弥散加权磁共振成像在诊断胎盘植入谱系异常中的价值
本研究纳入2013年7月至2015年7月间因疑似胎盘植入谱系异常或病理性粘连胎盘而行产前MRI的17例孕妇,比较仅T2加权序列与T2加权联合DWI序列对MAP的诊断效能。结果显示两者总体准确率(62.7% vs 68.6%,p=0.68)、敏感度(70.8% vs 95.8%,p=0.12)及特异度(55.6% vs 44.4%,p=0.49)均无显著差异,诊断信心亦无显著差异(7.3±1.8 vs 7.5±1.8,p=0.37),但DWI有助于改善胎盘-子宫肌层交界区异常的识别。
要点
- 疑似胎盘植入谱系异常时,T2WI联合DWI较单用T2WI未显著提高诊断准确率、敏感度或特异度。
- DWI有助于改善胎盘-子宫肌层交界区异常的识别。
- 联合DWI前后诊断信心评分无显著差异(7.3±1.8 vs 7.5±1.8,p=0.37)。
核心结论
- 在当前成像技术下,将DWI序列加入传统T2W图像未能显示可显著提高胎盘植入谱系异常诊断准确率或阅片者信心,但DWI确实改善了对胎盘-子宫肌层交界区异常的识别。
研究设计与样本
- 经当地伦理委员会批准的研究,纳入2013年7月至2015年7月间行产前MRI的孕妇,共17例,其中8例病理诊断为MAP。
关键影像表现/征象
- 所有成像均在Philips 1.5T MR扫描仪上使用盆腔相控阵线圈完成,仅汇编T2加权和DWI序列供审阅。
- 创建了两个随机化图像集:集1仅含T2加权序列(T2W),集2含T2W与DWI序列(T2W+DWI)。
- 三名对病史和病理不知情的放射科医生审阅图像,两次图像集审阅间隔2周。
诊断标准与关键数值
- MAP诊断总体准确率:T2W为62.7% vs T2W+DWI为68.6%,p=0.68。
- MAP诊断敏感度:T2W为70.8% vs T2W+DWI为95.8%,p=0.12。
- MAP诊断特异度:T2W为55.6% vs T2W+DWI为44.4%,p=0.49。
- 诊断信心评分:T2W为7.3±1.8 vs T2W+DWI为7.5±1.8,p=0.37。
临床应用与阅片要点
- 在疑似胎盘植入谱系异常的产前MRI阅片中,添加DWI序列未能显示可显著提高MAP诊断准确率或阅片者信心。
- DWI可改善对胎盘-子宫肌层交界区异常的识别。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: The aim of this study was to evaluate the utility of added DWI sequences as an adjunct to traditional MR imaging in the evaluation of abnormal placentation in patients with suspicion for placenta accreta spectrum abnormality or morbidly adherent placenta (MAP).
MATERIALS AND METHODS: The study was approved by local ethics committee. The subjects included pregnant women with prenatal MRI performed between July 2013 to July 2015. All imaging was performed on a Philips 1.5T MR scanner using pelvic phased-array coil. Only T2-weighted and diffusion-weighted imaging (DWI) series were compiled for review. Two randomized imaging sets were created: set 1 included T2-weighted series only (T2W); set 2 included T2W with DWI series together (T2W + DWI). Three radiologists, blinded to history and pathology, reviewed the imaging, with 2 weeks of time between the two image sets. Sensitivity, specificity, and overall accuracy for MAP were calculated and compared between T2W only and T2W + DWI reads. Associations between imaging findings and invasion on pathology were tested using the Chi-squared test. Confidence scores, inter-reader agreement, and systematic differences were documented.
RESULTS: A total of 17 pregnant women were included in the study. 8 cases were pathologically diagnosed with MAP. There were no significant differences in the diagnostic accuracy between T2W and T2W + DWI in the diagnosis of MAP in terms of overall accuracy (62.7% for T2W vs. 68.6% for T2W + DWI, p = 0.68), sensitivity (70.8% for T2W vs. 95.8% for T2W + DWI, p = 0.12), and specificity (55.6% for T2W vs. 44.4% for T2W + DWI, p = 0.49). There was no significant difference in the diagnostic confidence between the review of T2W images alone and the T2W + DWI review (mean 7.3 ± 1.8 for T2W vs. 7.5 ± 1.8 for T2W + DWI, p = 0.37).
CONCLUSION: With the current imaging technique, addition of DWI sequence to the traditional T2W images cannot be shown to significantly increase the accuracy or reader confidence for diagnosis of placenta accreta spectrum abnormality. However, DWI does improve identification of abnormalities in the placental-myometrial interface.
引用
- Sannananja B, Ellermeier A, Hippe DS, et al. Utility of diffusion-weighted MR imaging in the diagnosis of placenta accreta spectrum abnormality. Abdom Radiol (NY). 2018. PMID: 29666952. doi:10.1007/s00261-018-1599-8
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。