were divided into a development group (n = 600) and a validation group (n = 597). Principal component analysis and stepwise linear regression analysis were used to develop a new prediction model. The new model's accuracy in predicting fetal birth weight was confirmed by the validation group through comparisons with previously published formulas.

RESULTS: A total of 1197 cases were recruited in this study. All interclass and intraclass correlation coefficients of US measurements were greater than 0.75. Two principal components (PCs) were considered primary in determining estimated fetal birth weight, which were derived from 9 US measurements. Stepwise linear regression analysis showed a positive association between birth weight and PC1 and PC2. In the development group, our model had a small mean percentage error (mean ± SD, 3.661% ± 3.161%). At least a 47.558% decrease in the mean percentage error and a 57.421% decrease in the standard deviation of the new model compared with previously published formulas were noted. The results were similar to those in the validation group, and the new model covered 100% of birth weights within 10% of actual birth weights.

CONCLUSIONS: The birth weight prediction model based on 2- and 3-dimensional US by PCA could help improve the precision of estimated fetal birth weight.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Liao S, Wang Y, Xiao S, et al. A New Model for Birth Weight Prediction Using 2- and 3-Dimensional Ultrasonography by Principal Component Analysis: A Chinese Population Study. J Ultrasound Med. 2018. PMID: 29603318. doi:10.1002/jum.14613

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。