宫颈近端与远端组织回声强度定量超声分析在早产宫颈重塑中的价值
回顾性病例对照研究纳入177例16至26周单胎妊娠,比较宫颈长度小于2.5 cm组(102例)与正常宫颈长度组(75例)的宫颈近端和远端组织回声百分比差异。短宫颈组回声百分比为9.8±10.1,正常组为17.2±9.5(P<.0001),差异源于近端而非远端宫颈回声变化。
要点
- 短宫颈组近端宫颈回声百分比低于正常宫颈长度组,差异源于近端而非远端宫颈。
- 无论宫颈长度如何,近端宫颈回声强度均高于远端宫颈。
- 定量超声分析可检测中孕期宫颈近端与远端组织回声差异。
核心结论
- 定量超声分析可检测中孕期宫颈近端与远端组织回声差异;宫颈长度小于2.5 cm时近端宫颈回声百分比较正常宫颈长度降低。
研究设计与样本
- 回顾性病例对照研究,纳入177例16至26周单胎妊娠,经阴道超声测量宫颈长度,短宫颈组102例(<2.5 cm),正常宫颈长度组75例(≥2.5 cm);采用Floyd-Steinberg抖动算法将感兴趣区灰度像素转为二值图并计算回声百分比。
关键影像表现/征象
- 感兴趣区选取于宫颈近端和远端间质,包括前唇和后唇。
- 近端宫颈回声强度高于远端宫颈,此规律不受宫颈长度影响。
- 短宫颈组回声百分比为9.8±10.1,正常宫颈长度组为17.2±9.5。
诊断标准与关键数值
- 短宫颈组与正常宫颈长度组回声百分比差异有统计学意义(P<.0001)。
- 近端宫颈回声变化有统计学意义(P<.008),远端宫颈回声变化无统计学意义。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To determine whether a novel, noninvasive quantitative ultrasound (US) technique can detect differences in proximal and distal cervical tissue echogenicity in women with and without a shortened cervical length (CL).
METHODS: We conducted a retrospective case-control study of singleton pregnancies at 16 to 26 weeks' gestation in which a transvaginal US examination was performed to measure CL from 2013 to 2015. Initial CLs in cases and controls were less than 2.5 cm and 2.5 cm or greater, respectively. For each US image, a region of interest was selected in the proximal and distal cervical stroma, in both the anterior and posterior cervical lips. The Floyd-Steinberg dithering algorithm transformed grayscale pixels in each region of interest into a binary map. A histogram tabulated the number of black and white pixels, allowing determination of the percent echogenicity. The difference in the percent echogenicity was calculated by subtracting the distal cervical echogenicity (average of anterior and posterior lips) from the proximal cervical echogenicity (average of anterior and posterior lips).
RESULTS: Ultrasound images from 177 women were analyzed. There was a difference in the percent echogenicity (P < .0001) when comparing women with a short cervix (mean ± SD, 9.8 ± 10.1; n = 102) to women with a normal CL (17.2 ± 9.5; n = 75). Differences were attributable to changes in proximal (P < .008) rather than distal cervical echogenicity. Regardless of CL, the proximal cervix was more echogenic than the distal cervix.
CONCLUSIONS: A quantitative US analysis of cervical tissue can detect differences in echogenicity between the proximal and distal cervix in the second trimester. Proximal cervical echogenicity is lower with CL of less than 2.5 cm compared to a normal CL.
引用
- Blitz MJ, Ghorayeb SR, Pachtman SL, et al. Quantitative Ultrasound Analysis of Proximal and Distal Cervical Tissue Echogenicity in Premature Cervical Remodeling. J Ultrasound Med. 2018. PMID: 29663469. doi:10.1002/jum.14647
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。