三维磁共振骨盆测量:评估妊娠期女性骨盆的新技术
研究纳入301例足月妊娠女性,基于MRI数据用Mimics 10.0软件重建三维骨盆模型并测量骨盆径线,给出经阴道分娩组的骨盆测量参考值;采用既往CT三维骨盆测量预测头盆不称的方法验证,经阴道分娩组中67.6%(142/210)被诊断为头盆不称。作者认为三维MR骨盆测量是确定足月妊娠骨盆尺寸的新方法,需要前瞻性试验来确定其预测中国头盆不称高危女性头盆不称的有用价值。
要点
- 经阴道分娩组骨盆径线参考值:横径134.7 mm±7.5、产科结合径126.9 mm±8.3、棘间径113.4 mm±8.2。
- 经阴道分娩组中矢状中骨盆117.8 mm±8.1、结节间径127.1 mm±10.4、矢状出口110.2 mm±8.9、后矢状出口59.7 mm±8.1。
- 按既往CT三维骨盆测量预测头盆不称的方法,经阴道分娩组67.6%(142/210)被诊断为头盆不称。
核心结论
- 三维MR骨盆测量是确定足月妊娠骨盆尺寸的新方法,需要前瞻性试验来确定其预测中国头盆不称高危女性头盆不称的有用价值。
研究设计与样本
- 研究纳入301例足月妊娠接受MRI的孕妇,基于MRI数据集用Mimics 10.0软件重建三维骨盆模型并进行测量,按分娩方式呈现骨盆测量结果,并采用既往描述的CT三维骨盆测量预测头盆不称的方法验证其准确性。
诊断标准与关键数值
- 经阴道分娩组(210例)横径134.7 mm±7.5、产科结合径126.9 mm±8.3、棘间径113.4 mm±8.2。
- 经阴道分娩组矢状中骨盆117.8 mm±8.1、结节间径127.1 mm±10.4、矢状出口110.2 mm±8.9、后矢状出口59.7 mm±8.1。
- 按既往CT三维骨盆测量预测头盆不称的方法,经阴道分娩组67.6%(142/210)被诊断为头盆不称。
局限性
- 原文结论指出需要前瞻性试验来确定三维MR骨盆测量预测中国头盆不称高危女性头盆不称的有用价值。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To describe three-dimensional (3D) magnetic resonance imaging (MRI) pelvimetry methods and to establish the pelvimetric reference in a large population of Chinese females at term pregnancy.
METHODS: Three-hundred one pregnant women at term who underwent MRI were included. Three-dimensional pelvic models were reconstructed using Mimics. 10.0 software based on MRI data sets, and measurements of these models were made. Pelvimetric results according to delivery modality were presented. Additionally, the previously described CT 3D pelvimetry method for predicting cephalopelvic disproportion (CPD) was used to validate its accuracy.
RESULTS: Two hundred ten women underwent vaginal delivery, and 13 underwent caesarean delivery for CPD. 3D modelling of the pelvis of pregnant women was feasible using MR data sets. Pelvimetric parameters in the vaginal delivery group were as follows: transverse diameter, 134.7 mm ± 7.5; obstetric conjugate, 126.9 mm ± 8.3; interspinous distance, 113.4 mm ± 8.2; sagittal midpelvis, 117.8 mm ± 8.1; intertuberous distance, 127.1 mm ± 10.4; sagittal outlet, 110.2 mm ± 8.9, and posterior sagittal outlet, 59.7 mm ± 8.1. According to the previously described CT 3D pelvimetry method for predicting CPD, 67.6% (142/210) of women in the vaginal delivery group were diagnosed with CPD.
CONCLUSION: 3D MR pelvimetry is a novel method for determining pelvic dimensions at term pregnancy. A prospective trial is needed to establish a useful value for predicting CPD in Chinese females at high risk of CPD.
引用
- Liao KD, Yu YH, Li YG, et al. Three-dimensional magnetic resonance pelvimetry: A new technique for evaluating the female pelvis in pregnancy. Eur J Radiol. 2018. PMID: 29685537. doi:10.1016/j.ejrad.2018.03.024
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。